Robson Scoz

Dr. Robson Scoz

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2015 in Journal of Sport Rehabilitation
Verified
Journal Article
Closed access
CRCaroline Ruschel
Caroline Ruschel
AHAlessandro Haupenthal
Alessandro Haupenthal
GJGabriel Fernandes Jacomel
Gabriel Fernandes Jacomel
HFHeiliane de Brito Fontana
Heiliane de Brito Fontana
DSDaniela Pacheco dos Santos
Daniela Pacheco dos Santos
HRHelio Roesler
Helio Roesler
Context: Isometric muscle strength of knee extensors has been assessed for estimating performance, evaluating progress during physical training, and investigating the relationship between isometric and dynamic/functional performance. Objective: To assess the validity and reliability of an adapted leg-extension machine for measuring isometric knee extensor force. Design: Validity (concurrent approach) and reliability (test and test-retest approach) study. Setting: University laboratory. Participants: 70 healthy men and women aged between 20 and 30 y (39 in the validity study and 31 in the reliability study). Main Outcome Measures: Intraclass correlation coefficient (ICC) values calculated for the maximum voluntary isometric torque of knee extensors at 30°, 60°, and 90°, measured with the prototype and with an isokinetic dynamometer (ICC2,1, validity study) and measured with the prototype in test and retest sessions, scheduled from 48 h to 72 h apart (ICC1,1, reliability study). Results: In the validity analysis, the prototype showed good agreement for measurements at 30° (ICC2,1 = .75, SEM = 18.2 Nm) and excellent agreement for measurements at 60° (ICC2,1 = .93, SEM = 9.6 Nm) and at 90° (ICC2,1 = .94, SEM = 8.9 Nm). Regarding the reliability analysis, between-days' ICC1,1 were good to excellent, ranging from .88 to .93. Standard error of measurement and minimal detectable difference based on test-retest ranged from 11.7 Nm to 18.1 Nm and 32.5 Nm to 50.1 Nm, respectively, for the 3 analyzed knee angles. Conclusions: The analysis of validity and repeatability of the prototype for measuring isometric muscle strength has shown to be good or excellent, depending on the knee joint angle analyzed. The new instrument, which presents a relative low cost and easiness of transportation when compared with an isokinetic dynamometer, is valid and provides consistent data concerning isometric strength of knee extensors and, for this reason, can be used for practical, clinical, and research purposes.

30 August 2021 in BMJ Open Sport & Exercise Medicine
Verified
Journal Article
Open access
PDF file
RSRobson Scoz
Robson Scoz
CACesar Ferreira Amorim
Cesar Ferreira Amorim
TEThiago Espindola
Thiago Espindola
MSMateus Santiago
Mateus Santiago
JMJose Joao Baltazar Mendes
Jose Joao Baltazar Mendes
RBRomulo Nolasco Brito
Romulo Nolasco Brito
Objective To analyse rider’s subjective responses after a standardised bicycle ergonomic adjustment method. Methods Experimental study of 160 healthy, amateur mountain bikers analysed previously and 30 days after a bike-fitting session. The main outcome measures were subjective comfort level (Feeling Scale, FEEL), fatigue (OMINI Scale) and pain (Visual Analogue Scale, VAS). Results All variables demonstrated statistical significance between groups pre and post bike-fit session (p<0001). FEEL, OMNI and VAS-knee demonstrated large effect sizes (d=1.30; d=1.39 and d=0.86, respectively). VAS-hands, VAS-neck and VAS-back indicated moderate effect size (d=0.58; d=0.52 and d=0.43, respectively). VAS-groin and VAS-ankle indicated a small size effect (d=0.46 and d=0.43, respectively). Conclusions Overall discomfort, fatigue and pain in healthy mountain biker adults improved according to all three scales. The major improvements in pain levels were detected on the knee, hands, back and neck compared with presession values. Groin and ankle pain had smaller improvements but were still significant. Future clinical trials should address the bias effects of this experimental study.

21 November 2020 in BMJ Open Sport & Exercise Medicine
Verified
Journal Article
Open access
PDF file
RBRicardo Lima Burigo
Ricardo Lima Burigo
RSRobson Scoz
Robson Scoz
BABruno Mazziotti de Oliveira Alves
Bruno Mazziotti de Oliveira Alves
Rubens da SilvaRubens da Silva
Rubens da Silva
CMCésar Augusto Melo-Silva
César Augusto Melo-Silva
CACesar Ferreira Amorim
Cesar Ferreira Amorim
Background/Aim Different authors have tried to correlate the peak isokinetic torque values with the incidence of soccer match injuries. However, due to the wide variety of assessment testing protocols, such an inference becomes difficult. This study aimed to verify the capacity of an isokinetic test to establish injury risk reference values for hamstring strain injuries. Methods A retrospective cohort study based on isokinetic data and clinical records from the last 10 years was conducted in 582 Brazilian elite-professional soccer players, who were subjected to the same isokinetic test protocol, machine, and tester. A Multivariate Logistic Regression Analysis for Complex Data Sampling was used to generate injury risk statistical indexes. Results Multivariate regression analysis of both legs provided important data to identify the cut-off values of Concentric Peak Torque (181.82 Newton/*metres), Concentric Work (236.23 watts) and Concentric Power (130.11 joules). Conclusions The injury risk indexes indicate that an increase of just one Newton unit in CPT (Concentric Peak Torque) and CJ (Concentric Power) above those cut-off values, can reduce the risk of future injuries by 2% and 2.7%, respectively.

28 October 2024 in Interactive Journal of Medical Research
Verified
Journal Article
Open access
LCLaura Corrêa
Laura Corrêa
André JudiceAndré Judice
André Judice
RSRobson Scoz
Robson Scoz
Vanessa MachadoVanessa Machado
Vanessa Machado
José João MendesJosé João Mendes
José João Mendes
LUCIANO MAIA ALVES FERREIRALUCIANO MAIA ALVES FERREIRA
LUCIANO MAIA ALVES FERREIRA
Background: The concept of oral frailty has gained scientific and clinical relevance in recent years, and early detection can facilitate timely intervention to manage its progression. The Oral Frailty Index-8 (OFI-8) was developed to assess community-dwelling older adults at risk for oral frailty. Objective: This study aims to investigate the psychometric validity of the OFI-8 in the Portuguese population, named the Portuguese version of the OFI-8 (OFI-8-PT), which may serve as a reference for future studies related to longevity and oral function. Methods: This study included 2 main phases, involving patients aged 60 years or older, Portuguese speakers, and those who consented to participate in the study. First, the researchers translated and cross-culturally adapted the original questionnaire to make it suitable for native Portuguese speakers. The translated tool was then assessed for psychometric validation, which consisted of test-retest reliability, internal consistency, construct validity, and sex invariance measurement. Results: A total of 159 older adults participated in the baseline survey, with almost equal numbers of male (n=79, 49.7%) and female participants (n=80, 50.3%). The OFI-8-PT demonstrated good reliability (Cronbach α=0.95) and construct validity (goodness-of-fit index=0.96; comparative fit index=0.85; and root mean square error of approximation=0.05, 90% CI 0.00-0.09). The study found sex invariance, indicating that the OFI-8-PT is equally valid for male and female participants, and the tested-retest reliability of the OFI-8-PT was good, indicating consistent results over time. Conclusions: The OFI-8-PT showed psychometric validity and good reliability to be used in the Portuguese population.

30 June 2021 in Sensors
Verified
Journal Article
Open access
PDF file
RSRobson Scoz
Robson Scoz
TEThiago Roberto Espindola
Thiago Roberto Espindola
MSMateus Santiago
Mateus Santiago
POPaulo Rui de Oliveira
Paulo Rui de Oliveira
BABruno Mazziotti Oliveira Alves
Bruno Mazziotti Oliveira Alves
CACésar Ferreira Amorim
César Ferreira Amorim
Background: Kinematic analysis aimed toward scientific investigation or professional purposes is commonly unaffordable and complex to use. Objective: The purpose of this study was to verify concurrent validation between a cycling-specific 3D camera and the gold-standard 3D general camera systems. Methods: Overall, 11 healthy amateur male triathletes were filmed riding their bicycles with Vicon 3D cameras and the Retul 3D cameras for bike fitting analysis simultaneously. All 18 kinematic measurements given by the bike fitting system were compared with the same data given by Vicon cameras through Pearson correlation (r), intraclass correlation coefficients (ICC), standard error measurements (SEM), and Bland–Altman (BA) analysis. Confidence intervals of 95% are given. Results: A very high correlation between cameras was found on six of 18 measurements. All other presented a high correlation between cameras (between 0.7 and 0.9). In total, six variables indicate a SEM of less than one degree between systems. Only two variables indicate a SEM higher than two degrees between camera systems. Overall, four measures indicate bias tendency according to BA. Conclusions: The cycling-specific led-emitting 3D camera system tested revealed a high or very high degree of correlation with the gold-standard 3D camera system used in laboratory motion capture. In total, 14 measurements of this equipment could be used in sports medicine clinical practice and even by researchers of cycling studies.

RSRobson Scoz
Robson Scoz
POPaulo Rui de Oliveira
Paulo Rui de Oliveira
CSCleyton Santos
Cleyton Santos
JPJúlia Ribeiro Pinto
Júlia Ribeiro Pinto
CMCésar Augusto Melo-Silva
César Augusto Melo-Silva
CACésar Ferreira Amorim
César Ferreira Amorim
The purpose of this study is to analyze the long-term riders’ subjective responses to a standardized bikefitting method on their bicycles. Eighty-six amateur mountain bikers had their riding posture and bicycle components ergonomically adjusted through a 3D kinematic bikefitting method. Validated subjective scales (Feeling, OMNI, and Numerical Rating Pain Scale) were used to assess their overall riding comfort and fatigue along with localized pain for six body parts. Data were collected just before intervention (baseline or pre), immediately after (or post), and 30, 60, 90, and 120 days after the bikefit session. A Student’s t-test comparing before bikefit and after 120 days showed significant (p < 0.05) reduction in localized pain for all six body parts and riding comfort along with a large effect size effect (d = 1.18) for riding comfort. Although initially reduced, fatigue scores gradually increased over the months, showing a high correlation (r = 0.946) with increased monthly training volume. In conclusion, overall riding discomfort and pain were significantly decreased after a standardized kinematic bikefit session even after 120 days post intervention. However, fatigue scores began to rise after 30 days, showing a high correlation with increasing monthly training volume.