Haleigh Boswell

Ms. Haleigh Boswell


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2020 in Separations
Verified
Journal Article
Open access
PDF file
HBHaleigh Boswell
Haleigh Boswell
KCKieran Tarazona Carrillo
Kieran Tarazona Carrillo
TGTadeusz Górecki
Tadeusz Górecki
Historically, one-dimensional gas chromatography combined with mass spectrometry (GC/MS) has been employed in the analysis of petrochemical samples such as diesel, crude oil and bitumen. With increasingly complex samples, obtaining detailed information can be difficult with this method due to the large number of coelutions. By implementing comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GC×GC-TOFMS), the limitations of GC/MS can be overcome, due to the ability of this method to separate mixtures using two different separation mechanisms and obtain full mass spectra. Furthermore, this enables an investigation of biomarkers, compounds which aid in the identification of geological and environmental processes, potentially differentiating crude oil samples. Cryogenic-based thermal modulators are typically used for this application due to their superior focusing effect; however, some platforms require expensive cryogenic consumables. The solid-state modulator (SSM), a cryogen-free thermal platform, was employed for the first time for the group and biomarker analysis of Alberta oil sands bitumen. Evaluation of the SSM performance was based on published literature data on bitumen analysis. Extracted ion chromatograms (EIC) and molecular ion peaks were used for the confirmation of the groups’ and individual’s analytes. Identification of the characteristic biomarkers responsible for determining thermal maturity, source rock or oil origin was achieved. These results indicate the successful analysis of bitumen by consumable-free, solid-state modulation-based GC×GC-TOFMS.

11 December 2015 in Separations
Verified
Journal Article
Open access
PDF file
HBHaleigh Boswell
Haleigh Boswell
Frank L. DormanFrank L. Dorman
Frank L. Dorman
Analysis of blood alcohol concentration is a routine analysis performed in many forensic laboratories. This analysis commonly utilizes static headspace sampling, followed by gas chromatography combined with flame ionization detection (GC-FID). Studies have shown several “optimal” methods for instrumental operating conditions, which are intended to yield accurate and precise data. Given that different instruments, sampling methods, application specific columns and parameters are often utilized, it is much less common to find information on the robustness of these reported conditions. A major problem can arise when these “optimal” conditions may not also be robust, thus producing data with higher than desired uncertainty or potentially inaccurate results. The goal of this research was to incorporate the principles of quality by design (QBD) in the adjustment and determination of BAC (blood alcohol concentration) instrumental headspace parameters, thereby ensuring that minor instrumental variations, which occur as a matter of normal work, do not appreciably affect the final results of this analysis. This study discusses both the QBD principles as well as the results of the experiments, which allow for determination of more favorable instrumental headspace conditions. Additionally, method detection limits will also be reported in order to determine a reporting threshold and the degree of uncertainty at the common threshold value of 0.08 g/dL. Furthermore, the comparison of two internal standards, n-propanol and t-butanol, will be investigated. The study showed that an altered parameter of 85 °C headspace oven temperature and 15 psi headspace vial pressurization produces the lowest percent relative standard deviation of 1.3% when t-butanol is implemented as an internal standard, at least for one very common platform. The study also showed that an altered parameter of 100 °C headspace oven temperature and 15-psi headspace vial pressurization produces the lowest MDL of 0.00002 g/dL when n-propanol is implemented as an internal standard. These altered headspace parameters have the potential to produce more precise and accurate BAC determination.

5 April 2017 in Separations
Verified
Journal Article
Open access
PDF file
Frank L. DormanFrank L. Dorman
Frank L. Dorman
HBHaleigh Boswell
Haleigh Boswell
The original publication [1] was a short communication paper where a series of experiments were performed using a range of headspace oven temperatures and vial pressures to measure the resulting accuracy and precision of ethanol concentrations using headspace gas chromatography coupled to flame ionization detection (HS-GC-FID) analysis.