C. William Hanson

Prof. Dr. C. William Hanson

Anesthesiology and Critical Care at the Hospital of the University of Pennsylvania

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2005 in Anesthesiology
Verified
Journal Article
Closed access
C. William HansonC. William Hanson
C. William Hanson
ETErica R. Thaler
Erica R. Thaler
Background: The authors performed a prospective study to determine whether breath test analysis using an electronic nose correlates with a clinical pneumonia score. Methods: Exhaled gas was sampled from the expiratory limb of the ventilator in mechanically ventilated surgical intensive care patients and assayed with the electronic nose. Components of a clinical pneumonia score were recorded concurrently. Results: The score predicted by the electronic nose showed good correlation with the actual pneumonia score (r = 0.81). Bland Altman analysis showed a mean bias of 0.0 (limits +/- 2.6). Conclusions: The electronic nose is a new biosensor technology that correlates with a clinical pneumonia score.

Verified
Journal Article
Open access
PDF file
NPNiranjani Prasad
Niranjani Prasad
AMAishwarya Mandyam
Aishwarya Mandyam
CCCorey Chivers
Corey Chivers
MDMichael Draugelis
Michael Draugelis
C. William HansonC. William Hanson
C. William Hanson
Krzysztof LaudanskiKrzysztof Laudanski
Krzysztof Laudanski
Both provider- and protocol-driven electrolyte replacement have been linked to the over-prescription of ubiquitous electrolytes. Here, we describe the development and retrospective validation of a data-driven clinical decision support tool that uses reinforcement learning (RL) algorithms to recommend patient-tailored electrolyte replacement policies for ICU patients. We used electronic health records (EHR) data that originated from two institutions (UPHS; MIMIC-IV). The tool uses a set of patient characteristics, such as their physiological and pharmacological state, a pre-defined set of possible repletion actions, and a set of clinical goals to present clinicians with a recommendation for the route and dose of an electrolyte. RL-driven electrolyte repletion substantially reduces the frequency of magnesium and potassium replacements (up to 60%), adjusts the timing of interventions in all three electrolytes considered (potassium, magnesium, and phosphate), and shifts them towards orally administered repletion over intravenous replacement. This shift in recommended treatment limits risk of the potentially harmful effects of over-repletion and implies monetary savings. Overall, the RL-driven electrolyte repletion recommendations reduce excess electrolyte replacements and improve the safety, precision, efficacy, and cost of each electrolyte repletion event, while showing robust performance across patient cohorts and hospital systems.

29 January 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MPMargarete Pierce
Margarete Pierce
SGSteven Gudowski
Steven Gudowski
KRKarsten J. Roberts
Karsten J. Roberts
AJAnthony Jackominic
Anthony Jackominic
KZKaren K. Zumstein
Karen K. Zumstein
KLKrzysztof Laudanski
Krzysztof Laudanski
A 24/7 telemedicine respiratory therapist (eRT) service was set up as part of the established University of Pennsylvania teleICU (PENN E-LERT®) service during the COVID-19 pandemic, serving five hospitals and 320 critical care beds to deliver effective remote care in lieu of a unit-based RT. The eRT interventions were components of an evidence-based care bundle and included ventilator liberation protocols, low tidal volume protocols, tube patency, and an extubation checklist. In addition, the proactive rounding of patients, including ventilator checks, was included. A standardized data collection sheet was used to facilitate the review of medical records, direct audio–visual inspection, or direct interactions with staff. In May 2020, a total of 1548 interventions took place, 93.86% of which were coded as “routine” based on established workflows, 4.71% as “urgent”, 0.26% “emergent”, and 1.17% were missing descriptors. Based on the number of coded interventions, we tracked the number of COVID-19 patients in the system. The average intervention took 6.1 ± 3.79 min. In 16% of all the interactions, no communication with the bedside team took place. The eRT connected with the in-house respiratory therapist (RT) in 66.6% of all the interventions, followed by house staff (9.8%), advanced practice providers (APP; 2.8%), and RN (2.6%). Most of the interaction took place over the telephone (88%), secure text message (16%), or audio-video telemedicine ICU platform (1.7%). A total of 5115 minutes were spent on tasks that a bedside clinician would have otherwise executed, reducing their exposure to COVID-19. The eRT service was instrumental in several emergent and urgent critical interventions. This study shows that an eRT service can support the bedside RT providers, effectively monitor best practice bundles, and carry out patient–ventilator assessments. It was effective in certain emergent situations and reduced the exposure of RTs to COVID-19. We plan to continue the service as part of an integrated RT service and hope to provide a framework for developing similar services in other facilities.