Koji Fukudome

Dr. Koji Fukudome

Tokyo University of Science
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 August 2020 in Aerospace
Verified
Journal Article
Open access
PDF file
SUSho Uranai
Sho Uranai
Koji FukudomeKoji Fukudome
Koji Fukudome
HMHiroya Mamori
Hiroya Mamori
NFNaoya Fukushima
Naoya Fukushima
MYMakoto Yamamoto
Makoto Yamamoto
Ice accretion is a phenomenon whereby super-cooled water droplets impinge and accrete on wall surfaces. It is well known that the icing may cause severe accidents via the deformation of airfoil shape and the shedding of the growing adhered ice. To prevent ice accretion, electro-thermal heaters have recently been implemented as a de- and anti-icing device for aircraft wings. In this study, an icing simulation method for a two-dimensional airfoil with a heating surface was developed by modifying the extended Messinger model. The main modification is the computation of heat transfer from the airfoil wall and the run-back water temperature achieved by the heater. A numerical simulation is conducted based on an Euler–Lagrange method: a flow field around the airfoil is computed by an Eulerian method and droplet trajectories are computed by a Lagrangian method. The wall temperature distribution was validated by experiment. The results of the numerical and practical experiments were in reasonable agreement. The ice shape and aerodynamic performance of a NACA 0012 airfoil with a heater on the leading-edge surface were computed. The heating area changed from 1% to 10% of the chord length with a four-degree angle of attack. The simulation results reveal that the lift coefficient varies significantly with the heating area: when the heating area was 1.0% of the chord length, the lift coefficient was improved by up to 15%, owing to the flow separation instigated by the ice edge; increasing the heating area, the lift coefficient deteriorated, because the suction peak on the suction surface was attenuated by the ice formed. When the heating area exceeded 4.0% of the chord length, the lift coefficient recovered by up to 4%, because the large ice near the heater vanished. In contrast, the drag coefficient gradually decreased as the heating area increased. The present simulation method using the modified extended Messinger model is more suitable for de-icing simulations of both rime and glaze ice conditions, because it reproduces the thin ice layer formed behind the heater due to the runback phenomenon.

1 October 2016 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
DMDaichi Matsumoto
Daichi Matsumoto
Koji FukudomeKoji Fukudome
Koji Fukudome
HWHirofumi Wada
Hirofumi Wada
Understanding the hydrodynamic properties of fluid flow in a curving pipe and channel is important for controlling the flow behavior in technologies and biomechanics. The nature of the resulting flow in a bent pipe is extremely complicated because of the presence of a cross-stream secondary flow. In an attempt to disentangle this complexity, we investigate the fluid dynamics in a bent channel via the direct numerical simulation of the Navier-Stokes equation in two spatial dimensions. We exploit the absence of secondary flow from our model and systematically investigate the flow structure along the channel as a function of both the bend angle and Reynolds number of the laminar-to-turbulent regime. We numerically suggest a scaling relation between the shape of the separation bubble and the flow conductance, and construct an integrated phase diagram.

3 July 2020 in Aerospace
Verified
Journal Article
Open access
PDF file
TTToma Takahashi
Toma Takahashi
Koji FukudomeKoji Fukudome
Koji Fukudome
HMHiroya Mamori
Hiroya Mamori
NFNaoya Fukushima
Naoya Fukushima
MYMakoto Yamamoto
Makoto Yamamoto
Icing simulations involving super-cooled large droplets (SLDs) on a NACA0012 airfoil and a commercial axial fan were performed considering the characteristic behavior of SLD icing (i.e., splash-bounce, deformation, and breakup). The simulations were performed considering weak coupling between flow field and droplet motion. The flow field was computed using the Eulerian method, wherein the droplet motion was simulated via the Lagrangian method. To represent the ice shape, an extended Messinger model was used for thermodynamic computation. The ice shape and collection efficiency of the NACA0012 airfoil derived using the icing simulation exhibited a reasonable agreement with the existing experimental data. The icing simulation results for the axial fan, in terms of distribution of ice on the blade and its influence on the flow field, indicated that flow separation occurred, and the mass flow rate of the flow passage decreased. Moreover, the splash and bounce phenomena considerably influenced the icing process; however, the effect of the deformation and breakup phenomena was negligibly small. In terms of the effect of the SLDs on the icing phenomena, it was noted that, with the decrease in the SLD temperature (from −5 °C to −15 °C), the number of adhering SLDs increased, whereas the number of splashing and bouncing SLDs decreased.

16 October 2021 in Bioengineering
Verified
Journal Article
Open access
PDF file
YUYuya Uchiyama
Yuya Uchiyama
SFSoichiro Fujimura
Soichiro Fujimura
HTHiroyuki Takao
Hiroyuki Takao
TSTakashi Suzuki
Takashi Suzuki
MHMotoharu Hayakawa
Motoharu Hayakawa
MYMakoto Yamamoto
Makoto Yamamoto
Flow diverters (FDs) are widely employed as endovascular treatment devices for large or wide-neck cerebral aneurysms. Occasionally, overlapped FDs are deployed to enhance the flow diversion effect. In this study, we investigated the hemodynamics of overlapping FDs via computational fluid dynamics (CFD) simulations. We reproduced the arterial geometry of a patient who had experienced the deployment of two overlapping FDs. We utilized two stent patterns, namely the patterns for one FD and two overlapping FDs. We calculated the velocity, mass flow rate, wall shear stress, and pressure loss coefficient as well as their change rates for each pattern relative to the no-FD pattern results. The CFD simulation results indicated that the characteristics of the blood flow inside the aneurysm were minimally affected by the deployment of a single FD; in contrast, the overlapping FD pattern results revealed significant changes in the flow. Further, the velocity at an inspection plane within the aneurysm sac decreased by up to 92.2% and 31.0% in the cases of the overlapping and single FD patterns, respectively, relative to the no-FD pattern. The simulations successfully reproduced the hemodynamics, and the qualitative and quantitative investigations are meaningful with regard to the clinical outcomes of overlapped FD deployment.

1 November 2021 in World Neurosurgery
Verified
Journal Article
Open access
TITakumi Ishii
Takumi Ishii
SFSoichiro Fujimura
Soichiro Fujimura
HTHiroyuki Takao
Hiroyuki Takao
YUYuya Uchiyama
Yuya Uchiyama
TOTakuma Okudaira
Takuma Okudaira
YMYuichi Murayama
Yuichi Murayama
Coil compaction is directly related to the degree of cerebral aneurysmal recanalization. The degree of recanalization (DoR) was quantified by measuring the volume vacated by coil deformation. The purpose of this study was to clarify the hemodynamic and morphologic factors associated with coil compaction. Computational fluid dynamics simulations were performed on 28 middle-size (5-10 mm) unruptured basilar artery tip aneurysms. The DoR was measured by comparing the coil mass shape obtained from three-dimensional digital subtraction angiography data immediately after coil embolization and again within 1-2 years of follow-up. Deployed coils were modeled using a virtual coiling technique for computational fluid dynamics simulations. Hemodynamic and morphologic factors to predict the DoR were derived using multiple linear regression. Aneurysmal neck area, the maximum pressure generated on the neck surface after coil embolization, and the high-pressure position on the neck surface predicted DoR with statistic significance (P < 0.001, P < 0.001, P = 0.004, respectively). The DoR tended to increase when the neck area was large, the pressure generated on the coils was high, and the high-pressure position was close to the center of the neck surface. The volume embolization ratio was not statistically relevant for the DoR in the cases of this study. Coil compaction occurs in cerebral aneurysms with a wide neck, high pressure generated on the coils, and high pressure in the center of the neck surface. Establishing the DoR can contribute to the prediction of recanalization after coil embolization.

1 July 2018
Verified
Conference Paper
Closed access
KTKazutoshi Tanaka
Kazutoshi Tanaka
HTHiroyuki Takao
Hiroyuki Takao
TSTakashi Suzuki
Takashi Suzuki
SFSoichiro Fujimura
Soichiro Fujimura
YUYuya Uchiyama
Yuya Uchiyama
YMYuichi Murayama
Yuichi Murayama
Research on the relationship between cerebralaneurysm initiation and hemodynamic parameters, but several open questions remain on initiation and growth mechanisms of cerebral aneurysms. If factors contributing to initiation were identified, it would be possible to predict the initiation of aneurysms. The purpose of this study is to investigate the relationship between cerebral aneurysm initiation and hemodynamic factors. Blood flow simulations in aneurysms of three patients were performed using computational fluid dynamics (CFD) based on the cerebral blood vessel geometry before aneurysm initiation. We evaluated pressure, wall shear stress (WSS), wall shear stress gradient (WSSG), oscillatory shear index (OSI) and gradient oscillatory number (GON) since these factors are known to be associated with aneurysmal initiation. We also focused on the wall shear stress divergence (WSSD) in particular on the direction of WSS. Our results indicated that only high WSSD regions corresponded to the initiation regions, and the value of WSSD was remarkably high. Stretching force to the vessel wall may be related to the initiation of cerebral aneurysms.