Sunyoung Yoon

Ms. Sunyoung Yoon

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
HCHansol Chang
Hansol Chang
JYJaeYong Yu
JaeYong Yu
SYSunyoung Yoon
Sunyoung Yoon
SHSung Yeon Hwang
Sung Yeon Hwang
HYHee Yoon
Hee Yoon
TKTaerim Kim
Taerim Kim
(1) Background: During a pandemic, patients and processes in the emergency department (ED) change. These circumstances affect the length of stay (LOS) or degree of crowding in the ED. The processes for patients with acute critical illness, such as cerebrovascular disease (CVD), can be also delayed. Using the process mining (PM) method, this study aimed to evaluate LOS, ED processes for CVD, and delayed processes during the coronavirus disease 2019 (COVID-19) pandemic. (2) Methods: Data were collected from the Clinical Data Warehouse of a medical center. Phase 1 included patients who visited the ED before the COVID-19 outbreak. In Phase 2, post-COVID-19 ED patients were divided into the COVID-19 tested group (CTG) and COVID-19 not tested group (CNTG) according to whether polymerase chain reaction test was performed. We analyzed patients’ ED processes before and after COVID-19 using the PM method. We analyzed patients with acute CVD separately to determine whether the process and LOS of patients with acute critical illness were changed or delayed. (3) Results: After the COVID-19 outbreak, the overall LOS was delayed and all processes in CTG patients were delayed. Registration to triage and triage were delayed in both CTG and CNTG patients. The brain imaging process for CTG patients with acute CVD was also delayed. (4) Conclusion: After a pandemic, some processes were changed, new processes were developed, and processes for patients with acute CVD who needed proper time management were not exempted.

23 July 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SYSunyoung Yoon
Sunyoung Yoon
LDLothar Dieterich
Lothar Dieterich
CTCarlotta Tacconi
Carlotta Tacconi
MSMarko Sesartic
Marko Sesartic
YHYuliang He
Yuliang He
MDMichael Detmar
Michael Detmar
Podoplanin (PDPN) is a glycoprotein that is expressed by various cell types, including keratinocytes, fibroblasts, and lymphatic endothelial cells. We found that PDPN is expressed in the hair follicle (HF) keratinocyte region and HF stem cell area during the late anagen phase but not during the telogen phase in mice. Importantly, keratinocyte-specific PDPN deletion in mice (K5-Cre;PDPNflox/flox) promoted anagen HF growth after depilation-induced HF regeneration as compared to control mice. RNA sequencing, followed by gene ontology analysis, showed down-regulation of focal adhesion and extracellular matrix interaction pathways in HF stem cells isolated from K5-Cre;PDPNflox/flox mice as compared to control mice. Furthermore, HF keratinocytes isolated from K5-Cre;PDPNflox/flox mice exhibited a decreased ability to interact with collagen type I in cell adhesion assays. Taken together, these results show that PDPN deletion promotes HF cycling, possibly via reduced focal adhesion and concomitantly enhanced migration of HF stem cells towards the bulb region. They also indicate potential new therapeutic strategies for the treatment of conditions associated with hair loss.

1 April 2021 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
SYSunyoung Yoon
Sunyoung Yoon
TKTaerim Kim
Taerim Kim
TRTaehwan Roh
Taehwan Roh
HCHansol Chang
Hansol Chang
SHSung Yeon Hwang
Sung Yeon Hwang
WCWon Chul Cha
Won Chul Cha
Background: Cardiovascular disease is the leading cause of death worldwide. Early recognition, diagnosis, and reperfusion are the key elements of treatment for ST-segment elevation myocardial infarction. The absence of a prehospital 12-lead electrocardiogram (P12ECG) can cause definitive treatment delay and repeated transfer. Although guidelines highly recommend the measurement and transmission of P12ECG data, P12ECG use has not been widely established. Objective: The aim of this study was to verify the time-efficiency and feasibility of the use of a patchy-type 12-lead ECG measuring and transmitting device (P-ECG) by an emergency medical technician (EMT) in an ambulance during patient transport. Methods: This was a simulation-based prospective randomized crossover-controlled study that included EMTs. The participants were randomly assigned to one of two groups. Group A began the experiment with a conventional 12-lead ECG (C-ECG) device and then switched to the intervention device (P-ECG), whereas group B began the experiment with the P-ECG and then switched to the C-ECG. All simulations were performed inside an ambulance driving at 30 km/h. The time interval was measured from the beginning of ECG application to completion of sending the results. After the simulation, participants were administered the System Usability Scale questionnaire about usability of the P-ECG. Results: A total of 18 EMTs were recruited for this study with a median age of 35 years. The overall interval time for the C-ECG was 254 seconds (IQR 247-270), whereas the overall interval time for the P-ECG was 130 seconds (IQR 112-150), with a significant difference (P<.001). Significant differences between the C-ECG and P-ECG were identified at all time intervals, in which the P-ECG device was significantly faster in all intervals, except for the preparation interval in which the C-ECG was faster (P=.03). Conclusions: Performance of 12-lead ECG examination and transmission of the results using P-ECG are faster than those of C-ECG during ambulance transport. With the additional time afforded, EMTs can provide more care to patients and transport patients more rapidly, which may help reduce the symptoms-to-balloon time for patients with acute coronary syndrome. Trial Registration: ClinicalTrials.gov NCT04114760; https://www.clinicaltrials.gov/ct2/show/NCT04114760

5 September 2020 in JMIR Preprints
Verified
Preprint
Open access
SYSunyoung Yoon
Sunyoung Yoon
TKTaerim Kim
Taerim Kim
TRTaehwan Roh
Taehwan Roh
HCHansol Chang
Hansol Chang
SHSung Yeon Hwang
Sung Yeon Hwang
WCWon Chul Cha
Won Chul Cha
BACKGROUND Cardiovascular disease is the leading cause of death worldwide. Early recognition, diagnosis, and reperfusion are the key elements of treatment for ST-segment elevation myocardial infarction. The absence of a prehospital 12-lead electrocardiogram (P12ECG) can cause definitive treatment delay and repeated transfer. Although guidelines highly recommend the measurement and transmission of P12ECG data, P12ECG use has not been widely established. OBJECTIVE The aim of this study was to verify the time-efficiency and feasibility of the use of a patchy-type 12-lead ECG measuring and transmitting device (P-ECG) by an emergency medical technician (EMT) in an ambulance during patient transport. METHODS This was a simulation-based prospective randomized crossover-controlled study that included EMTs. The participants were randomly assigned to one of two groups. Group A began the experiment with a conventional 12-lead ECG (C-ECG) device and then switched to the intervention device (P-ECG), whereas group B began the experiment with the P-ECG and then switched to the C-ECG. All simulations were performed inside an ambulance driving at 30 km/h. The time interval was measured from the beginning of ECG application to completion of sending the results. After the simulation, participants were administered the System Usability Scale questionnaire about usability of the P-ECG. RESULTS A total of 18 EMTs were recruited for this study with a median age of 35 years. The overall interval time for the C-ECG was 254 seconds (IQR 247-270), whereas the overall interval time for the P-ECG was 130 seconds (IQR 112-150), with a significant difference (P<.001). Significant differences between the C-ECG and P-ECG were identified at all time intervals, in which the P-ECG device was significantly faster in all intervals, except for the preparation interval in which the C-ECG was faster (P=.03). CONCLUSIONS Performance of 12-lead ECG examination and transmission of the results using P-ECG are faster than those of C-ECG during ambulance transport. With the additional time afforded, EMTs can provide more care to patients and transport patients more rapidly, which may help reduce the symptoms-to-balloon time for patients with acute coronary syndrome. CLINICALTRIAL ClinicalTrials.gov NCT04114760; https://www.clinicaltrials.gov/ct2/show/NCT04114760