There are no published studies on the parameterisation and reliability of the single-leg stance (SLS) test with inertial sensors in stroke patients. Purpose: to analyse the reliability (intra-observer/inter-observer) and sensitivity of inertial sensors used for the SLS test in stroke patients. Secondary objective: to compare the records of the two inertial sensors (trunk and lumbar) to detect any significant differences in the kinematic data obtained in the SLS test. Design: cross-sectional study. While performing the SLS test, two inertial sensors were placed at lumbar (L5-S1) and trunk regions (T7–T8). Setting: Laboratory of Biomechanics (Health Science Faculty - University of Málaga). Participants: Four chronic stroke survivors (over 65 yrs old). Measurement: displacement and velocity, Rotation (X-axis), Flexion/Extension (Y-axis), Inclination (Z-axis); Resultant displacement and velocity (V): Along with SLS kinematic variables, descriptive analyses, differences between sensors locations and intra-observer and inter-observer reliability were also calculated. Differences between the sensors were significant only for left inclination velocity (p = 0.036) and extension displacement in the non-affected leg with eyes open (p = 0.038). Intra-observer reliability of the trunk sensor ranged from 0.889-0.921 for the displacement and 0.849-0.892 for velocity. Intra-observer reliability of the lumbar sensor was between 0.896-0.949 for the displacement and 0.873-0.894 for velocity. Inter-observer reliability of the trunk sensor was between 0.878-0.917 for the displacement and 0.847-0.884 for velocity. Inter-observer reliability of the lumbar sensor ranged from 0.870-0.940 for the displacement and 0.863-0.884 for velocity. There were no significant differences between the kinematic records made by an inertial sensor during the development of the SLS testing between two inertial sensors placed in the lumbar and thoracic regions. In addition, inertial sensors. Have the potential to be reliable, valid and sensitive instruments for kinematic measurements during SLS testing but further research is needed.
A randomized controlled trial of forty-five females over 18 years of age with diagnosis of thumb basal osteoarthritis in their dominant hand and with a minimum pain rating of 4/10 on the Visual Analogue Scale (VAS) during activities of daily living (ADLs) were recruited from March to June 2021. The group receiving proprioception training was compared to routine conservative physiotherapy treatment. The main purpose of this clinical trial is to test the effect of proprioception training on pain intensity in subjects with thumb osteoarthritis. Primary outcome was joint position sense (JPS) for the assessment of CMC proprioception and secondary outcomes were Visual Analogue Scale (VAS) and Canadian Occupational Performance Measure (COPM) for the assessment of patient satisfaction and the Quick-DASH which assessed upper limb function. A block randomization was carried out for the control group (n = 22) and experimental group (n = 23). Participants and evaluator were blinded to the group assignment. Proprioception training produced a statistically significant reduction in pain post intervention, but this reduction was small (d = 0.1) at the 3-month follow-up. JPS accuracy demonstrated statistically significant differences between the groups (p = 0.001) post-intervention and at the 3-month follow-up (p < 0.003). Statistically significant differences between means were found in both the Quick-Dash and COPM post intervention (both, p < 0.001), as well as at the 3-month follow-up (both, p < 0.001). There was a significant time factor for the reduction of pain intensity over time but effect sizes between groups was small at the 3-month follow-up period. Proprioceptive training improves thumb JPS accuracy; however, it does not contribute to a reduction in pain intensity in the long term. The inclusion of a proprioceptive program may be beneficial for improving individuals with thumb CMC OA sensorimotor performance. The study was registered at ClinicalTrials.gov NCT04738201. No funding was provided for this study.
Quality of life of people with severe mental illness may be decrease by the high occurrence of metabolic and cardiovascular diseases. Physical fitness emerges as a modifying factor in this population through physical activity and this modification could influence in the quality of life of this population. The aim of the present study is to determine the contribution of physical fitness to the quality of life of people with severe mental illness. In the current study, a physiotherapist and an occupational therapist assessed 62 people with severe mental illness. Physical fitness was measured with a range of 11 fitness tests that covered flexibility, strength, balance, and endurance. To assess quality of life the EQ-5D-3 L scale was used, which measures five dimensions (mobility, self-care, usual activities, pain-discomfort, and anxiety-depression). Significant correlations are presented between the quality of life and primary variables of physical fitness (balance, endurance, and upper limb strength). Endurance explained 22.9% of the variance of the quality of life in people with severe mental illness. Functional reach added another 36.2% variance to the prediction of quality of life. The results of the present study suggest that some variables of physical fitness are associated with quality of life in people with severe mental illness. The improvement in physical fitness of this population should be a primary objective. ClinicalTrials.gov Identifier: NCT02413164 “retrospective registered” Registered Febr 2017.
Introduction: Pain catastrophizing scale (PCS) is the most used scale to measure pain catastrophizing. In breast cancer survivors (BCS), pain catastrophizing is related to upper‐limbs dysfunction and disability. This study aimed to assess the internal consistency, internal structure, and convergent validity of the Spanish version of the PCS in Spanish BCS.Material and Methods: Breast cancer survivors were recruited from the service of Medical Oncology of the University Clinical Hospital Virgen de la Victoria, in Málaga (Spain). The psychometric properties were evaluated with analysis factor structure by maximum likelihood extraction (MLE), internal consistency, and construct validity by confirmatory factor analysis (CFA).Results: Factor structure was three‐dimensional, and one item was removed due to cross‐loading. The new 12‐item PCS showed a high internal consistency for the total score (α = 0.91) and a good homogeneity, and CFA revealed a satisfactory fit. PCS showed an acceptable correlation with FACS (r = 0.53, p < 0.01).Conclusion: Pain catastrophizing scale is a valid and reliable instrument to evaluate pain catastrophizing in Spanish BCS. This tool may help clinicians in the management of pain by assessing pain and by measuring the effect of interventions.
Stroke is a very common pathology, with a high prevalence of impairment of the sensorimotor function of the upper limb. There are many scales that assess this variable. Fugl-Meyer Assessment is one of the most widely used, but there are many versions of this scale to assess this construct. To identify, critically appraise, and summarize the different Fugl-Meyer Assessment (FMA) versions to recognize which is better to measure upper-extremity sensorimotor function in stroke patients. A psychometric systematic review was carried out in this research. An exhaustive search was conducted during June and July 2023 in the following databases: Pubmed, Web of Science (WoS), Open Grey, Scielo, Cochrane, Dialnet, and LILACS. By the most updated consensus-based standards fot the selection of health status Measurement INstruments methodology (COSMIN) and preferred reporting items for systematic reviews and meta-analyses (PRISMA) statements for a systematic review of the measurement properties of existing patient-reported outcome measures to select the most appropriate outcome measurement instrument. The protocol of this systematic review was registered in Open Science Framework (https://osf.io/dy54p/). About 22 versions of the FMA were identified in 36 studies. The Upper Extremity subscale of the Fugl-Meyer Assessment (FMA-UE) was the version most frequently analyzed (n = 13) among the included articles. Fugl-Meyer Assessment (Full version, 50 items, FMA) was the questionnaire version with the most evaluated psychometric characteristics and most translations, with the better score regarding the quality of evidence, which indicates that is the recommended FMA version to assess upper-extremity sensorimotor function in stroke patients.