The particular structure of the sublimation front in vacuum freeze-drying of porous media is, in most situations, not accessible at the pore scale. The classical measurement techniques access the process only globally. Knowledge about the structure of the front, however, is necessary for prescriptive analysis of freeze-drying, as it dictates not only drying velocity, drying time, and overall energy consumption, but also the material properties after drying. This is especially relevant in situations in which the freeze-drying process is carried out close to the collapse temperature of the product. We, therefore, study the sublimation of ice with neutron tomography and analyze the spatial formation of the dry space using the example of frozen cylindrical maltodextrin with drying parameters at the limit of material collapse. We show that the sublimation front forms unique fractal structures that differ strongly from the usual form of a flat front. Distinct dry fingers covering the sample, in addition to a fractal peripheral sublimation front, were observed. The findings are important for the understanding of freeze-drying processes and will serve as a basis for the development of microscale models of freeze-drying.
1 January 2020 in Review of Scientific Instruments
This article shows a new conceptional design of an experimental setup for in situ visualization of the lyophilization process using neutron radiography and computed tomography and its validation. The setup is designed for the neutron imaging beam line ANTARES at FRM II, considering all the requirements for this method. Neutrons are ideally suited to detect water in a sample because of the high neutron attenuation of hydrogen, whereas other materials like aluminum have a low absorption of neutrons resulting in an image where the drying fronts in bulk materials are observable. Consisting of a freeze-drying cell and a sample-stick, the setup is basically inspired by a common freeze-drying unit. The cell is axial symmetrical to allow computed tomography measurements. The developed sample stick connects the vacuum cell with the measurement devices and the vacuum pump. Experiments were performed at FRM II, showing that the setup is functional. In addition, the experiments discovered some possibilities for improvements, which can be used in further measurements.
This paper shows the development of a freeze-drying stage for in-situ μ-CT measurements. The stage can operate in a temperature range of −40 °C up to 70 °C, and a pressure range from atmospheric pressure to 7 Pa at the sample holder. To get the best visualization of the probe, it is fundamental that the materials around the sample holder are not absorbing most of the radiation. For this reason, we built an axial symmetrical stage built out of polyetheretherketon (PEEK). A test of the stage by different freeze-drying experiments with maltodextrin and sucrose particles and solutions demonstrated its suitability to visualize the freeze-drying processes in-situ. It was possible to track the drying front during the process by radiographic and tomographic measurements, as well as to visually resolve the ice crystals and porous structure in tomographic measurements. Using different samples and process parameters, we showed that the freeze-drying stage is not only suitable for in-situ µ-CT measurements, but also allows us to use the stage for other imaging methods such as neutron imaging, and for any sample where a controlled environment is needed.
The gentle yet cost-effective drying of sensitive products in the food and pharmaceutical industries is becoming increasingly important. To maintain sensitive ingredients, color, structure, and viability of micro-organisms, often freeze-drying is the only possible way to preserve the product. As many products come in as bulk material, they are dried on heated shelves resulting in poor heat and mass transport through the bed. Resulting in a very time and cost intensive process. Therefore, efforts are being made to improve the mass and heat transport of the process. The outer mass transport through the bulk can be improved by continuous mixing of the pellets, facilitating the removal of water vapor from the condenser. In addition, the issue of limited heat transport can be addressed by using volumetric energy input from microwaves. This process is called dynamic microwave freeze-drying. As dynamic microwave freeze-drying is a combined drying and mixing process, with particle properties continuously changing during drying, it is necessary to gain a more detailed insight into the process. For this purpose, a drier is designed that is capable of in situ neutron imaging, a method sensitive to a material’s hydrogen content. This paper presents the design of a pilot-scale microwave freeze dryer for in situ neutron imaging and shows the first images taken during the dynamic microwave freeze-drying of bulk particles at the Center for Energy Research, Budapest Neutron Center in Budapest, Hungary.