In this paper, the effect of the inclination angle on the thermal performance of a two-phase closed thermosyphon with different filling ratios has been investigated experimentally under normal operating conditions. A series of experiments were carried out for inclination angle range of 5°–90° and filling ratios of 15%, 22%, and 30%. A copper thermosyphon with an outside diameter of 16 mm, an inside diameter of 14.5 mm, and a length of 1000 mm was employed. Distilled water was used as the working fluid. The results show that the two-phase closed thermosyphon has the highest thermal performance in the inclination angle range of 15°–60°. A good agreement was observed between the experimental results of this study and those available in the open literature. The interesting phenomenon of geyser boiling occurred in our experiments for filling ratios equal or greater than 30%. The geyser boiling puts no limitation on thermal performance of thermosyphon, but it should be avoided because it damages the condenser end cap due to the slug striking.
In this paper, geyser boiling phenomenon (GBP) in a two-phase closed thermosyphon has been investigated experimentally. Here, the effects of the inclination angle, filling ratio, input heat rate, mass flowrate of coolant, and inside diameter of the tube on the GBP have been discussed. Three copper thermosyphons with inside diameters of 14 mm, 20 mm, and 24 mm and a length of 1000 mm were employed. Distilled water was used as the working fluid. A series of experiments was carried out to investigate the effect of the inclination angle range of 5° to 90°, the input heat rate range of 50 to 312.4 W, the coolant mass flow rate range of 0.00389 to 0.0164 kg/s, and the filling ratio range of 15 to 45%. The GBP has been investigated by analyzing the time variations of the evaporator and adiabatic wall temperature and outlet water temperature from condenser jacket. The results show that the period of GBP was longer for higher inclination angles and filling ratios. Furthermore, it was discovered that the GBP did not take place for inclination angles of less than 15°.
19 January 2019 in Journal of Thermal Analysis and Calorimetry