Qianying Yi

Dr. Qianying Yi

Leibniz Institute for Agricultural Engineering and Bioeconomy
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2018 in Energy and Buildings
Verified
Journal Article
Closed access
Qianying YiQianying Yi
Qianying Yi
GZGuoqiang Zhang
Guoqiang Zhang
MKMarcel König
Marcel König
David JankeDavid Janke
David Janke
Sabrina HempelSabrina Hempel
Sabrina Hempel
Thomas AmonThomas Amon
Thomas Amon

1 July 2019 in Computers and Electronics in Agriculture
Verified
Journal Article
Closed access
Qianying YiQianying Yi
Qianying Yi
Xiaoshuai WangXiaoshuai Wang
Xiaoshuai Wang
GZGuoqiang Zhang
Guoqiang Zhang
HLHao Li
Hao Li
David JankeDavid Janke
David Janke
Thomas AmonThomas Amon
Thomas Amon

1 September 2018 in Energy and Buildings
Verified
Journal Article
Closed access
Qianying YiQianying Yi
Qianying Yi
MKMarcel König
Marcel König
David JankeDavid Janke
David Janke
Sabrina HempelSabrina Hempel
Sabrina Hempel
GZGuoqiang Zhang
Guoqiang Zhang
Thomas AmonThomas Amon
Thomas Amon

31 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
David JankeDavid Janke
David Janke
Qianying YiQianying Yi
Qianying Yi
LTLars Thormann
Lars Thormann
Sabrina HempelSabrina Hempel
Sabrina Hempel
BABarbara Amon
Barbara Amon
Thomas AmonThomas Amon
Thomas Amon
The direct measurement of emissions from naturally ventilated dairy barns is challenging due to their large openings and the turbulent and unsteady airflow at the inlets and outlets. The aim of this study was to quantify the impacts of the number and positions of sensors on the estimation of volume flow rate and emissions. High resolution measurements of a naturally ventilated scaled building model in an atmospheric boundary layer wind tunnel were done. Tracer gas was released inside the model and measured at the outlet area, using a fast flame ionization detector (FFID). Additionally, the normal velocity on the area was measured using laser Doppler anemometry (LDA). In total, for a matrix of 65 × 4 sensor positions, the mean normal velocities and the mean concentrations were measured and used to calculate the volume flow rate and the emissions. This dataset was used as a reference to assess the accuracy while systematically reducing the number of sensors and varying the positions of them. The results showed systematic errors in the emission estimation up to +97%, when measurements of concentration and velocity were done at one constant height. This error could be lowered under 5%, when the concentrations were measured as a vertical composite sample.

1 September 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Chayan SahaChayan Saha
Chayan Saha
Qianying YiQianying Yi
Qianying Yi
David JankeDavid Janke
David Janke
Sabrina HempelSabrina Hempel
Sabrina Hempel
BABarbara Amon
Barbara Amon
Thomas AmonThomas Amon
Thomas Amon
Airflow inside naturally ventilated dairy (NVD) buildings is highly variable and difficult to understand due to the lack of precious measuring techniques with the existing methods. Computational fluid dynamics (CFD) was applied to investigate the effect of different seasonal opening combinations of an NVD building on airflow patterns and airflow rate inside the NVD building as an alternative to full scale and scale model experiments. ANSYS 2019R2 was used for creating model geometry, meshing, and simulation. Eight ventilation opening combinations and 10 different reference air velocities were used for the series of simulation. The data measured in a large boundary layer wind tunnel using a 1:100 scale model of the NVD building was used for CFD model validation. The results show that CFD using standard k-ε turbulence model was capable of simulating airflow in and outside of the NVD building. Airflow patterns were different for different opening scenarios at the same external wind speed, which may affect cow comfort and gaseous emissions. Guiding inlet air by controlling openings may ensure animal comfort and minimize emissions. Non-isothermal and transient simulations of NVD buildings should be carried out for better understanding of airflow patterns.

1 October 2020 in Computers and Electronics in Agriculture
Verified
Journal Article
Closed access
CQChao Qin
Chao Qin
XWXiaoshuai Wang
Xiaoshuai Wang
GZGuoqiang Zhang
Guoqiang Zhang
Qianying YiQianying Yi
Qianying Yi
YHYong He
Yong He
KWKaiying Wang
Kaiying Wang