Prabhakar Bandaru

Prabhakar Bandaru


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2005 in Nature Materials
Verified
Journal Article
Closed access
PDF file
PBPrabhakar Bandaru
Prabhakar Bandaru
CDC. Daraio
C. Daraio
SJS. Jin
S. Jin
ARA. M. Rao
A. M. Rao

10 August 2015 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
AKAlireza Kargar
Alireza Kargar
SYSerdar Yavuz
Serdar Yavuz
TKTae Kyoung Kim
Tae Kyoung Kim
CLChin-Hung Liu
Chin-Hung Liu
CKCihan Kuru
Cihan Kuru
PBPrabhakar Bandaru
Prabhakar Bandaru

4 April 2016 in Nanotechnology
Verified
Journal Article
Closed access
PDF file
CKCihan Kuru
Cihan Kuru
DCDuyoung Choi
Duyoung Choi
AKAlireza Kargar
Alireza Kargar
CLChin Hung Liu
Chin Hung Liu
SYSerdar Yavuz
Serdar Yavuz
PBPrabhakar Bandaru
Prabhakar Bandaru
We report a flexible hydrogen sensor, composed of WS 2 nanosheet–Pd nanoparticle composite film, fabricated on a flexible polyimide substrate. The sensor offers the advantages of light-weight, mechanical durability, room temperature operation, and high sensitivity. The WS 2 –Pd composite film exhibits sensitivity ( R 1 / R 2, the ratio of the initial resistance to final resistance of the sensor) of 7.8 to 50 000 ppm hydrogen. Moreover, the WS 2 –Pd composite film distinctly outperforms the graphene–Pd composite, whose sensitivity is only 1.14. Furthermore, the ease of fabrication holds great potential for scalable and low-cost manufacturing of hydrogen sensors.

3 October 2018 in Nature Communications
Verified
Journal Article
Open access
PDF file
BFB. Fan
B. Fan
ABA. Bhattacharya
A. Bhattacharya
PBPrabhakar Bandaru
Prabhakar Bandaru
The generation of electrical voltage through the flow of an electrolyte over a charged surface may be used for energy transduction. Here, we show that enhanced electrical potential differences (i.e., streaming potential) may be obtained through the flow of salt water on liquid-filled surfaces that are infiltrated with a lower dielectric constant liquid, such as oil, to harness electrolyte slip and associated surface charge. A record-high figure of merit, in terms of the voltage generated per unit applied pressure, of 0.043 mV Pa−1 is obtained through the use of the liquid-filled surfaces. In comparison with air-filled surfaces, the figure of merit associated with the liquid-filled surface increases by a factor of 1.4. These results lay the basis for innovative surface charge engineering methodology for the study of electrokinetic phenomena at the microscale, with possible application in new electrical power sources.

26 February 2016 in Nanoscale
Verified
Journal Article
Closed access
PDF file
SYS. Yavuz
S. Yavuz
CKC. Kuru
C. Kuru
DCD. Choi
D. Choi
AKA. Kargar
A. Kargar
SJS. Jin
S. Jin
PBPrabhakar Bandaru
Prabhakar Bandaru
It is shown that coating graphene–silicon (Gr/Si) Schottky junction based solar cells with graphene oxide (GO) improves the power conversion efficiency (PCE) of the cells, while demonstrating unprecedented device stability. The PCE has been shown to be increased to 10.6% (at incident radiation of 100 mW cm−2) for the Gr/Si solar cell with an optimal GO coating thickness compared to 3.6% for a bare/uncoated Gr/Si solar cell. The p-doping of graphene by the GO, which also serves as an antireflection coating (ARC) has been shown to be a main contributing factor to the enhanced PCE. A simple spin coating process has been used to apply GO with thickness commensurate with an anti-refection coating (ARC) and indicates the suitability of the developed methodology for large-scale solar cell assembly.

28 June 2022 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
DBDeependra Kumar Ban
Deependra Kumar Ban
TBTyler Bodily
Tyler Bodily
AKAbhijith G. Karkisaval
Abhijith G. Karkisaval
YDYongliang Dong
Yongliang Dong
SNShreyam Natani
Shreyam Natani
RLRatnesh Lal
Ratnesh Lal
We have developed a DNA aptamer-conjugated graphene field-effect transistor (GFET) biosensor platform to detect receptor-binding domain (RBD), nucleocapsid (N), and spike (S) proteins, as well as viral particles of original Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) coronavirus and its variants in saliva samples. The GFET biosensor is a label-free, rapid (≤20 min), ultrasensitive handheld wireless readout device. The limit of detection (LoD) and the limit of quantitation (LoQ) of the sensor are 1.28 and 3.89 plaque-forming units (PFU)/mL for S protein and 1.45 and 4.39 PFU/mL for N protein, respectively. Cognate spike proteins of major variants of concern (N501Y, D614G, Y453F, Omicron-B1.1.529) showed sensor response ≥40 mV from the control (aptamer alone) for fM to nM concentration range. The sensor response was significantly lower for viral particles and cognate proteins of Middle East Respiratory Syndrome (MERS) compared to SARS-CoV-2, indicating the specificity of the diagnostic platform for SARS-CoV-2 vs. MERS viral proteins. During the early phase of the pandemic, the GFET sensor response agreed with RT-PCR data for oral human samples, as determined by the negative percent agreement (NPA) and positive percent agreement (PPA). During the recent Delta/Omicron wave, the GFET sensor also reliably distinguished positive and negative clinical saliva samples. Although the sensitivity is lower during the later pandemic phase, the GFET-defined positivity rate is in statistically close alignment with the epidemiological population-scale data. Thus, the aptamer-based GFET biosensor has a high level of precision in clinically and epidemiologically significant SARS-CoV-2 variant detection. This universal pathogen-sensing platform is amenable for a broad range of public health applications and real-time environmental monitoring.