Reza Hashemi

Dr. Reza Hashemi

College of Science and Engineering, Medical Device Research Institute, Flinders University, Adelaide, Australia
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2015 in BioMed Research International
Verified
Journal Article
Open access
PDF file
SHS. Hussenbocus
S. Hussenbocus
DKD. Kosuge
D. Kosuge
Lucian Bogdan SolomonLucian Bogdan Solomon
Lucian Bogdan Solomon
DHD. W. Howie
D. W. Howie
Reza HashemiReza Hashemi
Reza Hashemi
Modularity at the head-neck junction of the femoral component in THA became popular as a design feature with advantages of decreasing implant inventory and allowing adjustment of leg length, offset, and soft tissue balancing through different head options. The introduction of a new modular interface to femoral stems that were previously monoblock, or nonmodular, comes with the potential for corrosion at the taper junction through mechanically assisted crevice corrosion. The incidence of revision hip arthroplasty is on the rise and along with improved wear properties of polyethylene and ceramic, use of larger femoral head sizes is becoming increasingly popular. Taper corrosion appears to be related to all of its geometric parameters, material combinations, and femoral head size. This review article discusses the pathogenesis, risk factors, clinical assessment, and management of taper corrosion at the head-neck junction.

1 July 2008 in Engineering Failure Analysis
Verified
Journal Article
Closed access
TCT.N. Chakherlou
T.N. Chakherlou
Reza HashemiReza Hashemi
Reza Hashemi
JVJ. Vogwell
J. Vogwell

5 August 2019 in Lubricants
Verified
Journal Article
Open access
PDF file
SKSukhpreet Kaur
Sukhpreet Kaur
KGKhashayar Ghadirinejad
Khashayar Ghadirinejad
Reza HashemiReza Hashemi
Reza Hashemi
The need for metallic biomaterials will always remain high with their growing demand in joint replacement in the aging population. This creates need for the market and researchers to focus on the development and advancement of the biometals. Desirable characteristics such as excellent biocompatibility, high strength, comparable elastic modulus with bones, good corrosion resistance, and high wear resistance are the significant issues to address for medical implants, particularly load-bearing orthopedic implants. The widespread use of titanium alloys in biomedical implants create a big demand to identify and assess the behavior and performance of these alloys when used in the human body. Being the most commonly used metal alloy in the fabrication of medical implants, mainly because of its good biocompatibility and corrosion resistance together with its high strength to weight ratio, the tribological behavior of these alloys have always been an important subject for study. Titanium alloys with improved wear resistance will of course enhance the longevity of implants in the body. In this paper, tribological performance of titanium alloys (medical grades) is reviewed. Various methods of surface modifications employed for titanium alloys are also discussed in the context of wear behavior.

1 April 2021 in Journal of Manufacturing Processes
Verified
Journal Article
Closed access
ABAlireza Dareh Baghi
Alireza Dareh Baghi
Shahrooz NafisiShahrooz Nafisi
Shahrooz Nafisi
Reza HashemiReza Hashemi
Reza Hashemi
HEHeike Ebendorff-Heidepriem
Heike Ebendorff-Heidepriem
Reza GhomashchiReza Ghomashchi
Reza Ghomashchi

1 May 2015 in Universal Journal of Biomedical Engineering
Verified
Journal Article
Open access
PDF file
SKSushmitha Kuppusami
Sushmitha Kuppusami
Reza HashemiReza Hashemi
Reza Hashemi
This paper reviews various aspects of parylene coatings in medical devices and industry and summarises the fabrication methods of parylene coatings and their potential medical applications. In medical industry, two major beneficial properties of parylene include excellent barrier qualities and inherent bio-compatibility and bio-stability. The need for a bio-compatible material with good surface characteristics is of paramount importance. The recent findings indicate the application of parylene coatings in several areas of medical industry such as surgical instruments, implants, medical devices, mandrels, and medical electronics. Parylene has been slowly introduced into the research market, and has found to be competitive for available materials in the market. A review of the literature was undertaken to identify the prospective use to determine whether parylene coatings can survive the needs in medical industry.

9 August 2019 in Metals
Verified
Journal Article
Open access
PDF file
PAPooria Afzali
Pooria Afzali
Reza GhomashchiReza Ghomashchi
Reza Ghomashchi
Reza HashemiReza Hashemi
Reza Hashemi
The corrosion behaviour of new generation titanium alloys (β-type with low modulus) for medical implant applications is of paramount importance due to their possible detrimental effects in the human body such as release of toxic metal ions and corrosion products. In spite of remarkable advances in improving the mechanical properties and reducing the elastic modulus, limited studies have been done on the electrochemical corrosion behaviour of various types of low modulus titanium alloys including the effect of different beta-stabilizer alloying elements. This development should aim for a good balance between mechanical properties, design features, metallurgical aspects and, importantly, corrosion resistance. In this article, we review several significant factors that can influence the corrosion resistance of new-generation titanium alloys such as fabrication process, body electrolyte properties, mechanical treatments, alloying composition, surface passive layer, and constituent phases. The essential factors and their critical features are discussed. The impact of various amounts of α and β phases in the microstructure, their interactions, and their dissolution rates on the surface passive layer and bulk corrosion behaviour are reviewed and discussed in detail. In addition, the importance of different corrosion types for various medical implant applications is addressed in order to specify the significance of every corrosion phenomenon in medical implants.