The complex environment within a crop canopy leads to a high variability of the air temperature within the canopy, and, therefore, air temperature measured at a weather station (WS) does not represent the internal energy within a crop. The objectives of this study were to quantify the difference between the air temperature measured at a standard WS and the air temperature within a six-year-old vineyard (cv. Chardonnay) and to determine the degree of uncertainty associated with the assumption that there is no difference between the two temperatures when air temperature is used as input in grapevine models. Thermistors and thermocouples were installed within the vine canopy at heights of 0.5 m and 1.2 m above the soil surface and immediately adjacent to the berry clusters. In the middle of the clusters sensors were installed to determine the temperature of the air surrounding the clusters facing east and west. The data were recorded within the canopy from December 2015 to June 2017 as well as at the standard WS that was installed close to the vineyard (410 m). Significant differences were found between the air temperatures measured at the WS and those within the vineyard during the summer when the average daily minimum air temperature within the canopy was 1.2°C less than at the WS and the average daily maximum air temperature in the canopy was 2.0°C higher than at the WS. The mean maximum air temperature measured in the clusters facing east was 1.5°C higher and west 4.0°C higher than the temperature measured at the WS. Therefore, models that assume that air temperature measured at a weather station is similar to air temperature measured in the vineyard canopy could have greater uncertainty than models that consider the temperature within the canopy.
27 November 2018 in Theoretical and Applied Climatology
In the Colombian Sugarcane Research Center CENICAÑA, efficient use of water is always performed based on estimating reference evapotranspiration. In this method, class A pans have been used to estimate the reference evapotranspiration, which provides a more precise estimate of this important variable for water resource management. The objective of this study was to evaluate different reference evapotranspiration methods for the region of influence of the climatological station of the CENICAÑA experimental station. The class A pan method traditionally used in CENICAÑA was compared with and the Penman-Monteith FAO 56 standard method. The historical series used was from January 1, 1994, to December 31, 2014. The climatic variables were the maximum, mean, and minimum temperatures, the mean relative air humidity, solar radiation, and wind speed at 10 m. Willmott’s coefficients, the confidence index (c), and the root mean squared error were used in the performance evaluation. In the comparison with the Penman-Monteith FAO 56 method, all methods presented performance below the minimum requirement of (c) = 0.400. When all methods were compared with the method used in CENICAÑA (Class A pan), only the Penman-Monteith FAO 56 method showed performance classified as good (c = 0.689).
28 September 2020 in Environment, Development and Sustainability