Andy Alcantar

Mr. Andy Alcantar


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2021 in Journal of Engineering for Gas Turbines and Power
Verified
Journal Article
Closed access
PDF file
Luis San AndrésLuis San Andrés
Luis San Andrés
JTJonathan Toner
Jonathan Toner
AAAndy Alcantar
Andy Alcantar
Operation of tilting pad journal bearings (TPJBs) with a reduced flow decreases pumping costs and oil sump storage. A low supplied oil flow improves system energy efficiency by reducing drag power losses, albeit the temperature rise in both the bearing pads and the lubricating oil become a concern. This paper presents measurements of the static and dynamic load performance of a flooded ends TPJB lubricated with an ISO VG 46 oil supplied at 60 °C, and with a flow rate ranging from 150% to just ∼5% of a nominal supply condition. The flow range covers both over-flooded and starved flow conditions. The test bearing is a four-pad, 102 mm diameter, center pivot, with single orifice feeds, and configured with end seals to flood the bearing housing. The experiments include operation at two shaft speeds = 6 krpm and 12 krpm (= 64 m/s surface speed) and under three specific loads = 0.345 MPa, 1.03 MPa, and 2.07 MPa applied in between pads (LBP). The measurements show the bearing drag power loss decreases by nearly 20% when the flow rate drops to 50% of nominal. However, halving the flow produces a raise in pad subsurface temperatures, ∼7 °C for operation at 12 krpm. Flow reduction below 50% does result in even more substantial power savings; however, it also produces too hot pad temperatures that approach 130 °C, a known limit for Babbitt material safe operation. The bearing static eccentricity (e) and direct stiffnesses Kxx < Kyy (load direction) do not show a significant dependency on the supplied flow, either above or below the nominal condition. A minor stiffness hardening does occur for very low flow conditions, 5% or so of nominal. Damping coefficients (Cxx ∼ Cyy) decrease by ∼30% as the flow rate decreases from 150% to just a few % of the nominal flow. The experimental results are first to quantify the operation of a TPJB supplied with minute amounts of lubricant flow. A test with a very low flow rate at ∼2% of nominal and under a light load produced the emergence of a broadband subsynchronous vibration (SSV) frequency, albeit with a very small amplitude.