Weichao Zhang

Dr. Weichao Zhang

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 July 2013 in The Journal of Physical Chemistry A
Verified
Journal Article
Closed access
BDBenni Du
Benni Du
WZWeichao Zhang
Weichao Zhang

1 November 2021 in Talanta
Verified
Journal Article
Open access
WZWeichao Zhang
Weichao Zhang
JLJianfeng Lin
Jianfeng Lin
SFSui Fang
Sui Fang
CLChen Li
Chen Li
XYXiaowei Yi
Xiaowei Yi
Jiang XuJiang Xu
Jiang Xu
Although triple-quadrupole inductively coupled plasma-mass spectrometry (ICP-MS/MS) has become an attractive technique for the measurement of long-lived radionuclides, the abundance sensitivity, isobaric and polyatomic ions interferences seriously restrict the application. The spectral peak tailing and uranium hydrides (UH+, UH2+) from 238U have a serious influence on the accurate measurement of 239Pu and 240Pu, especially for the ultra-trace level plutonium isotopes in the higher uranium sample. A new method was developed using ICP-MS/MS measurement in mass-shift mode with collision-reaction gas combined with a chemical separation procedure. As O2 readily converted Pu+ ion to PuO2+, while disassociated the interfering diatomic ions of interfering elements (U, Pb, Hg, Tl, etc.), the interferences from these elements were completely eliminated if plutonium was detected as PuO2+ at the m/z more than 270. By the mass filter in MS/MS mode combined with O2 as reaction gas the lower peak tailing of 238U+ (<5 × 10-12) was significantly suppressed. By this way, the 238UO2H+/238UO2+ atomic ratio was reduced to 4.82 × 10-9, which is significantly lower than that of other collision-reaction gas modes. Interferences from Pb, Hg and Tl polyatomic ions were also completely eliminated. Thus, accurate measurement of ultra-trace level 239Pu in high uranium sample solutions with the 239Pu/238U concentration ratio of 10-10 was achieved by the mass-shift mode with 0.15 mL/min O2/He + 12.0 mL/min He as collision-reaction gas, and high elimination efficiency of uranium interferences up to 1014 can be obtained by combination with the chemical separation using a single UTEVA resin column. The developed method can be applied to accurately determine the fg level 239Pu in high uranium samples, such as large-size deep seawater, deep soil and sediment, uranium debris of nuclear fuel.

1 November 2021 in Environmental Pollution
Verified
Journal Article
Open access
WZWeichao Zhang
Weichao Zhang
XHXiaolin Hou
Xiaolin Hou
HZHaitao Zhang
Haitao Zhang
YWYanyun Wang
Yanyun Wang
HDHaijun Dang
Haijun Dang
NCNing Chen
Ning Chen
Concentrations of 239Pu and 240Pu in 163 surface soil samples and five soil cores collected from the northeast and north China were analyzed using the radiochemical separation combined with inductively coupled plasma mass spectrometry measurement. The average 240Pu/239Pu atomic ratios (0.185 ± 0.018) for all surface soil samples indicated that the global fallout is the major source of plutonium in the studied region. The 239,240Pu concentrations of the surface soil ranged from 0.002 mBq/g to 4.82 mBq/g, lying in the range of the reported results in the areas with similar latitude, except for a few samples. The distribution of 239,240Pu in this region is controlled by the deposition of plutonium in the atmosphere and its preservation in the soil, which were affects by multi-factors such as topography, climate, utilization of the land and vegetation coverage. The analytical results could be used as the baseline data for the assessment of the impact of nuclear activities in the past and the future.

14 April 2022 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
WZWeichao Zhang
Weichao Zhang
JLJianfeng Lin
Jianfeng Lin
HZHaitao Zhang
Haitao Zhang
SFSui Fang
Sui Fang
CLChen Li
Chen Li
JXJiang Xu
Jiang Xu
ICP-MS/MS measurement with mass-shift mode using O2/He–He collision gas can effectively suppress the interference of polyatomic ions from interfering elements (Pb, Hg, Tl,etc.) in analysis of ultra-trace level241Am in environmental samples.

1 February 2006 in Journal of Molecular Structure: THEOCHEM
Verified
Journal Article
Closed access
WZWeichao Zhang
Weichao Zhang
BDBenni Du
Benni Du

16 April 2015 in The Journal of Physical Chemistry A
Verified
Journal Article
Closed access
WZWeichao Zhang
Weichao Zhang
BDBenni Du
Benni Du