Crescenzio Minervini

Dr. Crescenzio Minervini

Hematology section, Department of Emergency and Organ Transplantations, University of Bari “Aldo Moro”, 70124 Bari, Italy
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2006 in Human Molecular Genetics
Verified
Journal Article
Open access
PDF file
CSClelia Tiziana Storlazzi
Clelia Tiziana Storlazzi
TFThoas Fioretos
Thoas Fioretos
CSCecilia Surace
Cecilia Surace
ALAngelo Lonoce
Angelo Lonoce
AMAngela Mastrorilli
Angela Mastrorilli
MRMariano Rocchi
Mariano Rocchi
Double minutes (dmin)—circular, extra-chromosomal amplifications of specific acentric DNA fragments—are relatively frequent in malignant disorders, particularly in solid tumors. In acute myeloid leukemia (AML) and myelodysplastic syndromes (MDS), dmin are observed in ∼1% of the cases. Most of them consist of an amplified segment from chromosome band 8q24, always including the MYC gene. Besides this information, little is known about their internal structure. We have characterized in detail the genomic organization of 32 AML and two MDS cases with MYC-containing dmin. The minimally amplified region was shown to be 4.26 Mb in size, harboring five known genes, with the proximal and the distal amplicon breakpoints clustering in two regions of ∼500 and 600 kb, respectively. Interestingly, in 23 (68%) of the studied cases, the amplified region was deleted in one of the chromosome 8 homologs at 8q24, suggesting excision of a DNA segment from the original chromosomal location according to the ‘episome model’. In one case, sequencing of both the dmin and del(8q) junctions was achieved and provided definitive evidence in favor of the episome model for the formation of dmin. Expression status of the TRIB1 and MYC genes, encompassed by the minimally amplified region, was assessed by northern blot analysis. The TRIB1 gene was found over-expressed in only a subset of the AML/MDS cases, whereas MYC, contrary to expectations, was always silent. The present study, therefore, strongly suggests that MYC is not the target gene of the 8q24 amplifications.

10 October 2016 in Diagnostic Pathology
Verified
Journal Article
Open access
PDF file
Crescenzio MinerviniCrescenzio Minervini
Crescenzio Minervini
Cosimo CumboCosimo Cumbo
Cosimo Cumbo
POPaola Orsini
Paola Orsini
CBClaudia Brunetti
Claudia Brunetti
Luisa AnelliLuisa Anelli
Luisa Anelli
Francesco AlbanoFrancesco Albano
Francesco Albano
The assessment of TP53 mutational status is becoming a routine clinical practice for chronic lymphocytic leukemia patients (CLL). A broad spectrum of molecular techniques has been employed so far, including both direct Sanger sequencing and next generation sequencing. Oxford Nanopore Technologies recently released the MinION an USB-interfaced sequencer. In this paper we report our experience, with the MinION technology for the detection of the TP53 gene mutation in CLL patients. Twelve CLL patients at diagnosis were included in this study. All except one patient showed the TP53 gene deletion in Fluorescence in situ hybridization experiments. Patients were investigated for TP53 mutation by Sanger and by MinION sequencing. Analysis by Sanger was performed according with the IARC protocol. Analysis by MinION was performed adopting a strategy based on long template PCR, read error correction, and post variant calling filtering. Due to the high error rate of nanopore technology, sequence data were both used directly and before correction with two different in silico methods: ALEC and nanocorrect. A mean error rate of 15 % was detected before correction that was reduced to 4-5 % after correction. Analysis by Sanger sequencing was able to detect four patients mutated for TP53. MinION analysis detected one more mutated patient previously not detected from Sanger. In our hands, the Nanopore technology shows correlation with Sanger sequencing but more sensitive, manageable and less expensive, and therefore has proven to be a useful tool for TP53 gene mutation detection.

1 July 2018 in The Journal of Molecular Diagnostics
Verified
Journal Article
Closed access
NCNicoletta Coccaro
Nicoletta Coccaro
LALuisa Anelli
Luisa Anelli
AZAntonella Zagaria
Antonella Zagaria
PCPaola Casieri
Paola Casieri
GTGiuseppina Tota
Giuseppina Tota
Francesco AlbanoFrancesco Albano
Francesco Albano

7 August 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
POPaola Orsini
Paola Orsini
Crescenzio MinerviniCrescenzio Minervini
Crescenzio Minervini
Cosimo CumboCosimo Cumbo
Cosimo Cumbo
LALuisa Anelli
Luisa Anelli
AZAntonella Zagaria
Antonella Zagaria
Francesco AlbanoFrancesco Albano
Francesco Albano
We report a customized gene panel assay based on multiplex long-PCR followed by third generation sequencing on nanopore technology (MinION), designed to analyze five frequently mutated genes in chronic lymphocytic leukemia (CLL): TP53, NOTCH1, BIRC3, SF3B1 and MYD88. For this purpose, 12 patients were selected according to specific cytogenetic and molecular features significantly associated with their mutational status. In addition, simultaneous analysis of the targets genes was performed by molecular assays or Sanger Sequencing. Data analysis included mapping to the GRCh37 human reference genome, variant calling and annotation, and average sequencing depth/error rate analysis. The sequencing depth resulted on average higher for smaller amplicons, and the final breadth of coverage of the panel was 94.1%. The error rate was about 6% and 2% for insertions/deletions and single nucleotide variants, respectively. Our gene panel allows analysis of the prognostically relevant genes in CLL, with two PCRs per patient. This strategy offers an easy and affordable workflow, although further advances are required to improve the accuracy of the technology and its use in the clinical field. Nevertheless, the rapid and constant development of nanopore technology, in terms of chemistry advances, more accurate basecallers and analysis software, offers promise for a wide use of MinION in the future.

9 December 2019 in Genes
Verified
Journal Article
Open access
PDF file
Cosimo CumboCosimo Cumbo
Cosimo Cumbo
Crescenzio MinerviniCrescenzio Minervini
Crescenzio Minervini
POPaola Orsini
Paola Orsini
Luisa AnelliLuisa Anelli
Luisa Anelli
AZAntonella Zagaria
Antonella Zagaria
Francesco AlbanoFrancesco Albano
Francesco Albano
Acute myeloid leukemia (AML) clinical settings cannot do without molecular testing to confirm or rule out predictive biomarkers for prognostic stratification, in order to initiate or withhold targeted therapy. Next generation sequencing offers the advantage of the simultaneous investigation of numerous genes, but these methods remain expensive and time consuming. In this context, we present a nanopore-based assay for rapid (24 h) sequencing of six genes (NPM1, FLT3, CEBPA, TP53, IDH1 and IDH2) that are recurrently mutated in AML. The study included 22 AML patients at diagnosis; all data were compared with the results of S5 sequencing, and discordant variants were validated by Sanger sequencing. Nanopore approach showed substantial advantages in terms of speed and low cost. Furthermore, the ability to generate long reads allows a more accurate detection of longer FLT3 internal tandem duplications and phasing double CEBPA mutations. In conclusion, we propose a cheap, rapid workflow that can potentially enable all basic molecular biology laboratories to perform detailed targeted gene sequencing analysis in AML patients, in order to define their prognosis and the appropriate treatment.

1 May 2017 in The Journal of Molecular Diagnostics
Verified
Journal Article
Closed access
CBClaudia Brunetti
Claudia Brunetti
LALuisa Anelli
Luisa Anelli
AZAntonella Zagaria
Antonella Zagaria
AMAngela Minervini
Angela Minervini
Crescenzio MinerviniCrescenzio Minervini
Crescenzio Minervini
Francesco AlbanoFrancesco Albano
Francesco Albano