Binguang Jia

Dr. Binguang Jia


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019 in Solar Energy
Verified
Journal Article
Closed access
BJBinguang Jia
Binguang Jia
FLFang Liu
Fang Liu
DWDa Wang
Da Wang

1 January 2020 in Applied Thermal Engineering
Verified
Journal Article
Closed access
DWDa Wang
Da Wang
YLYanhua Lai
Yanhua Lai
BJBinguang Jia
Binguang Jia
RCRu Chen
Ru Chen
XHXiaoyang Hui
Xiaoyang Hui

1 October 2025 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
BJBinguang Jia
Binguang Jia
ZSZiye Song
Ziye Song
XLXiao Li
Xiao Li
ZHZhipeng Hu
Zhipeng Hu
QLQiang Li
Qiang Li

23 April 2019 in International Journal of Food Engineering
Verified
Journal Article
Closed access
PDF file
DWDa Wang
Da Wang
YLYanhua Lai
Yanhua Lai
HZHongxia Zhao
Hongxia Zhao
BJBinguang Jia
Binguang Jia
QWQiang Wang
Qiang Wang
XYXiangzheng Yang
Xiangzheng Yang
The numerical simulation model of forced-air cooling of strawberries in a clamshell and a box was established by using computational fluid dynamics method. The cooling process of the simulation and the experiment results agreed well in different conditions, indicating that the simulation model was validated. The results showed that the 7/8 cooling time was 180 min, 135 min, 108 min and 100 min and the cooling uniformity coefficients were 0.31, 0.22, 0.24, 0.26 when the diameters of B-vent(the vent on the box) were 30 mm, 40 mm, 50 mm, 60 mm, respectively. The 7/8 cooling time decreased and the cooling uniformity coefficient improved, when the shape of C-vent (the vent on the clamshell) changed from round to rectangular. The 7/8 cooling time also deceased and the cooling uniformity coefficient increased, when the area of C-vent with both round and rectangular shapes increased. These results indicate that both B-vent and C-vent had significant effect on reducing the cooling time and the improving cooling uniformity for strawberries, It is suggested that the optimized vent ratio of B-vent (the diameter is 40 mm) and C-vent (15 mm round or 20 mm × 15 mm rectangular) for the current commercial packaged strawberries were 9.4 % and 8.5 %, respectively.

1 January 2017 in Procedia Engineering
Verified
Journal Article
Open access
FLFang Liu
Fang Liu
BJBinguang Jia
Binguang Jia
BCBaoming Chen
Baoming Chen
WGWenguang Geng
Wenguang Geng

14 May 2026 in Case Studies in Thermal Engineering
Verified
Journal Article
Open access
BJBinguang Jia
Binguang Jia
ZZZiyu Zhao
Ziyu Zhao
XWXiaolong Wang
Xiaolong Wang
CCChao Chen
Chao Chen
XMXiaoxuan Ma
Xiaoxuan Ma
NPNatalia Politaeva
Natalia Politaeva