Noroviruses (NoV), which are members of the family Caliciviridae , are the most important cause of outbreaks of acute gastroenteritis worldwide and are commonly found in shellfish grown in polluted waters. In the present study, we developed broadly reactive one-step TaqMan reverse transcription (RT)-PCR assays for the detection of genogroup I (GI) and GII NoV in fecal samples, as well as shellfish samples. The specificity and sensitivity of all steps of the assays were systematically evaluated, and in the final format, the monoplex assays were validated by using RNA extracted from a panel of 84 stool specimens, which included NoV strains representing 19 different genotypes (7 GI, 11 GII, and 1 GIV strains). The assays were further validated with 38 shellfish cDNA extracts previously tested by nested PCR. Comparison with a recently described real-time assay showed that our assay had significantly higher sensitivity and was at least as sensitive as the nested PCR. For stool specimens, a one-step duplex TaqMan RT-PCR assay performed as well as individual genogroup-specific monoplex assays. All other enteric viruses examined were negative, and no cross-reaction between genogroups was observed. These TaqMan RT-PCR assays provide rapid (less than 90 min), sensitive, and reliable detection of NoV and should prove to be useful for routine monitoring of both clinical and shellfish samples.
1 June 2005 in Applied and Environmental Microbiology
A quantitative real-time TaqMan PCR assay for detection of human adenoviruses (HAdV) was developed using broadly reactive consensus primers and a TaqMan probe targeting a conserved region of the hexon gene. The TaqMan assay correctly identified 56 representative adenovirus prototype strains and field isolates from all six adenovirus species (A to F). Based on infectious units, the TaqMan assay was able to detect as few as 0.4 and 0.004 infectious units of adenovirus serotype 2 (AdV2) and AdV41, respectively, with results obtained in less than 90 min. Using genomic equivalents, the broadly reactive TaqMan assay was able to detect 5 copies of AdV40 (which had zero mismatches with the PCR primers and probe), 8 copies of AdV41, and 350 copies of AdV3 (which had the most mismatches [seven] of any adenovirus serotype tested). For specific detection and identification of F species serotypes AdV40 and AdV41, a second real-time PCR assay was developed using fluorescence resonance energy transfer (FRET) probes that target the adenovirus fiber gene. The FRET-based assay had a detection limit of 3 to 5 copies of AdV40 and AdV41 standard DNA and was able to distinguish between AdV40 and AdV41 based on melting curve analysis. Both the TaqMan and FRET PCR assays were quantitative over a wide range of virus titers. Application of these assays for detection of adenoviruses and type-specific identification of AdV40 and AdV41 will be useful for identifying these viruses in environmental and clinical samples.
The ability to simultaneously concentrate diverse microbes is an important consideration for sample collection methods that are used for emergency response and environmental monitoring when drinking water may be contaminated with an array of unknown microbes. This study focused on developing a concentration method using ultrafilters and different combinations of a chemical dispersant (sodium polyphosphate [NaPP]) and surfactants. Tap water samples were seeded with bacteriophage MS2, Escherichia coli , Enterococcus faecalis , Cryptosporidium parvum , 4.5-μm microspheres, Salmonella enterica serovar Typhimurium, Bacillus globigii endospores, and echovirus 1. Ten-liter tap water samples were concentrated to ∼250 ml in 12 to 42 min, depending on the experimental condition. Initial experiments indicated that pretreating filters with fetal bovine serum or NaPP resulted in an increase in microbe recovery. The addition of NaPP to the tap water samples resulted in significantly higher microbe and microsphere recovery efficiencies. Backflushing of the ultrafilter was found to significantly improve recovery efficiencies. The effectiveness of backflushing was improved further with the addition of Tween 80 to the backflush solution. The ultrafiltration method developed in this study, incorporating the use of NaPP pretreatment and surfactant solution backflushing, was found to recover MS2, C. parvum , microspheres, and several bacterial species with mean recovery efficiencies of 70 to 93%. The mean recovery efficiency for echovirus 1 (49%) was the lowest of the microbes studied for this method. This research demonstrates that ultrafiltration can be effective for recovering diverse microbes simultaneously in tap water and that chemical dispersants and surfactants can be beneficial for improving microbial recovery using this technique.
1 July 2007 in Applied and Environmental Microbiology
Ultrafiltration (UF) is increasingly being recognized as a potentially effective procedure for concentrating and recovering microbes from large volumes of water and treated wastewater. Because of their very small pore sizes, UF membranes are capable of simultaneously concentrating viruses, bacteria, and parasites based on size exclusion. In this study, a UF-based water sampling procedure was used to simultaneously recover representatives of these three microbial classes seeded into 100-liter samples of tap water collected from eight cities covering six hydrologic areas of the United States. The UF-based procedure included hollow-fiber UF as the primary step for concentrating microbes and then used membrane filtration for bacterial culture assays, immunomagnetic separation for parasite recovery and quantification, and centrifugal UF for secondary concentration of viruses. Water samples were tested for nine water quality parameters to investigate whether water quality data correlated with measured recovery efficiencies and molecular detection levels. Average total method recovery efficiencies were 71, 97, 120, 110, and 91% for φX174 bacteriophage, MS2 bacteriophage, Enterococcus faecalis , Clostridium perfringens spores, and Cryptosporidium parvum oocysts, respectively. Real-time PCR and reverse transcription-PCR (RT-PCR) for seeded microbes and controls indicated that tap water quality could affect the analytical performance of molecular amplification assays, although no specific water quality parameter was found to correlate with reduced PCR or RT-PCR performance.