Susanne Lewin

Dr. Susanne Lewin

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 July 2015 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Closed access
PDF file
SMS.-I. Murtada
S.-I. Murtada
SLSusanne Lewin
Susanne Lewin
AAA. Arner
A. Arner
JHJ. D. Humphrey
J. D. Humphrey

2 July 2021 in Materials
Verified
Journal Article
Open access
PDF file
AGAna Grzeszczak
Ana Grzeszczak
SLSusanne Lewin
Susanne Lewin
OEOlle Eriksson
Olle Eriksson
JKJohan Kreuger
Johan Kreuger
Cecilia PerssonCecilia Persson
Cecilia Persson
Synthetic bone models are used to train surgeons as well as to test new medical devices. However, currently available models do not accurately mimic the complex structure of trabecular bone, which can provide erroneous results. This study aimed to investigate the suitability of stereolithography (SLA) to produce synthetic trabecular bone. Samples were printed based on synchrotron micro-computed tomography (micro-CT) images of human bone, with scaling factors from 1 to 4.3. Structure replicability was assessed with micro-CT, and mechanical properties were evaluated by compression and screw pull-out tests. The overall geometry was well-replicated at scale 1.8, with a volume difference to the original model of <10%. However, scaling factors below 1.8 gave major print artefacts, and a low accuracy in trabecular thickness distribution. A comparison of the model–print overlap showed printing inaccuracies of ~20% for the 1.8 scale, visible as a loss of smaller details. SLA-printed parts exhibited a higher pull-out strength compared to existing synthetic models (Sawbones ™), and a lower strength compared to cadaveric specimens and fused deposition modelling (FDM)-printed parts in poly (lactic acid). In conclusion, for the same 3D model, SLA enabled higher resolution and printing of smaller scales compared to results reported by FDM.

Verified
Journal Article
Open access
PDF file
SLSusanne Lewin
Susanne Lewin
PFPeter Försth
Peter Försth
Cecilia PerssonCecilia Persson
Cecilia Persson
Cement discoplasty has been developed to treat patients with advanced intervertebral disc degeneration. In discoplasty, poly(methylmethacrylate) (PMMA) bone cement is injected into the disc, leading to reduced pain and certain spinal alignment correction. Standard PMMA-cements have much higher elastic modulus than the surrounding vertebral bone, which may lead to a propensity for adjacent fractures. A PMMA-cement with lower modulus might be biomechanically beneficial. In this study, PMMA-cements with lower modulus were obtained using previously established methods. A commercial PMMA-cement (V-steady®, G21 srl) was used as control, and as base cement. The low-modulus PMMA-cements were modified by 12 vol% (LA12), 16 vol% (LA16) and 20 vol% (LA20) linoleic acid (LA). After storage in 37 °C PBS from 24 h up to 8 weeks, specimens were tested in compression to obtain the material properties. A lower E-modulus was obtained with increasing amount of LA. However, with storage time, the E-modulus increased. Standard and low-modulus PMMA discoplasty were compared in a previously developed and validated computational lumbar spine model. All discoplasty models showed the same trend, namely a substantial reduction in range of motion (ROM), compared to the healthy model. The V-steady model had the largest ROM-reduction (77%), and the LA20 model had the smallest (45%). The average stress at the endplate was higher for all discoplasty models than for the healthy model, but the stresses were reduced for cements with higher amounts of LA. The study indicates that low-modulus PMMA is promising for discoplasty from a mechanical viewpoint. However, validation experiments are needed, and the clinical setting needs to be further considered.

1 July 2021 in Acta Biomaterialia
Verified
Journal Article
Open access
SLSusanne Lewin
Susanne Lewin
LLLars Kihlström Burenstam Linder
Lars Kihlström Burenstam Linder
UBUlrik Birgersson
Ulrik Birgersson
SGSara Gallinetti
Sara Gallinetti
JÅJonas Åberg
Jonas Åberg
CÖCaroline Öhman-Mägi
Caroline Öhman-Mägi
The use of calcium phosphates (CaPs) as synthetic bone substitutes should ideally result in a volumetric balance with concomitant bone formation and degradation. Clinical data on such properties is nevertheless lacking, especially for monetite-based CaPs. However, a monetite-based composite implant has recently shown promising cranial reconstructions, with both CaP degradation and bone formation. In this study, the volumetric change at the implant site was quantified longitudinally by clinical computed tomography (CT). The retrospective CT datasets had been acquired postoperatively (n = 10), in 1-year (n = 9) and 3-year (n = 5) follow-ups. In the 1-year follow-up, the total volumetric change at the implant site was -8 ± 8%. A volumetric increase (bone formation) was found in the implant-bone interface, and a volumetric decrease was observed in the central region (CaP degradation). In the subjects with 2- or 3-year follow-ups, the rate of volumetric decrease slowed down or plateaued. The reported degradation rate is lower than previous clinical studies on monetite, likely due to the presence of pyrophosphate in the monetite-based CaP-formulation. A 31-months retrieval specimen analysis demonstrated that parts of the CaP had been remodeled into bone. The CaP phase composition remained stable, with 6% transformation into hydroxyapatite. In conclusion, this study demonstrates successful bone-bonding between the CaP-material and the recipient bone, as well as a long-term volumetric balance in cranial defects repaired with the monetite-based composite implant, which motivates further clinical use. The developed methods could be used in future studies for correlating spatiotemporal information regarding bone regeneration and CaP degradation to e.g. patient demographics. STATEMENT OF SIGNIFICANCE: In bone defect reconstructions, the use of calcium phosphate (CaP) bioceramics ideally results in a volumetric balance between bone formation and CaP degradation. Clinical data on the volumetric balance is nevertheless lacking, especially for monetite-based CaPs. Here, this concept is investigated for a composite cranial implant. The implant volumes were quantified from clinical CT-data: postoperatively, one year and three years postoperatively. In total, -8 ± 8% (n = 9) volumetric change was observed after one year. But the change plateaued, with only 2% additional decrease at the 3-year follow-up (n = 5), indicating a lower CaP degradation rate. Osseointegration was seen at the bone-implant interface, with a 9 ± 7% volumetric change after one year. This study presented the first quantitative spatiotemporal CT analysis of monetite-based CaPs.

1 April 2020 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
SLSusanne Lewin
Susanne Lewin
JÅJonas Åberg
Jonas Åberg
DNDominique Neuhaus
Dominique Neuhaus
HEHåkan Engqvist
Håkan Engqvist
SFStephen J. Ferguson
Stephen J. Ferguson
CPCecilia Persson
Cecilia Persson
Cranial implants are used to repair bone defects following neurosurgery or trauma. At present, there is a lack of data on their mechanical response, particularly in impact loading. The aim of the present study was to assess the mechanical response of a recently developed composite calcium phosphate-titanium (CaP-Ti) implant at quasi-static and impact loading rates. Two different designs were tested, referred to as Design 1 (D1) and Design 2 (D2). The titanium structures in the implant specimens were additively manufactured by a powder-bed fusion process and subsequently embedded in a self-setting CaP material. D1 was conceptually representative of the clinically used implants. In D2, the titanium structure was simplified in terms of geometry in order to facilitate the manufacturing. The mechanical response of the implants was evaluated in quasi-static compression, and in impact using a drop-tower. Similar peak loads were obtained for the two designs, at the two loading rates: 808 ± 29 N and 852 ± 34 for D1, and 840 ± 40 N and 814 ± 13 for D2. A strain rate dependency was demonstrated for both designs, with a higher stiffness in the impact test. Furthermore, the titanium in the implant fractured in the quasi-static test (to failure) but not in the impact test (to 5.75 J) for D1. For D2, the displacement at peak load was significantly lower in the impact test than in the quasi-static test. The main difference between the designs was seen in the quasi-static test results where the deformation zones, i.e. notches in the titanium structure between the CaP tiles, in D1 likely resulted in a localization of the deformation, compared to in D2 (which did not have deformation zones). In the impact test, the only significant difference between the designs was a higher maximum displacement of D2 than of D1. In comparison with other reported mechanical tests on osteoconductive ceramic-based cranial implants, the CaP-Ti implant demonstrates the highest reported strength in quasi-static compression. In conclusion, the titanium structure seems to make the CaP-Ti implant capable of cerebral protection in impact situations like the one tested in this study.

5 October 2017 in Biomedical Materials
Verified
Journal Article
Open access
PDF file
SLSusanne Lewin
Susanne Lewin
ABA Barba
A Barba
Cecilia PerssonCecilia Persson
Cecilia Persson
JFJ Franch
J Franch
Maria-Pau GinebraMaria-Pau Ginebra
Maria-Pau Ginebra
CÖCaroline Öhman-Mägi
Caroline Öhman-Mägi
There is a plethora of calcium phosphate (CaP) scaffolds used as synthetic substitutes to bone grafts. The scaffold performance is often evaluated from the quantity of bone formed within or in direct contact with the scaffold. Micro-computed tomography ( μ CT) allows three-dimensional evaluation of bone formation inside scaffolds. However, the almost identical x-ray attenuation of CaP and bone obtrude the separation of these phases in μ CT images. Commonly, segmentation of bone in μ CT images is based on gray scale intensity, with manually determined global thresholds. However, image analysis methods, and methods for manual thresholding in particular, lack standardization and may consequently suffer from subjectivity. The aim of the present study was to provide a methodological framework for addressing these issues. Bone formation in two types of CaP scaffold architectures (foamed and robocast), obtained from a larger animal study (a 12 week canine animal model) was evaluated by μ CT. In addition, cross-sectional scanning electron microscopy (SEM) images were acquired as references to determine thresholds and to validate the result. μ CT datasets were registered to the corresponding SEM reference. Global thresholds were then determined by quantitatively correlating the different area fractions in the μ CT image, towards the area fractions in the corresponding SEM image. For comparison, area fractions were also quantified using global thresholds determined manually by two different approaches. In the validation the manually determined thresholds resulted in large average errors in area fraction (up to 17%), whereas for the evaluation using SEM references, the errors were estimated to be less than 3%. Furthermore, it was found that basing the thresholds on one single SEM reference gave lower errors than determining them manually. This study provides an objective, robust and less error prone method to determine global thresholds for the evaluation of bone formation in CaP scaffolds.