Manuel Marques

Prof. Manuel Marques


Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2016 in Optics Express
Verified
Journal Article
Open access
PDF file
RARicardo M. André
Ricardo M. André
Stephen Warren-SmithStephen Warren-Smith
Stephen Warren-Smith
MBMartin Becker
Martin Becker
JDJan Dellith
Jan Dellith
MRManfred Rothhardt
Manfred Rothhardt
Orlando FrazãoOrlando Frazão
Orlando Frazão
Optical fiber micro-tips are promising devices for sensing applications in small volume and difficult to access locations, such as biological and biomedical settings. The tapered fiber tips are prepared by dynamic chemical etching, reducing the size from 125 μm to just a few μm. Focused ion beam milling is then used to create cavity structures on the tapered fiber tips. Two different Fabry-Perot micro-cavities have been prepared and characterized: a solid silica cavity created by milling two thin slots and a gap cavity. A third multi-cavity structure is fabricated by combining the concepts of solid silica cavity and gap cavity. This micro-tip structure is analyzed using a fast Fourier transform method to demultiplex the signals of each cavity. Simultaneous measurement of temperature and external refractive index is then demonstrated, presenting sensitivities of - 15.8 pm/K and −1316 nm/RIU, respectively.

11 December 2012 in IEEE Photonics Technology Letters
Verified
Journal Article
Closed access
RARicardo M. Andre
Ricardo M. Andre
CBClaudecir R. Biazoli
Claudecir R. Biazoli
SSSusana Silva
Susana Silva
MMManuel Marques
Manuel Marques
CCCristiano Cordeiro
Cristiano Cordeiro
Orlando FrazãoOrlando Frazão
Orlando Frazão
Tapering single-mode-multimode-single-mode structures to enhance sensitivity is proposed and experimentally demonstrated. 50-mm-long coreless multimode fiber sections are spliced between single-mode fibers (SMFs) and tapered. They are characterized in strain, and an increase in strain sensitivity is obtained with taper diameter reduction. Sensitivities as high as -23.69pm/με for the 15-μm taper are attained. Temperature sensitivities also depend on taper diameter. A combination of two different diameter tapered SMF MMF-SMF structures, with cross-sensitivity to strain and temperature, is proposed as a sensing system for the simultaneous measurement of strain and temperature with resolutions of ±5.6 με and ±1.6°C, respectively. A good condition number of 3.16 is achieved with this sensing structure.

1 November 2013 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
CGCarlos Gouveia
Carlos Gouveia
MZMohammad Zibaii
Mohammad Zibaii
HLHamid Latifi
Hamid Latifi
MMManuel Marques
Manuel Marques
José Manuel BaptistaJosé Manuel Baptista
José Manuel Baptista
Pedro JorgePedro Jorge
Pedro Jorge

22 August 2006 in European Journal of Inorganic Chemistry
Verified
Journal Article
Closed access
PDF file
João TedimJoão Tedim
João Tedim
SPSónia Gonçalves Patrício
Sónia Gonçalves Patrício
RBRosa Bessada
Rosa Bessada
RMRui Morais
Rui Morais
CSCarla Sousa
Carla Sousa
Cristina FreireCristina Freire
Cristina Freire

22 May 2014 in Optics Express
Verified
Journal Article
Closed access
PDF file
RARicardo M. André
Ricardo M. André
SPSimon Pevec
Simon Pevec
MBMartin Becker
Martin Becker
JDJan Dellith
Jan Dellith
MRManfred Rothhardt
Manfred Rothhardt
Orlando FrazãoOrlando Frazão
Orlando Frazão
Focused ion beam technology is combined with chemical etching of specifically designed fibers to create Fabry-Perot interferometers. Hydrofluoric acid is used to etch special fibers and create microwires with diameters of 15 μm. These microwires are then milled with a focused ion beam to create two different structures: an indented Fabry-Perot structure and a cantilever Fabry-Perot structure that are characterized in terms of temperature. The cantilever structure is also sensitive to vibrations and is capable of measuring frequencies in the range 1 Hz – 40 kHz.

10 June 1991 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
MMManuel Marques
Manuel Marques
GAG. Assanto
G. Assanto
GSG. I. Stegeman
G. I. Stegeman
GMG. R. Möhlmann
G. R. Möhlmann
EEE. W. P. Erdhuisen
E. W. P. Erdhuisen
WHW. H. G. Horsthuis
W. H. G. Horsthuis
We report the experimental evaluation of the intensity‐dependent index of refraction of a new class of third order nonlinear materials, side chain polymers containing 4‐dialkylamino‐4’‐nitro‐stilbene and 4‐dialkylamino‐4’‐nitro‐diphenylbutadiene as side groups. The measurements, based on nonlinear grating coupling into planar waveguides with 30 ps pulses at 1.064 μm, showed large electronic nonresonant n2 Kerr coefficients.