Dennis Severin Hansen

Mr. Dennis Severin Hansen

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 November 2023 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Open access
KSKenneth René Simonsen
Kenneth René Simonsen
DHDennis Severin Hansen
Dennis Severin Hansen
SPSimon Pedersen
Simon Pedersen

10 October 2023 in Journal of Environmental Management
Verified
Journal Article
Closed access
DHDennis Severin Hansen
Dennis Severin Hansen
ATAriel E. Turcios
Ariel E. Turcios
AKAnna-Marie Klamt
Anna-Marie Klamt
CWChristian Wieth
Christian Wieth
KRKasper Reitzel
Kasper Reitzel
Jutta PapenbrockJutta Papenbrock
Jutta Papenbrock

1 January 2015 in IFAC-PapersOnLine
Verified
Journal Article
Open access
PLPetar Durdevic Løhndorf
Petar Durdevic Løhndorf
SPSimon Pedersen
Simon Pedersen
MBMads Valentin Bram
Mads Valentin Bram
DHDennis Severin Hansen
Dennis Severin Hansen
AHAbdiladif Hassan
Abdiladif Hassan
ZYZhenyu Yang
Zhenyu Yang

12 February 2021 in Energies
Verified
Journal Article
Open access
PDF file
DHDennis Severin Hansen
Dennis Severin Hansen
MBMads Valentin Bram
Mads Valentin Bram
SLSteven Lauridsen
Steven Lauridsen
ZYZhenyu Yang
Zhenyu Yang
The importance and awareness of accurate online water quality measurements increase every year in the oil and gas sector, whether it is for reducing oil discharge, preparing produced water for reinjection, or improving operational performance. For online measurement techniques to yield valuable analytical information, an understanding of their outputs must be established. Produced water reinjection has gained increasing attention in the last decade, as it can minimize negative environmental impacts by reducing oil discharge and has the potential to extend the economic life of reservoirs. To increase the amount of produced water that can be reinjected, the water must be maintained at a sufficient quality to prevent unintended formation damage. This review paper thoroughly describes different water quality issues related to suspended solids that can occur in an injection water treatment system and how the issues are often interlinked. A case study of measuring the total suspended solids concentration of seawater sampled from the Danish sector of the North Sea has been carried out to effectively quantify water quality in an injection water treatment facility. Furthermore, numerous on- and in-line techniques have been evaluated as candidates for measuring suspended solids. The last part of the paper discusses considerations regarding future microscopy analyzers based on five promising online microscopy technologies.

19 August 2020 in Processes
Verified
Journal Article
Open access
PDF file
MBMads Valentin Bram
Mads Valentin Bram
SJStefan Jespersen
Stefan Jespersen
DHDennis Severin Hansen
Dennis Severin Hansen
ZYZhenyu Yang
Zhenyu Yang
As the treated water from offshore oil and gas production is discharged to the surrounding sea, there is an incentive to improve the performance of the offshore produced water treatment, to reduce the environmental pollutants to the sea. Regulations determine both the maximum allowed oil concentration and the total annual quantity. It is reasonable to assume that when better separation equipment or methods are developed, the regulation will become more strict, and force other producers to follow the trend towards zero harmful discharge. This paper develops and validates a hydrocyclone model to be used as a test-bed for improved control designs. The modeling methodology uses a combination of first-principles to define model structure and data-driven parameter identification. To evaluate and validate the separation performance, real-time fluorescence-based oil-in-water (OiW) concentration monitors, with dual redundancy, are installed and used on sidestreams of a modified pilot plant. The installed monitors measure the inlet and outlet OiW concentration of the tested hydrocyclone. The proposed control-oriented hydrocyclone model proved to be a reasonable candidate for predicting the hydrocyclone separation performance.

8 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
DHDennis Severin Hansen
Dennis Severin Hansen
SJStefan Jespersen
Stefan Jespersen
MBMads Valentin Bram
Mads Valentin Bram
ZYZhenyu Yang
Zhenyu Yang
Offshore oil and gas facilities are currently measuring the oil-in-water (OiW) concentration in the produced water manually before discharging it into the ocean, which in most cases fulfills the government regulations. However, as stricter regulations and environmental concerns are increasing over time, the importance of measuring OiW in real-time intensifies. The significant amount of uncertainties associated with manual samplings, that is currently not taken into consideration, could potentially affect the acceptance of OiW monitors and lower the reputation of all online OiW measurement techniques. This work presents the performance of four fluorescence-based monitors on an in-house testing facility. Previous studies of a fluorescence-based monitor have raised concerns about the measurement of OiW concentration being flow-dependent. The proposed results show that the measurements from the fluorescence-based monitors are not or insignificantly flow-dependent. However, other parameters, such as gas bubbles and droplet sizes, do affect the measurement. Testing the monitors’ calibration method revealed that the weighted least square is preferred to achieve high reproducibility. Due to the high sensitivity to different compositions of atomic structures, other than aromatic hydrocarbons, the fluorescence-based monitor might not be feasible for measuring OiW concentrations in dynamic separation facilities with consistent changes. Nevertheless, they are still of interest for measuring the separation efficiency of a deoiling hydrocyclone to enhance its deoiling performance, as the separation efficiency is not dependent on OiW trueness but rather the OiW concentration before and after the hydrocyclone.