Gintautas Palubinskas

Dr. Gintautas Palubinskas

DLR

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 March 2016 in International Journal of Image and Data Fusion
Verified
Journal Article
Closed access
GPGintautas Palubinskas
Gintautas Palubinskas
Similarity/distance measures play an important role in various signal/image processing applications such as classification, clustering, change detection and matching. In most cases, maybe excluding visual perception, the distance measure should be amplitude/intensity translation invariant what means that it depends only on the relative difference of compared variables/parameters, but not on their absolute values. The two most popular measures: mean squared error (MSE) and structural similarity (SSIM) index used in image processing have been analysed theoretically and experimentally by showing their origin, similarities/differences and main properties. Both measures depend on the same parameters: sample means, standard deviations and correlation coefficient. It has been shown that SSIM originates from the two generalised Dice measures and thus inherit their main property scale invariance. Consequently, this property leads to the dependence of the measure on absolute mean and standard deviation values. Similarly, MSE depends on the absolute standard deviation values. A new composite similarity/distance measure based on means, standard deviations and correlation coefficient (CMSC) which has been proposed recently exhibits translation invariance property with respect to means and standard deviations. Experiments on simulated and real data corrupted with various types of distortions: mean shift, contrast stretching, noise (additive/multiplicative, impulsive) and blurring, supported theoretical results.

21 July 2015 in Remote Sensing
Verified
Journal Article
Open access
PDF file
GPGintautas Palubinskas
Gintautas Palubinskas
A new Joint Quality Measure (JQM), which is a sole measure, is proposed for quality ranking of pansharpening methods. It is based on a newly proposed Composite similarity measure, which consists of Means, Standard deviations and Correlation coefficient (CMSC), and is translation invariant with respect to means and standard deviations. The JQM itself consists of a weighted sum of two terms. The first term is measured between a low pass filtered pansharpened image and original multispectral image at a reduced/low resolution scale. The second term is measured between the intensity calculated from spectrally weighted pansharpened multispectral image and original panchromatic image in a high resolution scale. Experimental results show advantages of a new measure, JQM, for quality assessment of pansharpening methods on the one hand, and drawbacks or unexpected properties of the already known measure, Quality with No Reference (QNR), on the other hand.

29 July 2010 in International Journal of Image and Data Fusion
Verified
Journal Article
Closed access
GPGintautas Palubinskas
Gintautas Palubinskas
PRPeter Reinartz
Peter Reinartz
RBRichard Bamler
Richard Bamler
Fusion of optical and radar remote sensing data is becoming an actual topic of discussion recently in various application areas though the results are not always satisfactory. In this article, we analyse some disturbing aspects of fusing orthoimages from sensors having different acquisition geometries. These aspects arise due to errors in digital elevation models (DEM), used for image orthorectification, and the existence of 3-D objects in the scene which are not accounted in the DEM. We analyse how these effects influence the ground displacement in orthoimages produced from optical and radar data. Further, we propose sensor formations with acquisition geometry parameters which allow to minimise or compensate for ground displacements in different orthoimages due to the above-mentioned effects and to produce good prerequisites for the following fusion for specific application areas, e.g. matching, filling data gaps, classification, etc. To demonstrate the potential of the proposed approach, two pairs of optical–radar data were acquired over the urban area–Munich City, Germany. The first collection of WorldView-1 and TerraSAR-X (TS-X) data followed the proposed recommendations for acquisition geometry parameters, whereas the second collection of IKONOS and TS-X data was acquired with accidental parameters. The experiment confirmed our ideas fully. Moreover, it opens new possibilities for optical and radar image fusion.

1 January 2008
Verified
Conference Paper
Closed access
GPGintautas Palubinskas
Gintautas Palubinskas
FKFranz Kurz
Franz Kurz
PRPeter Reinartz
Peter Reinartz
A new approach for the traffic congestion detection in time series of optical digital camera images is proposed. It is well suited to derive various traffic parameters such as vehicle density, average vehicle velocity, beginning and end of congestion, length of congestion or for other traffic monitoring applications. The method is based on the vehicle detection on the road segment by change detection between two images with a short time lag, the usage of a priori information such as road data base, vehicle sizes and road parameters and a simple linear traffic model based on the spacing between vehicles. The estimated velocity profiles for experimental data acquired by airborne optical remote sensing sensor - 3 K camera system - coincide quite well with the reference measurements.

2 April 2010 in European Transport Research Review
Verified
Journal Article
Open access
PDF file
GPGintautas Palubinskas
Gintautas Palubinskas
FKFranz Kurz
Franz Kurz
Peter ReinartzPeter Reinartz
Peter Reinartz
A new model based approach for the traffic congestion detection in time series of airborne optical digital camera images is proposed. It is based on the estimation of the average vehicle speed on road segments. The method puts various techniques together: the vehicle detection on road segments by change detection between two images with a short time lag, the usage of a priori information such as road data base, vehicle sizes and road parameters and a simple linear traffic model based on the spacing between vehicles. The estimated speed profiles from experimental data acquired by an airborne optical sensor - 3K camera system - coincide well with the reference measurements. Experimental results show the great potential of the proposed method for the detection of traffic congestion on highways in along-track scenes.

1 June 2015 in International Journal of Image and Data Fusion
Verified
Journal Article
Closed access
GPGintautas Palubinskas
Gintautas Palubinskas
We propose to look at multi-resolution image fusion or pan-sharpening task from a model-based perspective. Explicit definition of all models or assumptions used in the derivation of a fusion method allows us to understand the rationale or properties of existing methods and shows a way for a proper usage or proposal/selection of new methods better satisfying the needs of a particular application. Earlier mentioned property ‘better’ should be measurable quantitatively, e.g. by means of so-called quality measures. The difficulty of a quality assessment task in multi-resolution image fusion is that a reference image is missing. Existing measures or so-called protocols are still not satisfactory because quite often the rationale or assumptions are not valid or not fulfilled. From a model-based view, it follows naturally that a quality assessment measure can be defined as a combination of error model residuals using common or general models assumed in fusion methods. It is shown that most existing methods based on a spectral transformation or filtering are model-based methods. Unfortunately, it was found out that they are based additionally on a pure pixels assumption. Application of such methods for mixed pixels can lead to wrong fusion results. Model-based view analysis shows which methods respect models assumed and thus can help to select methods which deliver correct or physically justified fusion results.