Marko Štrok

Dr. Marko Štrok


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2011 in Chemosphere
Verified
Journal Article
Closed access
MŠMarko Štrok
Marko Štrok
BSBorut Smodiš
Borut Smodiš

1 December 2014 in Analytica Chimica Acta
Verified
Journal Article
Closed access
MŠMarko Štrok
Marko Štrok
HHHolger Hintelmann
Holger Hintelmann
BDBrian Dimock
Brian Dimock

1 January 2010 in Journal of Environmental Radioactivity
Verified
Journal Article
Closed access
MŠMarko Štrok
Marko Štrok
BSBorut Smodiš
Borut Smodiš

17 July 2019 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
LRLeja Rovan
Leja Rovan
MŠMarko Štrok
Marko Štrok
This study quantifies the behaviour of uranium isotope ratios (235U/238U and 234U/238U) with different aqueous sample preparation and separation techniques using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS) measurements and optimization of the MC-ICP-MS measurement protocol to obtain high precision and accuracy for uranium isotope ratios. The obtained results were compared with reference values, and they show that different sample preparation and separation methods influence the uranium isotopic composition and consequently the final results of unknown samples. The analytical procedure with the highest achievable precision and accuracy for uranium isotopes was the combination of coprecipitation with Ca3(PO4)2 and extraction chromatography with precleaned UTEVA resins. The combination of coprecipitation with Fe(OH)3 and ion exchange chromatography (DOWEX resins) provided the lowest achievable accuracy for uranium isotopes. The results reveal the extent of uranium biases during different physicochemical processing of samples in the range of −254 to 2.60‰ for 235U/238U and −299 to 8.90‰ for 234U/238U. A combination of sample preparation and measurement protocol optimization is of importance for various applications requiring extensive sample pre-treatment procedures where the 233U/236U double spike method for correcting for mass bias during sample preparation and separation steps is not feasible and to establish a methodology which enables the accurate determination of uranium isotope ratios in low-level concentration samples.

1 August 2012 in Journal of Environmental Radioactivity
Verified
Journal Article
Closed access
MŠMarko Štrok
Marko Štrok
BSBorut Smodiš
Borut Smodiš

1 June 2019 in Science of The Total Environment
Verified
Journal Article
Closed access
MŠMarko Štrok
Marko Štrok
PBPascale Anabelle Baya
Pascale Anabelle Baya
DDDörthe Dietrich
Dörthe Dietrich
BDBrian Dimock
Brian Dimock
HHHolger Hintelmann
Holger Hintelmann