In this work, the thermo-optic coefficient of silica fiber is analyzed and measured within a wide temperature range of 0-1200 °C for the first time. To obtain the thermo-optic coefficient, experiments were carried out by using fiber optic extrinsic Fabry-Perot interferometers (EFPIs) embedded in silica fiber. The optical cavity lengths of the EFPIs were measured with white-light interferometry. The experimental results show that the first and second orders of the thermo-optic coefficient are 1.090×10-5/°C and 1.611×10-9/°C2, respectively. The quadratic model for the temperature dependence of the basic optical parameter, the refractive index, is rigorous within a wide temperature range. Further, our work also provides a temperature calibration method for extrinsic Fabry-Perot interferometric temperature sensors. The temperatures measured by the sensors are in excellent agreement with those measured by the reference thermocouple. Hence, this calibration method is promising for temperature sensors with a wide working temperature range.
6 December 2018 in IEEE Photonics Technology Letters
A fiber-optic dual-cavity Fabry-Perot interferometric sensor for the simultaneous measurement of temperature and pressure is proposed and experimentally demonstrated. The sensor cascades a fiber-optic intrinsic Fabry-Perot interferometer (IFPI) and an extrinsic Fabry-Perot interferometer (EFPI). The IFPI is used as the temperature sensor and the EFPI is used as the pressure sensor. The pressure sensor is based on a diaphragm-free structure and can work stably at high temperature. Two optical path differences are interrogated simultaneously by using the fast Fourier transform-based white-light interferometry and the peak-to-peak method. Experimental results show that the proposed sensor exhibits a temperature sensitivity of 29.63 nm/°C within the temperature range of 40 °C-1100 °C and a pressure sensitivity of 1465.8 nm/MPa within the pressure range of 0-10 MPa at the room temperature.
A sapphire fiber high-temperature vibration sensor with an extrinsic Fabry-Perot interferometer (EFPI) structure is proposed and experimentally demonstrated. The vibrating diaphragm of the sensor is a supported beam structure fabricated by etching a single-side polished sapphire wafer using a femtosecond laser. The FP cavity of the sensor is composed of the sapphire fiber end face and the polished surface of the vibrating diaphragm. The interference signal of the sensor is picked up by the sapphire fiber and transmitted to a laser interferometry demodulator through a multimode fiber. Experimental results show that the acceleration response is linear in the range of 0-10 g along with an acceleration sensitivity of 20.91 nm/g. The resonance frequency of the sensor is 2700 Hz, which is consistent with the ANSYS simulation results. The sensor can also work in the temperature range from room temperature to 1500 ℃, providing a feasible method for vibration measurements in high-temperature environments.
A fiber optic dual-cavity Fabry–Perot interferometer (DFPI) for simultaneous high- temperature and high-gas-pressure measurements is proposed and experimentally demonstrated. The proposed sensing structure consists of an extrinsic Fabry–Perot interferometer (EFPI) with a short piece of hollow core fiber (HCF) for gas pressure sensing, and an intrinsic Fabry–Perot interferometer (IFPI) made of photonic crystal fiber (PCF) for temperature sensing. The composite interference signal is filtered in the frequency domain to obtain two independent interference spectra, and then is demodulated by using white light interferometry (WLI). The experimental results show that the sensor exhibits good linearity over a temperature range from 40 to 1000°C with a cavity-length temperature sensitivity of 25.3 nm/°C, and a pressure range from 0 to 10 MPa with a cavity-length pressure sensitivity of 1460 nm/MPa at 40°C. This proposed sensor are light-weight and small, and it has a compact structure and a high temperature resistance.
A fiber-optic hybrid sensor based on dual-cavity Fabry-Perot interferometers is proposed and demonstrated for the simultaneous measurement of high temperature and high pressure. The proposed sensor is fabricated by fusion splicing of two single-mode fibers (SMFs), a hollow core fiber (HCF), and a coreless fiber (CF), forming a four-section structure of leading SMF-SMF-HCF-CF. A micro-hole is fabricated at the end of the leading SMF using a femtosecond laser, forming an air gap between two SMFs. The CF is thinned and roughened by the femtosecond laser to form a diaphragm. The SMF-based cavity is used as the temperature sensor and the HCF-based cavity as the pressure sensor. Lengths of two cavities are interrogated simultaneously by using the fast Fourier transform-based white-light interferometry. Experimental results show that the proposed sensor exhibits a temperature sensitivity of 19.8 nm/°C and a pressure sensitivity of ~98 nm/MPa, within the temperature range of 20 °C-800 °C and the pressure range of 0-10 MPa. The maximum measurement errors of temperature and pressure are 5 °C and 0.2 MPa, respectively. As far as we know, it is the first time to detect the temperature of 800 °C and the pressure of 10 MPa simultaneously.
A phase demodulator for fiber optic extrinsic Fabry-Perot interferometric (EFPI) sensors is proposed for dynamic signal (vibration, acoustic, etc.) measurements. Three interferometric signals with phase differences are introduced by three lasers with different wavelengths. The tangent of the desired dynamic signal is extracted from the three interferometric signals. Then, the phase modulation is recovered by the arctangent algorithm and phase unwrapping. For the technique, constant phase differences are not required. Theoretically, the phase demodulator can interrogate EFPIs with arbitrary initial cavity length. The phase demodulator can perform regardless of whether the EFPI is modulated with a phase shift >2π or not. Dynamic signals are recovered successfully from EFPIs with cavity lengths ranging from 23.065 μm to 1094.703 μm by the same demodulator. As a passive demodulation method, the proposed demodulator is adapted to the detection of high frequency signals. A sinewave with a frequency of 20 kHz is extracted successfully. The algorithm of the technique is simple, robust, and provides great liberty with respect to choosing different sensors in different applications.