Activity concentrations of 234U, 235U, 238U, 226Ra, 228Ra, 222Rn, 210Po, 210Pb, 40K, 3H, 14C, 134Cs and 137Cs were determined in 20 different Japanese bottled drinking water commercially available in Japan. The origins of the mineral water samples were geographically distributed across different regions of Japan. Activity concentrations above detection limits were measured for the radionuclides 234U, 235U, 238U, 226Ra, 228Ra and 210Po. An average total annual effective dose due to ingestion was estimated for adults, based on the average annual volume of bottled water consumed in Japan in 2019, reported to be 31.7 L/y per capita. The estimated dose was found to be below the recommended World Health Organisation (WHO) guidance level of 0.1 mSv/y for drinking water quality. The most significant contributor to the estimated dose was 228Ra.
Wearable radiation detection systems are increasingly used in environmental monitoring and security applications; however, their capability for identifying medical radionuclides has received limited quantitative evaluation. Medical radionuclides may be encountered during radiation monitoring in clinical environments and in areas surrounding medical facilities, creating a need to assess how effectively they can be detected and identified. This work evaluates the performance of the Mirion SPIR-Pack Radiation Detector through assessments of directional response, dose rate accuracy, spectroscopic performance and radionuclide identification using calibrated reference sources and a range of medical radionuclides. During angular response testing, the detector exhibited a near-isotropic response, with measured dose rates remaining within ± 4.2 % of the reference dose value over most orientations. Energy calibration remained stable across the operating range of the detector, with photopeak deviations ranging from -0.25 % to -6.69 %, and the calculated resolution value at 662 keV from the resolution curve was consistent with expected NaI(Tl) behaviour. Medical radionuclide identification however was variable and depended on source activity and isotope library selection, with intrinsic energy resolution limiting peak discrimination in complex spectra. Overall, the SPIR-Pack demonstrated robust dose rate and spectroscopic performance, supporting its suitability for operational radiation monitoring, though the standard isotope libraries proved inadequate for reliable identification of several medical radionuclides, highlighting the importance of specialised isotope libraries.