René Poelma

René Poelma


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 February 2019 in Science Translational Medicine
Verified
Journal Article
Closed access
PDF file
ENEmile C. A. Nyns
Emile C. A. Nyns
RPRené Poelma
René Poelma
LVLinda Volkers
Linda Volkers
JPJaap J. Plomp
Jaap J. Plomp
CBCindy I. Bart
Cindy I. Bart
DPDaniël A. Pijnappels
Daniël A. Pijnappels
An implanted light source coupled with local gene therapy generates an automated shock-free system to treat atrial fibrillation in rats.

16 December 2019 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
BMBrahim El Mansouri
Brahim El Mansouri
LMLuke Middelburg
Luke Middelburg
RPRené Poelma
René Poelma
GZGuo Qi Zhang
Guo Qi Zhang
HZHenk W. van Zeijl
Henk W. van Zeijl
WDWillem Dirk Van Driel
Willem Dirk Van Driel
Commercially available gravimeters and seismometers can be used for measuring Earth’s acceleration at resolution levels in the order of $${\mathrm{ng}}/\sqrt {\mathrm{Hz}}$$ ng ∕ Hz (where g represents earth’s gravity) but they are typically high-cost and bulky. In this work the design of a bulk micromachined MEMS device exploiting non-linear buckling behaviour is described, aiming for $${\mathrm{ng}}/\sqrt {\mathrm{Hz}}$$ ng ∕ Hz resolution by maximising mechanical and capacitive sensitivity. High mechanical sensitivity is obtained through low structural stiffness. Near-zero stiffness is achieved through geometric design and large deformation into a region where the mechanism is statically balanced or neutrally stable. Moreover, the device has an integrated capacitive comb transducer and makes use of a high-resolution impedance readout ASIC. The sensitivity from displacement to a change in capacitance was maximised within the design and process boundaries given, by making use of a trench isolation technique and exploiting the large-displacement behaviour of the device. The measurement results demonstrate that the resonance frequency can be tuned from 8.7 Hz–18.7 Hz, depending on the process parameters and the tilt of the device. In this system, which combines an integrated capacitive transducer with a sensitivity of 2.55 aF/nm and an impedance readout chip, the theoretically achievable system resolution equals 17.02 $${\mathrm{ng}}/\sqrt {\mathrm{Hz}}$$ ng ∕ Hz . The small size of the device and the use of integrated readout electronics allow for a wide range of practical applications for data collection aimed at the internet of things.

17 July 2014 in Advanced Functional Materials
Verified
Journal Article
Closed access
PDF file
RPRené Poelma
René Poelma
BMBruno Morana
Bruno Morana
Delft University VollebregtDelft University Vollebregt
Delft University Vollebregt
Erik SchlangenErik Schlangen
Erik Schlangen
HZHenk W. van Zeijl
Henk W. van Zeijl
GZGuo Qi Zhang
Guo Qi Zhang

1 July 2012 in Microelectronics Reliability
Verified
Journal Article
Closed access
RPRené Poelma
René Poelma
HSH. Sadeghian
H. Sadeghian
SKS. Koh
S. Koh
GZG.Q. Zhang
G.Q. Zhang

3 May 2016 in Scientific Reports
Verified
Journal Article
Open access
XLXueming Li
Xueming Li
LWLei Wei
Lei Wei
RPRené Poelma
René Poelma
Delft University VollebregtDelft University Vollebregt
Delft University Vollebregt
JWJia Wei
Jia Wei
GZGuo Qi Zhang
Guo Qi Zhang
This paper presents a tuneable binary amplitude Fresnel lens produced by wafer-level microfabrication. The Fresnel lens is fabricated by encapsulating lithographically defined vertically aligned carbon nanotube (CNT) bundles inside a polydimethyl-siloxane (PDMS) layer. The composite lens material combines the excellent optical absorption properties of the CNT with the transparency and stretchability of the PDMS. By stretching the elastomeric composite in radial direction, the lens focal length is tuned. Good focusing response is demonstrated and a large focus change (≥24%) was achieved by stretching lenses up to 11.4%.

4 January 2016 in Advanced Functional Materials
Verified
Journal Article
Closed access
PDF file
RPRené Poelma
René Poelma
XFXuejun Fan
Xuejun Fan
ZHZhi‐Yi Hu
Zhi‐Yi Hu
GTGustaaf Van Tendeloo
Gustaaf Van Tendeloo
HZHenk W. van Zeijl
Henk W. van Zeijl
GZGuo Qi Zhang
Guo Qi Zhang