Denis Sodin

Mr. Denis Sodin

Jozef Stefan Institute
+1

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DSDenis Sodin
Denis Sodin
URUrban Rudez
Urban Rudez
MMMarko Mihelin
Marko Mihelin
MSMiha Smolnikar
Miha Smolnikar
AČAndrej Čampa
Andrej Čampa
The detection and localization of faults plays a huge role in every electric power system, be it a transmission network (TN) or a distribution network (DN), as it ensures quick power restoration and thus enhances the system’s reliability and availability. In this paper, a framework that supports phasor measurement unit (PMU)-based fault detection and localization is presented. Besides making the process of fault detecting, localizing and reporting to the control center fully automated, the aim was to make the framework viable also for DNs, which normally do not have dedicated fiber-optic connectivity at their disposal. The quality of service (QoS) for PMU data transmission, using the widespread long-term evolution (LTE) technology, was evaluated and the conclusions of the evaluation were used in the development of the proposed edge-cloud framework. The main advantages of the proposed framework can be summarized as: (a) fault detection is performed at the edge nodes, thus bypassing communication delay and availability issues, (b) potential packet losses are eliminated by temporally storing data at the edge nodes, (c) since the detection of faults is no longer centralized, but rather takes place locally at the edge, the amount of data transferred to the control center during the steady-state conditions of the network can be significantly reduced.

13 July 2020 in Energies
Verified
Journal Article
Open access
PDF file
DSDenis Sodin
Denis Sodin
RIRajne Ilievska
Rajne Ilievska
AČAndrej Čampa
Andrej Čampa
MSMiha Smolnikar
Miha Smolnikar
URUrban Rudez
Urban Rudez
It is widely recognized that in the transition from conventional electrical power systems (EPSs) towards smart grids, electrical voltage frequency will be greatly affected. This is why this research is extremely valuable, especially since rate-of-change-of-frequency (RoCoF) is often considered as a potential means of resolving newly arisen problems, but is often challenged in practice due to the noise and its oscillating character. In this paper, the authors further developed and tested one of the new technologies related to under-frequency load shedding (UFLS) protection. Since the basic idea was to enhance the selected technology’s readiness level, a hardware-in-the-loop (HIL) setup with an RTDS was assembled. The under-frequency technology was implemented in an intelligent electronic device (IED) and included in the HIL setup. The IED acted as one of several protection devices, representing a last-resort system protection scheme. All main contributions of this research deal with using RoCoF in an innovative UFLS scheme under test: (i) appropriate selection and parameterization of RoCoF filtering techniques does not worsen under-frequency load shedding during fast-occurring events, (ii) locally measured RoCoF can be effectively used for bringing a high level of flexibility to a system-wide scheme, and (iii) diversity of relays and RoCoF-measuring techniques is an advantage, not a drawback.