This study presents environmentally friendly snow melting methods utilizing electric heating cables, ground source heat pumps, tunnel water heat, solar-assisted electric heating cables, and boilers that have been developed and tested at several expressway sections in South Korea since 1996. Compared with a conventional winter maintenance practice based on deicing or anti-icing chemicals, these snow melting systems have little environmental impact (i.e., eco-melting) and are useful in clearing away snow and preventing ice formation promptly without causing long and frequent traffic hold-ups. A comparative evaluation on the eco-melting systems is conducted to characterize their construction and operation features, and the snow melting performance of each system is validated at full-scale test sites under various winter weather conditions. Also, cost analyses are conducted based on the data collected from the field experiments to determine the affordability of each system. Finally, five types of expressway sections (hi-pass toll lane, regular toll lane, an open section between tunnels, curved road, and bridge) that are vulnerable to traffic accidents during winter are prioritized based on three factors (safety, affordability, and environment) for the optimum deployment of eco-melting systems on modern expressways.
This study is a preliminary investigation of the independent utilization of two types of fly ash (FA)–FA Type C and FA Type F-as partial replacement of fine aggregate (sand) and cement in Portland cement concrete (PCC) mixes. The main objective was to determine an optimum substitution range for each type of FA that would offer well-performing concrete in terms of workability, compressive strength, and durability. To this end, multiple concrete batches were prepared, incorporating each type of FA at four different levels: 5%, 10%, 15%, and 20% by weight of fine aggregate replacement and 10%, 20%, 30%, and 40% by weight for cement replacement. Then, concrete samples (100 mm diameter × 200 mm tall cylinders) were cast from each batch and were moisture-cured for 7, 14, and 28 days prior to testing. The addition of FA contributed positively to the strength development at specific replacement levels: all percentages for both FA Type C and Type F for fine aggregate replacement and up to 30% FA content for both Type C and F for cement replacement, 10% for both FA Type C and Type F provided the higher strength for aggregate replacement, and 10–20% for both types of FA provided the higher strength for cement replacement. Furthermore, these additions of FA exhibited comparable workability and durability except for FA Type F, which did not exhibit comparable workability for aggregate replacement. FA Type C can be recommended for both early and long-term strength for fine aggregate replacement, whereas FA Type C is suggested to be used for early strength and Type F provides for long-term strength for cement replacement. Type C provides better durability and Type F provides better workability for cement replacement.
Ensuring the durability of concrete pavements against chloride ingress is critical, yet the relationship between electrical resistivity and chloride penetration remains underexplored. This study evaluates the effectiveness of entrained air and fly ash in mitigating chloride ingress using an electrical resistivity model and surface resistivity tests. Concrete samples with varying entrained air contents (0% to 10%) and Class C or Class F fly ash underwent three-year ponding tests in temperature-controlled indoor water baths and outdoor CaCl2-NaCl brine solutions. The results indicate that lower entrained air contents led to a more rapid increase in resistivity, with concrete mixes incorporating Class C fly ash exhibiting 1.5 times greater resistivity gains than those with Class F fly ash. Surface resistivity tests revealed that reaction factors were 67% higher in specimens with 3.5% entrained air compared to 10.0%, while decreasing by 57% and 41% in concrete mixes containing Class F and Class C fly ash, respectively, across all chloride concentrations. Using back-calculated environmental factors, corrosion initiation potential in concrete pavements was projected for exposure periods of up to 50 years. These findings provide insights for optimizing entrained air and fly ash formulations to enhance pavement performance and durability.
5 November 2025 in Case Studies in Construction Materials