Baolei Guo

Dr. Baolei Guo

Department of Vascular Surgery, Zhongshan Hospital, Fudan University, Shanghai, China

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 July 2018 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
CMClaudia Menichini
Claudia Menichini
SPSelene Pirola
Selene Pirola
BGBaolei Guo
Baolei Guo
WFWeiguo Fu
Weiguo Fu
ZDZhihui Dong Zhihui Dong
Zhihui Dong Zhihui Dong
XXXiao Yun Xu
Xiao Yun Xu
Purpose: To explore the potential role of morphological factors and wall stress in the formation of stent-graft–induced new entries (SINE) based on computed tomography (CT) images after thoracic endovascular aortic repair (TEVAR). Case Report: Two female patients aged 59 years (patient 1) and 44 years (patient 2) underwent TEVAR for type B dissection in the chronic (patient 1) or subacute (patient 2) phase. CT scans at 3-month follow-up showed varying degrees of false lumen thrombosis in both patients. At 14-month follow-up, a SINE was observed in patient 1 while the dissected aorta in the other patient remained stable. Morphological and finite element analyses were performed based on the first follow-up CT images. The computational results showed that the SINE patient had higher stent-graft tortuosity than the non-SINE patient and much higher wall stress in the region close to the distal SINE. Conclusion: This case study suggests that high stent-graft tortuosity can lead to high wall stress, which is potentially linked to the formation of SINE. Further large population-based studies are needed to confirm this preliminary finding.

19 July 2022 in Journal of Endovascular Therapy
Verified
Journal Article
Open access
CAChlöe Armour
Chlöe Armour
BGBaolei Guo
Baolei Guo
SSSimone Saitta
Simone Saitta
DGDaqiao Guo
Daqiao Guo
YLYifan Liu
Yifan Liu
XXXiao Yun Xu
Xiao Yun Xu
Purpose: False lumen (FL) expansion often occurs in type B aortic dissection (TBAD) and has been associated with the presence of re-entry tears. This longitudinal study aims to elucidate the role of re-entry tears in the progression of TBAD using a controlled swine model, by assessing aortic hemodynamics through combined imaging and computational modeling. Materials and Methods: A TBAD swine model with a primary entry tear at 7 cm distal to the left subclavian artery was created in a previous study. In the current study, reintervention was carried out in this swine model to induce 2 additional re-entry tears of approximately 5 mm in diameter. Computed tomography (CT) and 4-dimensional (4D) flow magnetic resonance imaging (MRI) scans were taken at multiple follow-ups before and after reintervention. Changes in aortic volume were measured on CT scans, and hemodynamic parameters were evaluated based on dynamic data acquired with 4D-flow MRI and computational fluid dynamics simulations incorporating all available in vivo data. Results: Morphological analysis showed FL growth of 20% following the initial TBAD—growth stabilized after the creation of additional tears and eventually FL volume reduced by 6%. Increasing the number of re-entry tears from 1 to 2 caused flow redistribution, with the percentage of true lumen (TL) flow increasing from 56% to 78%; altered local velocities; reduced wall shear stress surrounding the tears; and led to a reduction in FL pressure and pressure difference between the 2 lumina. Conclusion: This study combined extensive in vivo imaging data with sophisticated computational methods to show that additional re-entry tears can alter dissection hemodynamics through redistribution of flow between the TL and FL. This helps to reduce FL pressure, which could potentially stabilize aortic growth and lead to reversal of FL expansion. This work provides a starting point for further study into the use of fenestration in controlling undesirable FL expansion. Clinical Impact: Aortic growth and false lumen (FL) patency are associated with the presence of re-entry tears in type B aortic dissection (TBAD) patients. Guidelines on how to treat re-entry tears are lacking, especially with regards to the control and prevention of FL expansion. Through a combined imagining and computational hemodynamics study of a controlled swine model, we found that increasing the number of re-entry tears reduced FL pressure and cross lumen pressure difference, potentially stabilising aortic growth and leading to FL reduction. Our findings provide a starting point for further study into the use of fenestration in controlling undesirable FL expansion.

9 August 2022 in Frontiers in Cardiovascular Medicine
Verified
Journal Article
Open access
CCCan Chen
Can Chen
BPBenjamin Patterson
Benjamin Patterson
RSRuan Simpson
Ruan Simpson
YLYanli Li
Yanli Li
ZCZhangzhang Chen
Zhangzhang Chen
BGBaolei Guo
Baolei Guo
Objective: The aim of this study was to determine the association between fluoroquinolones (FQs) use, the risk of de novo aortic aneurysm or dissection (AAD), and the prognosis of patients with pre-existing AAD.Materials and methods: We searched PubMed, EMBASE, CENTRAL, Scopus, and Web of Science on 31 March 2022. Observational studies that evaluated the association of FQs with AAD risk in the general population or FQs with the prognosis of patients with preexisting AAD and presented adjusted effect estimates were included. Two reviewers assessed study eligibility, extracted data, and assessed the risk of bias and certainty of evidence using GRADE.Results: Of the 13 included studies, 11 focused on the association of FQs with de novo AAD incidence, and only one study investigated the association of FQs with the patient with AAD prognosis. FQ use was associated with an increased risk of de novo AAD within 30 days (RR: 1.42; 95% CI: 1.11–1.81; very low certainty) and 60 days (RR: 1.44; 95% CI: 1.26–1.64; low certainty). Specifically, the association was significant when compared with amoxicillin, azithromycin, doxycycline, or no antibiotic use. Furthermore, patients with preexisting AAD exposure to FQ had an increased risk of all-cause mortality (RR: 1.61; 95% CI: 1.50–1.73; moderate certainty) and aortic-specific mortality (RR: 1.80; 95% CI: 1.50–2.15; moderate certainty), compared to the non-exposed FQ group within a 60-day risk period.Conclusion: FQs were associated with an increased incidence of AAD in the general population and a higher risk of adverse outcomes in patients with preexisting AAD. Nevertheless, the results may be affected by unmeasured confounding factors. This should be considered by physicians contemplating using FQs in patients with aortic dilation and those at high risk of AAD.Systematic Review Registration: [https://www.crd.york.ac.uk/prospero/], identifier [CRD42021230171].

8 October 2021 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
SSSimone Saitta
Simone Saitta
BGBaolei Guo
Baolei Guo
SPSelene Pirola
Selene Pirola
CMClaudia Menichini
Claudia Menichini
DGDaqiao Guo
Daqiao Guo
WFWeiguo Fu
Weiguo Fu
Objective: The interactions between aortic morphology and hemodynamics play a key role in determining type B aortic dissection (TBAD) progression and remodeling. The study aimed to provide qualitative and quantitative hemodynamic assessment in four different TBAD morphologies based on 4D flow MRI analysis.Materials and Methods: Four patients with different TBAD morphologies underwent CT and 4D flow MRI scans. Qualitative blood flow evaluation was performed by visualizing velocity streamlines and flow directionality near the tears. Quantitative analysis included flow rate, velocity and reverse flow index (RFI) measurements. Statistical analysis was performed to evaluate hemodynamic differences between the true lumen (TL) and false lumen (FL) of patients.Results: Qualitative analysis revealed blood flow splitting near the primary entry tears (PETs), often causing the formation of vortices in the FL. All patients exhibited clear hemodynamic differences between TL and FL, with the TL generally showing higher velocities and flow rates, and lower RFIs. Average velocity magnitude measurements were significantly different for Patient 1 (t = 5.61, p = 0.001), Patient 2 (t = 3.09, p = 0.02) and Patient 4 (t = 2.81, p = 0.03). At follow-up, Patient three suffered from left renal ischemia because of FL collapse. This patient presented a complex morphology with two FLs and marked flow differences between TL and FLs. In Patient 4, left renal artery malperfusion was observed at the 32-months follow-up, due to FL thrombosis growing after PET repair.Conclusion: The study demonstrates the clinical feasibility of using 4D flow MRI in the context of TBAD. Detailed patient-specific hemodynamics assessment before treatment may provide useful insights to better understand this pathology in the future.

1 December 2021 in European Journal of Vascular and Endovascular Surgery
Verified
Journal Article
Closed access
BGBaolei Guo
Baolei Guo
CCChen Can
Chen Can
LPLv Peng
Lv Peng
SYShan Yan
Shan Yan
YCYan Cheng
Yan Cheng
WFWeiguo Fu
Weiguo Fu

1 December 2020 in Journal of Vascular and Interventional Radiology
Verified
Journal Article
Closed access
BGBaolei Guo
Baolei Guo
DGDaqiao Guo
Daqiao Guo
BCBin Chen
Bin Chen
ZSZhenyu Shi
Zhenyu Shi
ZDZhihui Dong
Zhihui Dong
WFWeiguo Fu
Weiguo Fu