Chuansheng Zhang

Mr. Chuansheng Zhang

Guangxi university
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2020 in Polymers
Verified
Journal Article
Open access
PDF file
Hanbo ZhengHanbo Zheng
Hanbo Zheng
Chuansheng ZhangChuansheng Zhang
Chuansheng Zhang
Yiyi ZhangYiyi Zhang
Yiyi Zhang
Jiefeng LiuJiefeng Liu
Jiefeng Liu
EZenze zhang
enze zhang
CZchaohai zhang
chaohai zhang
The method using ethanol to evaluate the cellulose insulation aging condition of oil-immersed transformers has been proposed. At present, the dominating method for detecting ethanol in insulating oil is to use headspace–gas-chromatography–mass-spectrometry (HS-GC-MS). However, the problem of quantitative inaccuracy will be sometimes encountered in the actual detection process due to improper instrument parameter setting and improper manual operation. In this study, as an aging marker, ethanol in transformer insulating oil was separated by using VF-624 ms capillary column. The effects of gas-chromatography–mass-spectrometry (GC-MS) optimization conditions, headspace equilibrium temperature, headspace equilibrium time and standard solution preparation method on the determination of ethanol content in oil were discussed, and optimized measures were proposed. The experimental results showed that the measurement can be more accurate under the headspace temperature of 80 °C and the headspace time of 40 min, and relative standard deviation percentage (RSD%) could reach to 4.62% under this condition. It was also pointed out that, for the preparation of standard solution, the method which controlled the sampling volume of anhydrous ethanol by microliter syringe could make the peak area of ethanol chromatogram have a better linear relationship with the standard curve. Under the similar linear range, the goodness of fitting curve without diluting process could be as high as 0.9993, while the method of preparing the stock solution and diluting stepwise to obtain the fitting curve only had a goodness of 0.9910. The method was validated by standard addition recovery test, and the recovery values obtained were between 90.3% and 95.8%. The optimized method is of great significance for the measurement of ethanol dissolved in insulating oil.

1 September 2019
Verified
Conference Paper
Closed access
YCYulu Chen
Yulu Chen
WTWulin Tong
Wulin Tong
XYXiong Yang
Xiong Yang
BWBingbing Wang
Bingbing Wang
Chuansheng ZhangChuansheng Zhang
Chuansheng Zhang
XWXiaodong Wang
Xiaodong Wang
A novel Terahertz (THz) detector based on metallic gratings/GaAs-based Blocked Impurity Band (BIB) hybrid structure was designed and simulated in this work. By setting the periodic metallic gratings as 100μm with 50μm width, the absorption peak of the hybrid structure detector exists at the wavelength of 249 μm, which is 4.84 times larger than the conventional BIB detector. Also, the resonate absorption peak can be modulated by changing the period of metallic gratings. Our design and simulation result provide a new scheme to fabricate the high-performance THz detector for the practical applications such as security check, biomedical treatment, and astronomical obseveration etc.