Jonathan Murray

Dr. Jonathan Murray


Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2010 in Quarterly Journal of the Royal Meteorological Society
Verified
Journal Article
Open access
PDF file
CCCaroline Cox
Caroline Cox
JHJ. E. Harries
J. E. Harries
JTJ. P. Taylor
J. P. Taylor
PGP. D. Green
P. D. Green
ABA. J. Baran
A. J. Baran
JMJonathan Murray
Jonathan Murray
Observed far‐infrared and mid‐infrared radiance spectra measured insitu above cirrus with both the Tropospheric Airborne Fourier Transform Spectrometer (TAFTS) and the Airborne Research Interferometer Evaluation System (ARIES) are presented. Two sets of upwelling spectra between wavenumbers 100 and 1415cm−1 taken over ice cloud of visible optical thickness 0.1 and 0.3 are shown. These observations address the need for more measurements of radiance from cirrus, particularly in the far infrared, where experimental data are lacking. A test of consistency in modelling in both the far infrared and mid infrared is performed by fitting a model calculation of radiances in the infrared window region, and comparing with the measured radiances. In this consistency check, the sampling of the surrounding atmosphere and the cloud is given extensive consideration. The model was not able to consistently reproduce the observed radiance across the entire region, and was particularly poor in the 330–600cm−1 region of the far infrared. Possible causes are thought to be primarily model input uncertainties arising from inadequate sampling of cloud and atmosphere. Copyright © 2010 Royal Meteorological Society and Crown Copyright.

1 July 1994 in The Journal of Chemical Physics
Verified
Journal Article
Closed access
PDF file
JMJonathan Murray
Jonathan Murray
KYK. Yoshino
K. Yoshino
JEJ. R. Esmond
J. R. Esmond
WPW. H. Parkinson
W. H. Parkinson
YSY. Sun
Y. Sun
GCG. Cox
G. Cox
The combined band oscillator strength of the δ(0,0) and β(7,0) bands of nitric oxide has been measured in absorption by utilizing a vacuum ultraviolet Fourier transform spectrometer to resolve the rotational line profiles. We give accurate rotational line positions of the δ(0,0) and β(7,0) bands, and improved term values up to J=19.5 for the C 2Π(v=0) and J=8.5 for the B 2Π(v=7) levels, measured from the ground state. A deperturbation procedure has been used on the mixed levels, and the calculated molecular constants are in good agreement with previous work.

4 April 2002 in Monthly Notices of the Royal Astronomical Society
Verified
Journal Article
Open access
PDF file
JPJ. C. Pickering
J. C. Pickering
ATA. P. Thorne
A. P. Thorne
JMJonathan Murray
Jonathan Murray
ULU. Litzén
U. Litzén
SJS. Johansson
S. Johansson
JWJohn Webb
John Webb
The quality of astronomical spectroscopic data now available is so high that interpretation and analysis are often limited by the uncertainties of th

13 June 2012 in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
Verified
Journal Article
Closed access
PGPaul D. Green
Paul D. Green
SNStuart Newman
Stuart Newman
RBRalph J. Beeby
Ralph J. Beeby
JMJonathan Murray
Jonathan Murray
JPJuliet C. Pickering
Juliet C. Pickering
JHJohn E. Harries
John E. Harries
We present a new derivation of the foreign-broadened water vapour continuum in the far-infrared (far-IR) pure rotation band between 24 μm and 120 μm (85–420 cm−1) from field data collected in flight campaigns of the Continuum Absorption by Visible and IR radiation and Atmospheric Relevance (CAVIAR) project with Imperial College's Tropospheric Airborne Fourier Transform Spectrometer (TAFTS) far-IR spectro-radiometer instrument onboard the Facility for Airborne Atmospheric Measurement (FAAM) BAe-146 research aircraft; and compare this new derivation with those recently published in the literature in this spectral band. This new dataset validates the current Mlawer–Tobin-Clough–Kneizys–Davies (MT-CKD) 2.5 model parametrization above 300 cm−1, but indicates the need to strengthen the parametrization below 300 cm−1, by up to 50 per cent at 100 cm−1. Data recorded at a number of flight altitudes have allowed measurements within a wide range of column water vapour environments, greatly increasing the sensitivity of this analysis to the continuum strength.

22 July 1995 in The Journal of Chemical Physics
Verified
Journal Article
Closed access
PDF file
KYK. Yoshino
K. Yoshino
JEJ. R. Esmond
J. R. Esmond
JMJonathan Murray
Jonathan Murray
WPW. H. Parkinson
W. H. Parkinson
ATA. P. Thorne
A. P. Thorne
GCG. Cox
G. Cox
Photoabsorption cross section measurements of the Herzberg I bands (A3Σu+−X3Σg−) of O2 have been made by Fourier transform spectrometry with a resolution of 0.06 cm−1 in the wavelength region 240‐270 nm. Precise band oscillator strengths of the (4,0)–(11,0) bands are obtained by direct measurement, and for some of the strong bands, they are significantly higher than the previous experimental values. The rotational line strengths and the branching ratios are also presented for the same bands. The dissociation energy of O2 is discussed.

6 December 2007 in Quarterly Journal of the Royal Meteorological Society
Verified
Journal Article
Open access
PDF file
CCC. V. Cox
C. V. Cox
JMJonathan Murray
Jonathan Murray
JTJ. P. Taylor
J. P. Taylor
PGP. D. Green
P. D. Green
JPJ. C. Pickering
J. C. Pickering
ALA. E. Last
A. E. Last
Observed clear‐sky far‐infrared (FIR) radiances measured by the Tropospheric Airborne Fourier Transform Spectrometer (TAFTS) are presented. These measurements were taken when flying on board the Facility for Atmospheric Airborne Measurements British Aerospace 146 aircraft over the UK on 18 September 2004 in the upper troposphere between 8.3 and 9.2 km altitude, during the European AQUA Thermodynamic Experiment (EAQUATE). Upwelling clear‐sky measurements from the TAFTS short‐wave channel (330 to 500 cm−1) are shown and these measured radiances are compared to model radiances where various dropsonde data are incorporated. The variations in the water vapour profiles below the aircraft are explored in terms of the FIR spectra. The downwelling measurements from TAFTS long‐wave channel (90 to 230 cm−1) are also compared to model spectra, produced in this case from the UK Met Office (UKMO) mesoscale model. The variation in the UKMO mesoscale modelled downwelling radiance over the flight leg is seen to have a standard deviation of 0.5 to 2 mW (m2 sr cm−1)−1, that is of the order of TAFTS detection limit in this particular campaign. Copyright © 2007 Royal Meteorological Society