Jiaxi Li

Mr. Jiaxi Li


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 July 2020 in Polymers
Verified
Journal Article
Open access
PDF file
Yiyi ZhangYiyi Zhang
Yiyi Zhang
JLJiaxi Li
Jiaxi Li
Xianhao FanXianhao Fan
Xianhao Fan
Jiefeng LiuJiefeng Liu
Jiefeng Liu
HZHeng Zhang
Heng Zhang
The support vector machine (SVM) combined with the genetic algorithm (GA) has been utilized for the fault diagnosis of transformers since its high accuracy. In addition to the fault diagnosis, the condition assessment of transformer oil-immersed insulation conveys the crucial engineering significance as well. However, the approaches for getting GA-SVM used to the moisture prediction of oil-immersed insulation have been rarely reported. In view of this issue, this paper pioneers the application of GA-SVM and frequency domain spectroscopy (FDS) to realize the moisture prediction of transformer oil-immersed insulation. In the present work, a method of constructing a GA-SVM multi-classifier for moisture diagnosis based on the fitting analysis model is firstly reported. Then, the feasibility and reliability of the reported method are proved by employing the laboratory and field test experiments. The experimental results indicate that the reported prediction model might be serviced as a potential tool for the moisture prediction of transformer oil-immersed polymer insulation.

31 July 2020 in Polymers
Verified
Journal Article
Open access
PDF file
Yiyi ZhangYiyi Zhang
Yiyi Zhang
SLSheng Li
Sheng Li
Xianhao FanXianhao Fan
Xianhao Fan
Jiefeng LiuJiefeng Liu
Jiefeng Liu
JLJiaxi Li
Jiaxi Li
Frequency-domain spectroscopy (FDS) is demonstrated to be affected by electrode polarization and conductance behavior in the low-frequency ranges, which causes the unreliable prediction results of transformer cellulose insulation. In order to solve this issue, a fingerprint database based on the dielectric modulus is reported to predict the degree of polymerization (DP) and moisture content of cellulose insulation. In the current work, the relevant fingerprints that characterize the insulation conditions are obtained by studying the dielectric modulus curves of cellulose insulation with various insulation conditions, as well as the DC conductivity of transformer oil. Then, the dielectric modulus fingerprint database is established in the lab, and the accuracy of the reported fingerprint database is later verified. As a potential tool, the dielectric modulus fingerprint database is tested by several samples, and the results demonstrate that the accuracy of this method is more than 80%. In that respect, an interesting discovery of this paper is that the dielectric modulus fingerprint database may be a helpful tool for conditions prediction of the transformer cellulose insulation system.