Adam Łysiak

Mr. Adam Łysiak

Opole University of Technology
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2020 in Brain Sciences
Verified
Journal Article
Open access
PDF file
Szczepan PaszkielSzczepan Paszkiel
Szczepan Paszkiel
PDPaweł Dobrakowski
Paweł Dobrakowski
AŁAdam Łysiak
Adam Łysiak
Everyone experiences stress at certain times in their lives. This feeling can motivate, however, if it persists for a prolonged period, it leads to negative changes in the human body. Stress is characterized, among other things, by increased blood pressure, increased pulse and decreased alpha-frequency brainwave activity. An overview of the literature indicates that music therapy can be an effective and inexpensive method of improving these factors. The objective of this study was to analyze the impact of various types of music on stress level in subjects. The conducted experiment involved nine females, aged 22. All participants were healthy and did not have any neurological or psychiatric disorders. The test included four types of audio stimuli: silence (control sample), rap, relaxing music and music triggering an autonomous sensory meridian response (ASMR) phenomenon. The impact of individual sound types was assessed using data obtained from four sources: a fourteen-channel electroencephalograph, a blood pressure monitor, a pulsometer and participant’s subjective stress perception. The conclusions from the conducted study indicate that rap music negatively affects the reduction of stress level compared to the control group (p < 0.05), whereas relaxing music and ASMR calms subjects much faster than silence (p < 0.05).

3 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
AŁAdam Łysiak
Adam Łysiak
AFAnna Froń
Anna Froń
DBDawid Bączkowicz
Dawid Bączkowicz
Mirosław SzmajdaMirosław Szmajda
Mirosław Szmajda
Vibroarthrography (VAG) is a non-invasive and potentially widely available method supporting the joint diagnosis process. This research was conducted using VAG signals classified to five different condition classes: three stages of chondromalacia patellae, osteoarthritis, and control group (healthy knee joint). Ten new spectral features were proposed, distinguishing not only neighboring classes, but every class combination. Additionally, Frequency Range Maps were proposed as the frequency feature extraction visualization method. The results were compared to state-of-the-art frequency features using the Bhattacharyya coefficient and the set of ten different classification algorithms. All methods evaluating proposed features indicated the superiority of the new features compared to the state-of-the-art. In terms of Bhattacharyya coefficient, newly proposed features proved to be over 25% better, and the classification accuracy was on average 9% better.

11 February 2021 in IEEE Access
Verified
Journal Article
Open access
AŁAdam Łysiak
Adam Łysiak
Mirosław SzmajdaMirosław Szmajda
Mirosław Szmajda
One of the most important classification problems is selecting proper features, i.e. features that describe the classified object in the most straightforward way possible. Then, one of the biggest challenges of the feature selection is the evaluation of the feature’s quality. There is a plethora of feature evaluation methods in the literature. This paper presents the results of a comparison between nine selected feature evaluation methods, both existing in literature and newly defined. To make a comparison, features from ten various sets were evaluated by every method. Then, from every feature set, best subset (according to each method) was chosen. Those subsets then were used to train a set of classifiers (including decision trees and forests, linear discriminant analysis, naive Bayes, support vector machines, k nearest neighbors and an artificial neural network). The maximum accuracy of those classifiers, as well as the standard deviation between their accuracies, were used as a quality measures of each particular method. Furthermore, it was determined, which method is the most universal in terms of the data set, i.e. for which method, obtained accuracies were dependent on the feature set the least. Finally, computation time of each method was compared. Results indicated that for applications with limited computational power, method based on the average overlap between feature’s values seem best suited. It led to high accuracies and proved to be fast to compute. However, if the data set is known to be normally distributed, method based on two-sample ${t}$ -test may be preferable.

12 January 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AŁAdam Łysiak
Adam Łysiak
Szczepan PaszkielSzczepan Paszkiel
Szczepan Paszkiel
In this paper, a method of obtaining parameters of one-column Jansen–Rit model was proposed. Methods present in literature are focused on obtaining parameters in an on-line manner, producing a set of parameters for every point in time. The method described in this paper can provide one set of parameters for a whole, arbitrarily long signal. The procedure consists of obtaining specific frequency features, then minimizing mean square error of those features between the measured signal and the modeled signal, using genetic algorithm. This method produces an 8-element vector, which can be treated as an EEG signal feature vector specific for a person. The parameters which were being obtained are maximum postsynaptic potential amplitude, maximum inhibitory potential amplitude, ratio of the number of connections between particular neuron populations, the shape of a nonlinear function transforming the average membrane potential into the firing rate and the input noise range. The method shows high reproducibility (intraclass correlation coefficient for particular parameters ranging from 0.676 to 0.978) and accuracy (ranging from 0.662 to 0.863). It was additionally verified using EEG signal obtained for a single participant. This signal was measured using Emotiv EPOC+ NeuroHeadset.

1 January 2019 in IFAC-PapersOnLine
Verified
Journal Article
Closed access
AŁAdam Łysiak
Adam Łysiak
AFAnna Froń
Anna Froń
DBDawid Bączkowicz
Dawid Bączkowicz
MSMirosław Szmajda
Mirosław Szmajda

6 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
AŁAdam Łysiak
Adam Łysiak
TMTomasz Marciniak
Tomasz Marciniak
DBDawid Bączkowicz
Dawid Bączkowicz
Current research concerning the repeatability of the joint’s sounds examination in the temporomandibular joints (TMJ) is inconclusive; thus, the aim of this study was to investigate the repeatability of the specific features of the vibroarthrogram (VAG) in the TMJ using accelerometers. The joint sounds of both TMJs were measured with VAG accelerometers in two groups, study and control, each consisting of 47 participants (n = 94). Two VAG recording sessions consisted of 10 jaw open/close cycles guided by a metronome. The intraclass correlation coefficient (ICC) was calculated for seven VAG signal features. Additionally, a k-nearest-neighbors (KNN) classifier was defined and compared with a state-of-the-art method (joint vibration analysis (JVA) decision tree). ICC indicated excellent (for the integral below 300 Hz feature), good (total integral, integral above 300 Hz, and median frequency features), moderate (integral below to integral above 300 Hz ratio feature) and poor (peak amplitude feature) reliability. The accuracy scores for the KNN classifier (up to 0.81) were higher than those for the JVA decision tree (up to 0.60). The results of this study could open up a new field of research focused on the features of the vibroarthrogram in the context of the TMJ, further improving the diagnosing process.