Mi-ri Kwon

Dr. Mi-ri Kwon

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
JCJi Soo Choi
Ji Soo Choi
BHBoo-Kyung Han
Boo-Kyung Han
EKEun Sook Ko
Eun Sook Ko
JBJung Min Bae
Jung Min Bae
EKEun Sook Ko
Eun Sook Ko
SHSoo Yeon Hahn
Soo Yeon Hahn
Choi JS, et al. Korean J Radiol. 2019 Mar;20:e48. https://doi.org/10.3348/kjr.2018.0530

9 April 2020 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
MKMi-ri Kwon
Mi-ri Kwon
JSJung Hee Shin
Jung Hee Shin
Hyunjin ParkHyunjin Park
Hyunjin Park
HCHwan-ho Cho
Hwan-ho Cho
SHSoo Yeon Hahn
Soo Yeon Hahn
KPK.W. Park
K.W. Park
BACKGROUND AND PURPOSE: It is not known how radiomics using ultrasound images contribute to the detection of BRAF mutation. This study aimed to evaluate whether a radiomics study of gray-scale ultrasound can predict the presence or absence of B-Raf proto-oncogene, serine/threonine kinase (BRAF) mutation in papillary thyroid cancer. MATERIALS AND METHODS: The study retrospectively included 96 thyroid nodules that were surgically confirmed papillary thyroid cancers between January 2012 and June 2013. BRAF mutation was positive in 48 nodules and negative in 48 nodules. For analysis, ROIs from the nodules were demarcated manually on both longitudinal and transverse sonographic images. We extracted a total of 86 radiomics features derived from histogram parameters, gray-level co-occurrence matrix, intensity size zone matrix, and shape features. These features were used to build 3 different classifier models, including logistic regression, support vector machine, and random forest using 5-fold cross-validation. The performance including accuracy, sensitivity, specificity, positive predictive value, negative predictive value, and area under the receiver operating characteristic curve, of the different models was evaluated. RESULTS: The incidence of high-suspicion nodules diagnosed on ultrasound was higher in the BRAF mutation–positive group than in the mutation–negative group (P  = .004). The radiomics approach demonstrated that all classification models showed moderate performance for predicting the presence of BRAF mutation in papillary thyroid cancers with an area under the curve value of 0.651, accuracy of 64.3%, sensitivity of 66.8%, and specificity of 61.8%, on average, for the 3 models. CONCLUSIONS: Radiomics study using thyroid sonography is limited in predicting the BRAF mutation status of papillary thyroid carcinoma. Further studies will be needed to validate our results using various diagnostic methods.

1 April 2021 in Radiology
Verified
Journal Article
Closed access
MKMi-ri Kwon
Mi-ri Kwon
JCJi Soo Choi
Ji Soo Choi
HWHojeong Won
Hojeong Won
EKEun Sook Ko
Eun Sook Ko
EKEun Sook Ko
Eun Sook Ko
BHBoo-Kyung Han
Boo-Kyung Han
Screening outcome measures of abbreviated MRI were sustained without significant differences between 3 consecutive years, and all missed cancers were invasive but node negative and were at an early... Background Data are limited regarding the performance of abbreviated screening breast MRI during consecutive years and the characteristics of breast cancers missed and detected with it. Purpose To ...

22 April 2024 in Breast Cancer Research
Verified
Journal Article
Open access
PDF file
MKMi-ri Kwon
Mi-ri Kwon
YCYoosoo Chang
Yoosoo Chang
SHSoo-Youn Ham
Soo-Youn Ham
YCYoosun Cho
Yoosun Cho
EKEun Young Kim
Eun Young Kim
SRSeungho Ryu
Seungho Ryu
Background: Artificial intelligence (AI) algorithms for the independent assessment of screening mammograms have not been well established in a large screening cohort of Asian women. We compared the performance of screening digital mammography considering breast density, between radiologists and AI standalone detection among Korean women. Methods: We retrospectively included 89,855 Korean women who underwent their initial screening digital mammography from 2009 to 2020. Breast cancer within 12 months of the screening mammography was the reference standard, according to the National Cancer Registry. Lunit software was used to determine the probability of malignancy scores, with a cutoff of 10% for breast cancer detection. The AI’s performance was compared with that of the final Breast Imaging Reporting and Data System category, as recorded by breast radiologists. Breast density was classified into four categories (A–D) based on the radiologist and AI-based assessments. The performance metrics (cancer detection rate [CDR], sensitivity, specificity, positive predictive value [PPV], recall rate, and area under the receiver operating characteristic curve [AUC]) were compared across breast density categories. Results: Mean participant age was 43.5 ± 8.7 years; 143 breast cancer cases were identified within 12 months. The CDRs (1.1/1000 examination) and sensitivity values showed no significant differences between radiologist and AI-based results (69.9% [95% confidence interval [CI], 61.7–77.3] vs. 67.1% [95% CI, 58.8–74.8]). However, the AI algorithm showed better specificity (93.0% [95% CI, 92.9–93.2] vs. 77.6% [95% CI, 61.7–77.9]), PPV (1.5% [95% CI, 1.2–1.9] vs. 0.5% [95% CI, 0.4–0.6]), recall rate (7.1% [95% CI, 6.9–7.2] vs. 22.5% [95% CI, 22.2–22.7]), and AUC values (0.8 [95% CI, 0.76–0.84] vs. 0.74 [95% CI, 0.7–0.78]) (all P < 0.05). Radiologist and AI-based results showed the best performance in the non-dense category; the CDR and sensitivity were higher for radiologists in the heterogeneously dense category (P = 0.059). However, the specificity, PPV, and recall rate consistently favored AI-based results across all categories, including the extremely dense category. Conclusions: AI-based software showed slightly lower sensitivity, although the difference was not statistically significant. However, it outperformed radiologists in recall rate, specificity, PPV, and AUC, with disparities most prominent in extremely dense breast tissue.

Verified
Journal Article
Open access
PDF file
MKMi-ri Kwon
Mi-ri Kwon
JSJung Hee Shin
Jung Hee Shin
Hyunjin ParkHyunjin Park
Hyunjin Park
HCHwan-ho Cho
Hwan-ho Cho
EKEunjin Kim
Eunjin Kim
SHSoo Yeon Hahn
Soo Yeon Hahn
We aimed to evaluate whether radiomics analysis based on gray-scale ultrasound (US) can predict distant metastasis of follicular thyroid cancer (FTC). We retrospectively included 35 consecutive FTCs with distant metastases and 134 FTCs without distant metastasis. We extracted a total of 60 radiomics features derived from the first order, shape, gray-level cooccurrence matrix, and gray-level size zone matrix features using US imaging. A radiomics signature was generated using the least absolute shrinkage and selection operator and was used to train a support vector machine (SVM) classifier in five-fold cross-validation. The SVM classifier showed an area under the curve (AUC) of 0.90 on average on the test folds. Age, size, widely invasive histology, extrathyroidal extension, lymph node metastases on pathology, nodule-in-nodule appearance, marked hypoechogenicity, and rim calcification on the US were significantly more frequent among FTCs with distant metastasis compared to those without metastasis (p < 0.05). Radiomics signature and widely invasive histology were significantly associated with distant metastasis on multivariate analysis (p < 0.01 and p = 0.003). The classifier using the results of the multivariate analysis showed an AUC of 0.93. The radiomics signature from thyroid ultrasound is an independent biomarker for noninvasively predicting distant metastasis of FTC.

1 May 2023 in Radiology
Verified
Journal Article
Closed access
MKMi-ri Kwon
Mi-ri Kwon
JCJi Soo Choi
Ji Soo Choi
MLMi Yeon Lee
Mi Yeon Lee
SKSinae Kim
Sinae Kim
EKEun Sook Ko
Eun Sook Ko
BHBoo Kyung Han
Boo Kyung Han
Background Automated breast (AB) US effectively depicts mammographically occult breast cancers in Western women. However, few studies have focused on the outcome of supplemental AB US in Asian women who have denser breasts than Western women. Purpose To evaluate the performance of supplemental AB US on mammography-based breast cancer screening in Asian women with dense breasts and those with nondense breasts. Materials and Methods A retrospective database search identified asymptomatic Korean women who underwent digital mammography (DM) and supplemental AB US screening for breast cancer between January 2018 and December 2019. We excluded women without sufficient follow-up, established final diagnosis, or histopathologic results. Performance measures of DM alone and AB US combined with DM (hereafter AB US plus DM) were compared. The primary outcome was cancer detection rate (CDR), and the secondary outcomes were sensitivity and specificity. Subgroup analyses were performed based on mammography density. Results From 2785 screening examinations in 2301 women (mean age, 52 years ± 9 [SD]), 28 cancers were diagnosed (26 screening-detected cancers, two interval cancers). When compared with DM alone, AB US plus DM resulted in a higher CDR of 9.3 per 1000 examinations (95% CI: 7.7, 10.3) versus 6.5 per 1000 examinations (95% CI: 5.2, 7.2; P < .001) and a higher sensitivity of 90.9% (95% CI: 77.3, 100.0) versus 63.6% (95% CI: 40.9, 81.8; P < .001) but a lower specificity of 86.8% (95% CI: 85.2, 88.2) versus 94.6% (95% CI: 93.6, 95.5; P < .001) in women with dense breasts. In women with nondense breasts, AB US plus DM resulted in a higher CDR of 9.5 per 1000 examinations (95% CI: 7.1, 10.6) versus 6.3 per 1000 examinations (95% CI: 3.5, 7.1; P < .001), whereas specificity was lower at 95.2% (95% CI: 93.4, 96.8) versus 97.1% (95% CI: 95.8, 98.4; P < .001). Conclusion In Asian women, the addition of automated breast US to digital mammography showed higher cancer detection rates but lower specificities in both dense and nondense breasts. © RSNA, 2023 Supplemental material is available for this article.