Ziyuan Fan

Mr. Ziyuan Fan

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

29 May 2020 in Advances in Structural Engineering
Verified
Journal Article
Closed access
PDF file
ZFZiyuan Fan
Ziyuan Fan
QHQiao Huang
Qiao Huang
YRYuan Ren
Yuan Ren
ZZZhi-Yuan Zhu
Zhi-Yuan Zhu
XXXiang Xu
Xiang Xu
For long-span cable-stayed bridges, cables are one of the most important components to resist various actions. With the application of structural health monitoring technique, real-time recording of cable forces is achieved, and hence, the warning system on cable anomaly established. However, it is still difficult and there are challenges to conduct the warning system effectively, especially due to the phenomena of false alarm or omission. A practical reason is the warning index’s sensitivity to the ambient environment. Temperature variations, for instance, usually disturb the force-based cable anomaly warning and result in the false evaluation of structural condition. In view of eliminating the effects of environmental temperature, cointegration, a statistical concept from econometrics, is employed in cable anomaly warning studies. An approach that extracts warning index by linear combination of two non-stationary time series using the cointegration algorithm is developed in order to produce a more stationary cointegrated residual series (warning index series). The calculated stationary relationship between two time series is insensitive to the influence of environmental temperature and is capable of cable anomaly warning. Specifically, the framework of the cable anomaly warning system is first proposed. Subsequently, time-series test methods are introduced to check the non-stationary order and calculate the cointegration parameters of measured cable forces and environmental temperature. The computed cointegrated residual series is fed into statistical analysis as a warning index and the procedure of cable anomaly warning under the influence of environmental temperature is illustrated in detail. Finally, a case study for a cable-stayed bridge is demonstrated with results and discussions.

26 October 2022 in Structures
Verified
Journal Article
Closed access
YRYuan Ren
Yuan Ren
QYQiaowei Ye
Qiaowei Ye
XXXiang Xu
Xiang Xu
QHQiao Huang
Qiao Huang
ZFZiyuan Fan
Ziyuan Fan
WCWeijie Chang
Weijie Chang

20 January 2025 in Engineering Structures
Verified
Journal Article
Closed access
CDChao Deng
Chao Deng
YRYuan Ren
Yuan Ren
XXXiang Xu
Xiang Xu
ZFZiyuan Fan
Ziyuan Fan
QHQiao Huang
Qiao Huang

12 January 2024 in Advances in Bridge Engineering
Verified
Journal Article
Open access
PDF file
ZFZiyuan Fan
Ziyuan Fan
XTXiaoli Tang
Xiaoli Tang
YCYang Chen
Yang Chen
YRYuan Ren
Yuan Ren
CDChao Deng
Chao Deng
QHQiao Huang
Qiao Huang
During the life-cycle service of the constructed large span bridges, they face various threats every day due to the sophisticated operational environments. To ensure the structural safety, it is necessary to detect potential anomaly. Based on different inspection, monitoring and analysis technique, huge amounts of data that direct or indirect reflect structural characteristics can be obtained, and hence the anomaly detection methods developed. In order to provide a summary of relevant information needed by researchers to realize what is concerned about and how current practices deal with these issues, then further promote the application, this paper reviews understanding of anomaly detection in large span bridges. It starts with an analysis of concerned parameters, including dynamic and static structural parameters of a bridge. The various data sources are then commented. Next, existing anomaly detection methods are reviewed and classified. Finally, this paper concisely provides recent progress and discusses future research trends based on the identified knowledge gaps. We hope that this review will help development in this field.

31 March 2020 in Journal of Testing and Evaluation
Verified
Journal Article
Closed access
ZFZiyuan Fan
Ziyuan Fan
YSYongming Sun
Yongming Sun
The fatigue damage of concrete is an important reason for cracking and failure. To comprehensively study fatigue behaviors of concrete under uniaxial compression, cylindrical specimens with two different strength levels were made for cyclic loading tests. The evolution of fatigue process was detected via sensors, strain gages, and an X-ray computed tomography (CT) scanner. Parameters of fatigue life, deformation, internal cracks, and strength under different stress levels are analyzed based on measurements. The stress-cyclic number (S-N) equation is also given. Then, the fatigue damage parameter D is used to evaluate the status of damage. Additionally, a finite element modeling approach is developed based on the CT images to simulate the evolution of fatigue cracks within concrete specimens. With results of both macroscopic and microscopic analysis, the fatigue failure mechanism of concrete is expounded. The analysis results of this paper can provide a basis for the safety assessment for concrete structures.