As a passive sampling device, the polar organic chemical integrative sampler (POCIS) has the characteristics of simple operation, safety, and reliability for assessing the occurrence and risk of persistent and emerging trace organic pollutants. The POCIS, allowing for the determination of time-weighted average (TWA) concentration of polar organic chemicals, exhibits good application prospects in aquatic environments. Before deploying the device in water, the sampling rate (Rs), which is a key parameter for characterizing pollutant enrichment, should be determined and calibrated accurately. However, the Rs values strongly depend on experimental hydrodynamic conditions. This paper provides an overview of the current situation of the POCIS for environmental monitoring of organic pollutants in an aquatic system. The principle and theory of the POCIS are outlined. In particular, the effect factors such as the ambient conditions, pollutant properties, and device features on the Rs are analyzed in detail from aspects of impact dependence and mechanisms. The calibration methods of the Rs under laboratory and in situ conditions are summarized. This review offers supplementary information on comprehensive understanding of mechanism and application of the POCIS. Nevertheless, the Rs were impacted by a combined effect of solute–sorbent–membrane–solution, and the influence extent of each variable was still unclear. On this basis, the ongoing challenges are proposed for the future application of the POCIS in the actual environment, for instance, the need for this device to be improved in terms of quantitative methods for more accurate measurement of the Rs.
The localization of groundwater contaminant sources is the first and most fundamental step when dealing with site contamination problems. This paper presents a novel approach for groundwater pollution source identification in a site with low-velocity groundwater in which a strategy of an artificially enhanced catchment is adopted. The distance from a pumping well (artificial sink) to the source zone (unknown source) is calculated by integrating the concentration time series and well flow. Then, the orientation of the source well is delineated by applying the method of distance intersection. This method is suitable for an approximately homogeneous aquifer with average hydraulic conductivity ranging from 1 × 10−6 to 1 × 10−5 m/s and a contaminant whose transport process can be generalized to convective migration. The developed method was applied to an industrial contaminated site using three pumping wells and two observation wells. The results demonstrated that four potential source positions were identified. Among these, two positions situated near the production workshop were excluded by observation well responses. The remaining two positions located near the drain were identified as preferred treatment sources. Electrical prospecting showed source orientation consistent with the artificially enhanced catchment results. This proved that the method is effective and provides an alternative tool to help solve the problem of source identification in the first stage of remediation in sites with low-velocity groundwater.