This study investigates the performance of a cardiac-based seizure detection algorithm (CBSDA) that automatically triggers VNS (NCT01325623). Thirty-one patients with drug resistant epilepsy were evaluated in an epilepsy monitoring unit (EMU) to assess algorithm performance and near-term clinical benefit. Long-term efficacy and safety were evaluated with combined open and closed-loop VNS. Sixty-six seizures (n=16 patients) were available from the EMU for analysis. In 37 seizures (n=14 patients) a ≥ 20% heart rate increase was found and 11 (n=5 patients) were associated with ictal tachycardia (iTC, 55% or 35 bpm heart rate increase, minimum of 100 bpm). Multiple CBSDA settings achieved a sensitivity of ≥ 80%. False positives ranged from 0.5 to 7.2/h. 27/66 seizures were stimulated within ± 2 min of seizure onset. In 10/17 of these seizures, where triggered VNS overlapped with ongoing seizure activity, seizure activity stopped during stimulation. Physician-scored seizure severity (NHS3-scale) showed significant improvement for complex partial seizures (CPS) at EMU discharge and through 12 months (p<0.05). Patient-scored seizure severity (total SSQ score) showed significant improvement at 3 and 6 months. Quality of life (total QOLIE-31-P score) showed significant improvement at 12 months. The responder rate (≥ 50% reduction in seizure frequency) at 12 months was 29.6% (n=8/27). Safety profiles were comparable to prior VNS trials. The investigated CBSDA has a high sensitivity and an acceptable specificity for triggering VNS. Despite the moderate effects on seizure frequency, combined open- and closed-loop VNS may provide valuable improvements in seizure severity and QOL in refractory epilepsy patients.
Despite the widespread use of intraoperative electrocorticography (iECoG) during resective epilepsy surgery, there are conflicting data on its overall efficacy and inability to predict benefit per pathology. Given the heterogeneity of iECoG use in resective epilepsy surgery, it is important to assess the utility of interictal‐based iECoG. This individual patient data (IPD) meta‐analysis seeks to identify the benefit of iECoG during resective epilepsy surgery in achieving seizure freedom for various pathologies. Embase, Scopus, and PubMed were searched from inception to January 31, 2021 using the following terms: "ecog", "electrocorticography", and "epilepsy". Articles were included if they reported seizure freedom at ≥12‐month follow‐up in cohorts with and without iECoG for epilepsy surgery. Non‐English articles, noncomparative iECoG cohorts, and studies with <10% iECoG use were excluded. This meta‐analysis followed the PRISMA 2020 guidelines. The primary outcome was seizure freedom at last follow‐up and time to seizure recurrence, if applicable. Forest plots with random effects modeling assessed the relationship between iECoG use and seizure freedom. Cox regression of IPD was performed to identify predictors of longer duration of seizure freedom. Kaplan–Meier curves with log‐rank test were created to visualize differences in time to seizure recurrence. Of 7504 articles identified, 18 were included for study‐level analysis. iECoG was not associated with higher seizure freedom at the study level (relative risk = 1.09, 95% confidence interval [CI] = 0.96–1.23,p = .19,I2 = 64%), but on IPD (n = 7 studies, 231 patients) iECoG use was independently associated with more favorable seizure outcomes (hazard ratio = 0.47, 95% CI = .23–.95,p = .037). In Kaplan–Meier analysis of specific pathologies, iECoG use was significantly associated with longer seizure freedom only for focal cortical dysplasia (FCD;p < .001) etiology. Number needed to treat for iECoG was 8.8, and for iECoG in FCD it was 4.7. We show iECoG seizure freedom is not achieved uniformly across centers. iECoG is particularly beneficial for FCD etiology in improving seizure freedom.
Vagus nerve stimulation (VNS) therapy is associated with laryngeal muscle activation and induces voice modifications, well-known side effects of the therapy resulting from co-activation of the recurrent laryngeal nerve. In this study, we describe the non-invasive transcutaneous recording of laryngeal motor evoked potentials (LMEPs), which could serve as a biomarker of effective nerve activation and individual titration in patients with drug-resistant epilepsy. We recruited drug-resistant epileptic patients treated for at least 6 months with a VNS. Trains of 600–1200 VNS pulses were delivered with increasing current outputs. We placed six skin electrodes on the ventral surface of the neck, in order to record LMEPs whenever the laryngeal muscular threshold was reached. We studied the internal consistency and the variability of LMEP recordings, and compared different methods for amplitude calculation. Recruitment curves were built based on the stimulus–response relationship. We also determined the electrical axis of the LMEPs dipole in order to define the optimal electrode placement for LMEPs recording in a clinical setting. LMEPs were successfully recorded in 11/11 patients. The LMEPs threshold ranged from 0.25 to 1 mA (median 0.50 mA), and onset latency was between 5.37 and 8.77 ms. The signal-to-noise ratio was outstanding in 10/11 patients. In these cases, excellent reliability (Intraclass correlation coefficient, ICC > 0.90 across three different amplitude measurements) was achieved with 10 sample averages. Moreover, our recordings showed very good internal consistency (Cronbach’s alpha > 0.95 for 10 epochs). Area-under-the-curve and peak-to-peak measurement proved to be complementary methods for amplitude calculation. Finally, we determined that an optimal derivation requires only two recording electrodes, aligned on a horizontal axis around the laryngeal prominence. In conclusion, we describe here an optimal methodology for the recording of VNS-induced motor evoked responses from the larynx. Although further clinical validation is still necessary, LMEPs might be useful as a non-invasive marker of effective nerve activation, and as an aid for the clinician to perform a more rational titration of VNS parameters.
1 May 2020 in Seizure: European Journal of Epilepsy
Objective. To design and implement a setup for ex-vivo optical stimulation for exploring the effect of several key parameters (optical power and pulse duration), activation features (threshold, spatial selectivity) and recovery characteristics (repeated stimuli) in peripheral nerves. Approach. A nerve chamber allowing ex-vivo electrical and optical stimulation was designed and built. A 1470 nm light source was chosen to stimulate the nerve. A photodiode module was implemented for synchronization of the electrical and optical channels. Main results . Compound neural action potentials (CNAPs) were successfully generated with infrared light pulses of 200–2000 µ s duration and power in the range of 3–10 W. These parameters determine a radiant exposure for stimulation in the range 1.59–4.78 J cm −2 . Recruitment curves were obtained by increasing durations at a constant power level. Neural activation threshold is reached at a mean radiant exposure of 3.16 ± 0.68 J cm −2 and mean pulse energy of 3.79 ± 0.72 mJ. Repetition rates of 2–10 Hz have been explored. In eight out of ten sciatic nerves (SNs), repeated light stimuli induced a sensitization effect in that the CNAP amplitude progressively grows, representing an increasing number of recruited fibres. In two out of ten SNs, CNAPs were composed of a succession of peaks corresponding to different conduction velocities. Significance. The reported sensitization effect could shed light on the mechanism underlying infrared neurostimulation. Our results suggest that, in sharp contrast with electrical stimuli, optical pulses could recruit slow fibres early on. This more physiological order of recruitment opens the perspective for specific neuromodulation of fibre population who remained poorly accessible until now. Short high-power light pulses at wavelengths below 1.5 µ m offer interesting perspectives for neurostimulation.
Many epilepsy patients treated with vagus nerve stimulation additionally use an “on‐demand” function, triggering an extra stimulation to terminate a seizure or diminish its severity. Nevertheless, a substantial number of patients are not able to actively trigger stimulations by use of a magnet, due to the absence of an aura or inability for voluntary actions in the early phase of a seizure. To address this need, a novel implantable pulse generator, the AspireSR VNS system, was developed to provide automated ictal stimulation triggered by a seizure‐detecting algorithm. We report our experience with three patients in assessing the functionality of ictal stimulation, illustrating the detection system in practice. Detection of ictal tachycardia and variable additional detections of physiological tachycardia depended on the individual seizure‐detecting algorithm settings.