Introduction: Quantitative electrocardiographic (ECG) waveform analysis provides a noninvasive reflection of the metabolic milieu of the myocardium during resuscitation and is a potentially useful tool to optimize the defibrillation strategy. However, whether combining multiple ECG features can improve the capability of defibrillation outcome prediction in comparison to single feature analysis is still uncertain. Methods: A total of 3828 defibrillations from 1617 patients who experienced out-of-hospital cardiac arrest were analyzed. A 2.048-s ECG trace prior to each defibrillation without chest compressions was used for the analysis. Sixteen predictive features were optimized through the training dataset that included 2447 shocks from 1050 patients. Logistic regression, neural network and support vector machine were used to combine multiple features for the prediction of defibrillation outcome. Performance between single and combined predictive features were compared by area under receiver operating characteristic curve (AUC), sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and prediction accuracy (PA) on a validation dataset that consisted of 1381 shocks from 567 patients. Results: Among the single features, mean slope (MS) outperformed other methods with an AUC of 0.876. Combination of complementary features using neural network resulted in the highest AUC of 0.874 among the multifeature-based methods. Compared to MS, no statistical difference was observed in AUC, sensitivity, specificity, PPV, NPV and PA when multiple features were considered. Conclusions: In this large dataset, the amplitude-related features achieved better defibrillation outcome prediction capability than other features. Combinations of multiple electrical features did not further improve prediction performance.
Quantitative ventricular fibrillation (VF) waveform analysis is a potentially powerful tool to optimize defibrillation. However, whether combining VF features with additional attributes that related to the previous shock could enhance the prediction performance for subsequent shocks is still uncertain. A total of 528 defibrillation shocks from 199 patients experienced out-of-hospital cardiac arrest were analyzed in this study. VF waveform was quantified using amplitude spectrum area (AMSA) from defibrillator's ECG recordings prior to each shock. Combinations of AMSA with previous shock index (PSI) or/and change of AMSA (ΔAMSA) between successive shocks were exercised through a training dataset including 255shocks from 99patientswith neural networks. Performance of the combination methods were compared with AMSA based single feature prediction by area under receiver operating characteristic curve(AUC), sensitivity, positive predictive value (PPV), negative predictive value (NPV) and prediction accuracy (PA) through a validation dataset that was consisted of 273 shocks from 100patients. A total of61 (61.0%) patients required subsequent shocks (N = 173) in the validation dataset. Combining AMSA with PSI and ΔAMSA obtained highest AUC (0.904 vs. 0.819, p<0.001) among different combination approaches for subsequent shocks. Sensitivity (76.5% vs. 35.3%, p<0.001), NPV (90.2% vs. 76.9%, p = 0.007) and PA (86.1% vs. 74.0%, p = 0.005)were greatly improved compared with AMSA based single feature prediction with a threshold of 90% specificity. In this retrospective study, combining AMSA with previous shock information using neural networks greatly improves prediction performance of defibrillation outcome for subsequent shocks.
28 October 2022 in IEEE Transactions on Instrumentation and Measurement
Under low signal-to-noise-and-clutter ratio circumstances, non-contact multi-subjects vital sign assessment based on ultrawideband (UWB) radar is extremely difficult. It is challenging to obtain an accurate measurement since the respiratory frequency harmonics are mixed with noise during detection and are extremely near to the frequency of the heartbeat signal. We use an impulse radio ultrawideband (IR-UWB) radar and a stepped-frequency continuous-wave ultrawideband (SFCW-UWB) radar in measurement to get reliable vital signs from several participants. For adaptively extracting respiratory and heartbeat patterns, it is proposed to use the learning refined integral null space pursuit algorithm (LR-INSP), which is based on the learning refined integral null space pursuit method and optimum route learning. The refined-INSP technique aims to provide fine-grained multi-layer and multi-branch harmonic components. Then, to obtain a reliable and stable vital sign path from the multi-branch decomposition, an optimum path learning technique is presented. According to the experimental findings, the average signal accuracy assessment (SAA) of the heartbeat and respiratory frequencies for IR-UWB radar is 95.41% and 89.97%, respectively. The average SAA of the heartbeat and respiratory frequencies for SFCW-UWB radar is 94.39% and 99.48%, respectively.
22 November 2016 in IEEE Geoscience and Remote Sensing Letters
To overcome the contradiction between wide swath and high resolution in synthetic aperture radar systems, a multichannel azimuth reconstruction method is investigated to unambiguously recover the Doppler spectrum. The proposed method is derived from the least squares principle by exploiting a Vandermonde component of the system matrix. The Vandermonde matrix is Doppler independent and data independent. Reconstruction filter weightings can be easily achieved, and performance, including signal-to-noise ratio (SNR) and azimuth ambiguity-to-signal ratio, can be explicitly expressed. By well-conditioning the Vandermonde matrix and coherent processing of all channels, the proposed method improves the reconstruction performance. In simulated reconstruction, compared with the conventional matrix inversion method, the SNR increases by approximately 30 dB.