Helmut Telle

Prof. Dr. Helmut Telle

Departamento de Química Física Aplicada, Universidad Autónoma de Madrid, Campus de Cantoblanco, 28049 Madrid, Spain
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
MAMax Aker
Max Aker
KAKonrad Altenmüller
Konrad Altenmüller
ABArmen Beglarian
Armen Beglarian
JBJan Behrens
Jan Behrens
ABAnatoly Berlev
Anatoly Berlev
GZGenrich Zeller
Genrich Zeller
The Karlsruhe Tritium Neutrino (KATRIN) experiment aims at measuring the effective electron neutrino mass with a sensitivity of 0.2 eV/c2, i.e., improving on previous measurements by an order of magnitude. Neutrino mass data taking with KATRIN commenced in early 2019, and after only a few weeks of data recording, analysis of these data showed the success of KATRIN, improving on the known neutrino mass limit by a factor of about two. This success very much could be ascribed to the fact that most of the system components met, or even surpassed, the required specifications during long-term operation. Here, we report on the performance of the laser Raman (LARA) monitoring system which provides continuous high-precision information on the gas composition injected into the experiment’s windowless gaseous tritium source (WGTS), specifically on its isotopic purity of tritium—one of the key parameters required in the derivation of the electron neutrino mass. The concentrations cx for all six hydrogen isotopologues were monitored simultaneously, with a measurement precision for individual components of the order 10−3 or better throughout the complete KATRIN data taking campaigns to date. From these, the tritium purity, εT, is derived with precision of <10−3 and trueness of <3 × 10−3, being within and surpassing the actual requirements for KATRIN, respectively.

14 September 2021 in Sensors
Verified
Journal Article
Open access
PDF file
SNSimon Niemes
Simon Niemes
Helmut TelleHelmut Telle
Helmut Telle
BBBeate Bornschein
Beate Bornschein
LFLucian Fasselt
Lucian Fasselt
RGRobin Größle
Robin Größle
GZGenrich Zeller
Genrich Zeller
Highly accurate, quantitative analyses of mixtures of hydrogen isotopologues—both the stable species, H2, D2, and HD, and the radioactive species, T2, HT, and DT—are of great importance in fields as diverse as deuterium–tritium fusion, neutrino mass measurements using tritium β-decay, or for photonuclear experiments in which hydrogen–deuterium targets are used. In this publication we describe a production, handling, and analysis facility capable of fabricating well-defined gas samples, which may contain any of the stable and radioactive hydrogen isotopologues, with sub-percent accuracy for the relative species concentrations. The production is based on precise manometric gas mixing of H2, D2, and T2. The heteronuclear isotopologues HD, HT, and DT are generated via controlled, in-line catalytic reaction or by β-induced self-equilibration, respectively. The analysis was carried out using an in-line intensity- and wavelength-calibrated Raman spectroscopy system. This allows for continuous monitoring of the composition of the circulating gas during the self-equilibration or catalytic evolution phases. During all procedures, effects, such as exchange reactions with wall materials, were considered with care. Together with measurement statistics, these and other systematic effects were included in the determination of composition uncertainties of the generated reference gas samples. Measurement and calibration accuracy at the level of 1% was achieved.

11 September 2015 in Sensors
Verified
Journal Article
Open access
PDF file
SRSimone Rupp
Simone Rupp
AOAndreas Off
Andreas Off
HSHendrik Seitz-Moskaliuk
Hendrik Seitz-Moskaliuk
TJTimothy M. James
Timothy M. James
Helmut TelleHelmut Telle
Helmut Telle
Raman spectroscopy for low-pressure or trace gas analysis is rather challenging, in particular in process control applications requiring trace detection and real-time response; in general, enhancement techniques are required. One possible enhancement approach which enjoys increasing popularity makes use of an internally-reflective capillary as the gas cell. However, in the majority of cases, such capillary systems were often limited in their achievable sensitivity by a significant fluorescence background, which is generated as a consequence of interactions between the laser light and optical glass components in the setup. In order to understand and counteract these problems we have investigated a range of fluorescence-reducing measures, including the rearrangement of optical elements, and the replacement of glass components—including the capillary itself—by metal alternatives. These studies now have led to a capillary setup in which fluorescence is practically eliminated and substantial signal enhancement over standard Raman setups is achieved. With this improved (prototype) setup, detection limits of well below 1 mbar could be obtained in sub-second acquisition times, demonstrating the potential of capillary Raman spectroscopy for real-time, in situ gas sensing and process control applications, down to trace level concentrations.

25 September 2024 in Materials Horizons
Verified
Journal Article
Open access
PDF file
PWPeijiang Wang
Peijiang Wang
RMRafael Morales-Márquez
Rafael Morales-Márquez
GCGabriel Cervás
Gabriel Cervás
AMAlejandro Hernández Medel
Alejandro Hernández Medel
MOMarina Paris Ogayar
Marina Paris Ogayar
BJBeatriz H. Juárez
Beatriz H. Juárez
This study presents the synthesis of bright Ag 2 S-based nanocrystals, explores the temperature dependence of their photoluminescence quantum yield, and assesses their effectiveness in near-infrared subtissue imaging under mimicked conditions.

19 December 2022 in Sensors
Verified
Journal Article
Open access
PDF file
DBDeseada Diaz Barrero
Deseada Diaz Barrero
GZGenrich Zeller
Genrich Zeller
MSMagnus Schlösser
Magnus Schlösser
BBBeate Bornschein
Beate Bornschein
Helmut TelleHelmut Telle
Helmut Telle
Confocal Raman microscopic (CRM) imaging has evolved to become a key tool for spatially resolved, compositional analysis and imaging, down to the μm-scale, and nowadays one may choose between numerous commercial instruments. That notwithstanding, situations may arise which exclude the use of a commercial instrument, e.g., if the analysis involves toxic or radioactive samples/environments; one may not wish to render an expensive instrument unusable for other uses, due to contamination. Therefore, custom-designed CRM instrumentation—being adaptable to hazardous conditions and providing operational flexibility—may be beneficial. Here, we describe a CRM setup, which is constructed nearly in its entirety from off-the-shelf optomechanical and optical components. The original aim was to develop a CRM suitable for the investigation of samples exposed to tritium. For increased flexibility, the CRM system incorporates optical fiber coupling to both the Raman excitation laser and the spectrometer. Lateral raster scans and axial profiling of samples are facilitated by the use of a motorized xyz-translation assembly. Besides the description of the construction and alignment of the CRM system, we also provide (i) the experimental evaluation of system performance (such as, e.g., spatial resolution) and (ii) examples of Raman raster maps and axial profiles of selected thin-film samples (such as, e.g., graphene sheets).

27 March 2024 in Nanoscale Advances
Verified
Journal Article
Open access
PDF file
GZGenrich Zeller
Genrich Zeller
DBDesedea Díaz Barrero
Desedea Díaz Barrero
PWPaul Wiesen
Paul Wiesen
SNSimon Niemes
Simon Niemes
NTNancy Tuchscherer
Nancy Tuchscherer
Helmut TelleHelmut Telle
Helmut Telle
Graphene on a SiO2 (90 nm)/Si (550 μm) substrate is tritiated via self-radiolysis of tritium gas. The T-atoms generated by the β-decay of molecular T2 lose their excess energy by collisions so that they can form sp3 C–T bonds, generating T-graphene.