Aaron So

Dr. Aaron So


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
ASAaron So
Aaron So
SNSavvas Nicolaou
Savvas Nicolaou
So A, et al. Korean J Radiol. 2021 Jan;22(1):86-96. https://doi.org/10.3348/kjr.2020.0144

1 August 2012 in JACC: Cardiovascular Imaging
Verified
Journal Article
Closed access
ASAaron So
Aaron So
JHJiang Hsieh
Jiang Hsieh
YIYasuhiro Imai
Yasuhiro Imai
SNSuresh Narayanan
Suresh Narayanan
JKJohn Kramer
John Kramer
TLTing-Yim Lee
Ting-Yim Lee

1 September 2012 in Journal of Cardiovascular Computed Tomography
Verified
Journal Article
Closed access
ASAaron So
Aaron So
JHJiang Hsieh
Jiang Hsieh
SNSuresh Narayanan
Suresh Narayanan
JTJean-Baptiste Thibault
Jean-Baptiste Thibault
YIYasuhiro Imai
Yasuhiro Imai
TLTing-Yim Lee
Ting-Yim Lee

28 July 2016 in Medical Physics
Verified
Journal Article
Closed access
ASAaron So
Aaron So
YIYasuhiro Imai
Yasuhiro Imai
BNBrian Nett
Brian Nett
JJJohn Jackson
John Jackson
LNLiz Nett
Liz Nett
TLTing-Yim Lee
Ting-Yim Lee

1 September 2019 in Tomography
Verified
Journal Article
Open access
EEEsmaeil Enjilela
Esmaeil Enjilela
TLTing-Yim Lee
Ting-Yim Lee
GWGerald Wisenberg
Gerald Wisenberg
PTPatrick Teefy
Patrick Teefy
RBRodrigo Bagur
Rodrigo Bagur
ASAaron So
Aaron So
We investigated a projection interpolation method for reconstructing dynamic contrast-enhanced (DCE) heart images from undersampled x-ray projections with filtered backprojecton (FBP). This method may facilitate the application of sparse-view dynamic acquisition for ultralow-dose quantitative computed tomography (CT) myocardial perfusion (MP) imaging. We conducted CT perfusion studies on 5 pigs with a standard full-view acquisition protocol (984 projections). We reconstructed DCE heart images with FBP from all and a quarter of the measured projections evenly distributed over 360°. We interpolated the sparse-view (quarter) projections to a full-view setting using a cubic-spline interpolation method before applying FBP to reconstruct the DCE heart images (synthesized full-view). To generate MP maps, we used 3 sets of DCE heart images, and compared mean MP values and biases among the 3 protocols. Compared with synthesized full-view DCE images, sparse-view DCE images were more affected by streak artifacts arising from projection undersampling. Relative to the full-view protocol, mean bias in MP measurement associated with the sparse-view protocol was 10.0 mL/min/100 g (95%CI: −8.9 to 28.9), which was >3 times higher than that associated with the synthesized full-view protocol (3.3 mL/min/100 g, 95% CI: −6.7 to 13.2). The cubic-spline-view interpolation method improved MP measurement from DCE heart images reconstructed from only a quarter of the full projection set. This method can be used with the industry-standard FBP algorithm to reconstruct DCE images of the heart, and it can reduce the radiation dose of a whole-heart quantitative CT MP study to <2 mSv (at 8-cm coverage).

1 March 2018 in International Journal of Cardiology
Verified
Journal Article
Closed access
EEEsmaeil Enjilela
Esmaeil Enjilela
TLTing-Yim Lee
Ting-Yim Lee
JHJiang Hsieh
Jiang Hsieh
GWGerald Wisenberg
Gerald Wisenberg
PTPatrick Teefy
Patrick Teefy
ASAaron So
Aaron So