Xiaojun Duan

Dr. Xiaojun Duan

Southwest Hospital, Army Medical University

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 December 2020 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
KLKai Lei
Kai Lei
LLLi Ming Liu
Li Ming Liu
YXYi Xiang
Yi Xiang
XDXiaojun Duan
Xiaojun Duan
HFHua Quan Fan
Hua Quan Fan
LGLin Guo
Lin Guo
Purpose: To evaluate the operation and early clinical effect in primary total knee arthroplasty (TKA) about the novel combination of CT-based patient-specific three-dimensional (3D) preoperative design and conventional osteotomy instruments, compared with the conventional method.Methods: After a 1:1 propensity score-matching (PSM), patients were matched to the novel technique group and the conventional group, 109 cases in each group. The conventional group adopted a preoperative design based on a full-length radiograph (FLX) and received TKA with conventional osteotomy instruments. The novel technique group used a CT-based patient-specific 3D preoperative design combined with conventional osteotomy instruments; during the surgery, the femoral entry point, femoral valgus osteotomy angle, the fix point of tibial plateau extramedullary guide pin, and the position of tibial extramedullary positioning rod were accurately selected according to the preoperative 3D design to ensure accurate intraoperative implementation. The lower limb alignment, component position, operation time, tourniquet time, hospital stay, blood loss volume, incidence of postoperative complications, visual analog scale (Vas) score, and New Knee Society Score System (NEW-KSS) at 1 day before operation and 1, 6, and 12 months after operation were recorded and compared.Results: The novel technique group was significantly better than the conventional group in controlling lateral tibial component angle (LTC) (P< 0.001), and the novel technique group had lower percentages of hip-knee-ankle angle (HKA) outliers (P< 0.001) and overcorrection (P= 0.003). The operation time, tourniquet time, and hospital stay of the novel technique group was shorter (P< 0.05). In 1 month after the operation, the novel technique group achieved a significantly better VAS score (P< 0.05), but a similar NEW-KSS score (P> 0.05) when compared with the conventional group. But in 6 and 12 months after surgery, no statistical differences were seen in the above two scores (P> 0.05).Conclusion: The novel technique of CT-based patient-specific 3D preoperative design combined with conventional instruments can improve the accuracy of osteotomy in primary total knee arthroplasty, with benefits of significantly reducing pain and rapid recovery during the early postoperative period, but having no obvious effect on outcome after a 1-year follow-up.

26 January 2026 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
ZFZhenlan Fu
Zhenlan Fu
HFHuaquan Fan
Huaquan Fan
PWPuquan Wang
Puquan Wang
ZWZu Wan
Zu Wan
RXRan Xiong
Ran Xiong
LYLiu Yang
Liu Yang
To evaluate the clinical and radiographic results of a novel partial unicondylar arthroplasty (PUCA) using a three-dimensional-printed (3DP) porous tantalu