Professor and Chair, Department of Orthopaedic Surgery, University of Nebraska Medical Center, 985640 Nebraska Medical Center, Omaha, NE 68198-5640, USA
Dr. Kevin Garvin
Professor and Chair, Department of Orthopaedic Surgery, University of Nebraska Medical Center, 985640 Nebraska Medical Center, Omaha, NE 68198-5640, USA
Surgeons continually struggle to reduce orthopaedic infections, but no current treatment offers minimum side effects with maximum effectiveness. Antibiotics mixed in plaster of paris have been successful in treating large bony defects in patients with chronic osteomyelitis, and have the advantage of being well tolerated and absorbed by the body. Antibiotics impregnated in polymethylmethacrylate (PMMA) have offered local antibiotic delivery with some success. However, the effect of the antibiotic on the bone cement, the inconsistent elution of the antibiotic, and the need to remove the PMMA implant drives the need for a better system of antibiotic delivery. Polymers or copolymers of antibiotic-impregnated polylactic acid, polyglycolic acid or polyparadioxanone may provide an absorbable system for localized antibiotic delivery. Similar biodegradable systems used to treat small bone fractures have been successful with minimal side effects. In vitro studies have shown promising results of antibiotic elution from bioabsorbable microspheres and beads. Animal in vivo tests have shown that antibiotic impregnated polymers can successfully treat induced osteomyelitis in rabbits and dogs. These studies have provided consistent reproducible results, and now it is time to plan human trials to assess the efficacy of antibiotic microspheres implanted in infected bone and to plan in vivo and in vitro animal testing to investigate the feasibility of antibiotic-polymer-coated components.
F CT scans for this use has not been well documented. Questions/purposes The objective of this study was to determine the inter- and intraobserver reliability and the repeatability of the measurement of TKA component rotation using two-dimensional CT scans. Methods Fifty-two CT scans of TKAs being evaluated for revision surgery were measured by three different physicians. An orthopaedic resident and attending measured the same scans twice (more than 2 weeks apart) and a musculoskeletal radiologist measured them once. To assess interobserver reliability, intraclass correlation coefficients (ICCs) with two-way mixed-effects analysis of variance models as well as 95% confidence intervals for each were done. The repeatability coefficient was calculated as well, which is defined as the difference in measurements that include 95% of the values. This indicates the magnitude of variability among measurements in the same scale, which in this study is degrees. Results The interobserver ICC measurement for the femoral component was 0.386 (poor), and it was 0.670 (good) for the tibial component. The interobserver ICC for the combined rotation measurements was 0.617 (good). The intraobserver ICC for the femoral component was 0.606 (good), and it was 0.809 (very good) for the tibial component. The intraobserver ICC for combined rotation was 0.751 (good). The intraobserver repeatability coefficient for the femoral component was 0.49°, 10.64° for the tibial component, and 12.29° for combined rotation. Conclusions In this study, the inter- and intraobserver reliability, and the repeatability, of TKA component rotation were variable. This raises concern about whether CT scan is diagnostic in the assessment of component malrotation after TKA. Level of Evidence Level IV, diagnostic study. See Guidelines for Authors for a complete description of levels of evidence....
1 December 2015 in Clinical Orthopaedics and Related Research
Thylene because of its improved wear; however, limited information is available on the wear of HXLPE in this population, particularly the wear of HXLPE when it articulates with alternative bearings like Oxinium (Smith & Nephew, Memphis, TN, USA). Questions/purposes The purpose of this study was to evaluate two questions relative to this population of patients undergoing THA. First, what was the linear and volumetric wear rate of HXLPE in patients 50 years or younger at a minimum followup of 9 years and was osteolysis observed in any of these hips? Given the potential for damage to the Oxinium femoral head surface, was the wear of HXLPE in the patients with this material similar to the other bearings or was there accelerated or runaway wear that was visible in any of the patients? Methods From November 1999 to April 2005, 105 THAs were performed in 95 patients 50 years of age or younger (mean, 42 years; range, 20-50 years). The mean body mass index was 30 kg/m2 (range, 17-51 kg/m2).The mean followup was 12 years (range, 9-14 years). Two patients died, five patients (one bilateral) were lost to followup, and one hip was revised elsewhere for pain. The patients’ information was not included in the study, which left 87 patients with 96 hips for analysis. Highly crosslinked polyethylene was the acetabular bearing for all of the hips. We analyzed the linear and volumetric wear of all of the hips using the Martell method. Eighty hips had the same diameter head (28 mm) allowing us to more accurately compare the different bearing materials. The type of femoral head used was related to our sequential use of materials beginning with cobalt chrome (14), ceramic (23) followed by Oxinium (43) in the hips with 28-mm heads. Although cobalt-chrome was used early in this study, our previous experience with ceramic on polyethylene encouraged us to use it as an alternative bearing. The Oxinium was used consecutively for the remaining hips. Results The mean wear of the HXLPE after 1 year of bedding-in (true linear wear)was 0.022 mm/year (95% confidence interval [CI], 0.015-0.030 mm/year). The mean volumetric wear of HXLPE after 1 year of bedding-in (true volumetric wear) was 9 mm3/year (95% CI, 4-14 mm3/year). None of the hip radiographs had evidence of loosening or osteolysis. Wear was not associated with femoral head material (p = 0.58 for linear wear/year versus head material and p = 0.52 for volumetric wear/year versus head material). Conclusions In our study of patients 50 years of age or younger undergoing THA, the linear and volumetric wear rates of HXLPE were very low regardless of the bearing surface material. The laboratory concerns of Oxinium surface damage are serious but at this time we have not seen high wear of the HXLPE or osteolysis in this population. Level of Evidence Level III, therapeutic study....
1 November 2008 in Clinical Orthopaedics and Related Research
One of the assumed benefits of mobile bearings is the reduction of UHMWPE wear. However, to date, such benefit has not been categorically proven. To test the hypothesis that rotating platform total knee arthroplasty would have less wear than a fixed-bearing of the same design, this in vitro study compared the wear and kinematics (which influence wear) of one type of mobile with fixed-bearing tibial components of otherwise identical design. We tested four fixed bearing (FB) and four rotating platforms (RP) on force control knee simulators using identical ISO standard force inputs and simulated soft tissue restraint for 6 million walking cycles. The internal/external rotations peaked just before toe off, reaching an average maximum of 7° internal (tibial rotation) in the RP, 1.5 times that of the FB, which peaked at approximately 4.5° internally. Two of the RP specimens showed infrequent and mostly temporary dislocations of the UHMWPE insert. The wear rate for the FB averaged 8.14 ± 2.63 mg/million cycles and the RP averaged 6.78 ± 1.74 mg/million cycles. Both were very low wear rates compared with most other implants tested similarly in the same laboratory. We concluded polyethylene wear was similar for both designs.
1 December 2007 in Clinical Orthopaedics and Related Research
In the next 25 years, as the 37 million baby boomers age, we can expect a 400% increase in total joint arthroplasties that will challenge surgeons, the healthcare system, and the scientific community. The burden may be eased if we are able to manipulate side population stem cells and enhance peri-prosthetic bone remodeling thereby reducing the incidence of revisions. Therefore, as a preliminary question, we asked if the number and quality of side population stem cells, with the ability to proliferate into multiple cell lineages for long periods, correlates with age and can be evaluated in peripheral blood. Using flow cytometry we analyzed the quantity and quality of side population stem cells from bone marrow and peripheral blood in 54 patients (20 under 60 years of age, 34 over) undergoing THA. The total side population of stem cells decreased with age, but their long-term repopulating ability (quality) remained constant. The total count of side population stem cells in marrow correlated with the number found in peripheral blood. If these populations can be manipulated, periprosthetic remodeling may be beneficially enhanced.