Mihai Burlibasa

Mihai Burlibasa


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Corina Marilena CristacheCorina Marilena Cristache
Corina Marilena Cristache
Eugenia Eftimie TotuEugenia Eftimie Totu
Eugenia Eftimie Totu
GIGabriela Iorgulescu
Gabriela Iorgulescu
Aida PantaziAida Pantazi
Aida Pantazi
DDDorel Dorobantu
Dorel Dorobantu
MEMarius Enǎchescu
Marius Enǎchescu
The present study aimed to assess the eighteen month follow-up patient-centered outcomes of a simple and predictable protocol for 3D-printed functional complete dentures manufactured using an improved poly(methyl methacrylate) (PMMA)–nanoTiO2. A detailed morphological and structural characterization of the PMMA–TiO2 nanocomposite, using SEM, EDX, XRD, and AFM, after 3D-printing procedure and post-wearing micro-CT, was also performed. Methods: A total of 35 fully edentulous patients were enrolled in this prospective study. A 0.4% TiO2-nanoparticle-reinforced PMMA composite with improved mechanical strength, morphologically and structurally characterized, was used according to an additive computer-aided design and computer-aided manufacturing (CAD/CAM) protocol for complete denture fabrication. The protocol proposed involved a three-step appointment process. Before denture insertion, 1 week, 12 month, and 18-month follow up patients were evaluated via the Visual Analogue Scale (VAS, 0–10) and Oral Health Impact Profile for Edentulous Patients (OHIP-EDENT), with a higher score meaning poor quality of life. Results: A total of 45 complete denture sets were inserted. OHIP-EDENT scored significantly better after 18 months of denture wearing, 20.43 (±4.42) compared to 52.57 (±8.16) before treatment; mean VAS was improved for all parameters assessed. Conclusions: Within the limitations of this study, we can state that the proposed workflow with the improved material used is a viable treatment option for patients diagnosed with complete edentulism.

21 December 2012 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
Corina Marilena CristacheCorina Marilena Cristache
Corina Marilena Cristache
LMLigia Adriana Stanca Muntianu
Ligia Adriana Stanca Muntianu
MBMihai Burlibasa
Mihai Burlibasa
Andreea DidilescuAndreea Didilescu
Andreea Didilescu

6 November 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LOluminita oancea
luminita oancea
MBMihai Burlibasa
Mihai Burlibasa
APAlexandru Eugen Petre
Alexandru Eugen Petre
Eugenia PanaitescuEugenia Panaitescu
Eugenia Panaitescu
Corina Marilena CristacheCorina Marilena Cristache
Corina Marilena Cristache
(1) Background: Occlusal vertical dimension (OVD) in the optimal maxillo–mandibular relationship is an important parameter to establish when complex dental rehabilitation has to be done. The optimal method to measure OVD is still a challenge in everyday practice. The aim of the present study was to test the reliability of the correlation between OVD and some anthropometric and cephalometric methods described in the literature. The validity of OVD registration using a facial scanner was also assessed. (2) Materials and Methods: 150 dentate participants, aged 20–25 years, were randomly selected using sealed envelopes. Anthropometric measurements between specific standard points were performed: Subnasion–Prementon (Sn–PM) and Subnasion–Gnation (Sn–Gn) in maximum intercuspation and in the rest mandibular position, right and left pupil to the corresponding chelion. The cephalometric measurements registered were the lower facial angle and the angle between mandibular and Frankfurt planes. The distance Sn–Gn in maximum intercuspation was compared to all other parameters. Facial scanning, with a mobile phone and installed dedicated application, was performed on ten subjects, randomly selected using the same method among the participants, and the obtained 3D files were analyzed. The digital measurements were compared, for validity, to the clinical measurements. Pearson’s correlation coefficient was used, for comparing clinical Sn–Gn in maximum intercuspation position to the other parameters. (3) Results: A strong agreement between all measured anthropometric parameters of the facial scan and clinical contact measurement method was registered. None of the measured parameters could predict the exact OVD. (4) Conclusions: In the limits of our study, the facial scanning could be used for predictable registration of OVD and the stored digital information could be preserved through life and use for oral rehabilitation. However, if OVD needs to be determined, several measurement methods, including cephalometric measurements, need to be used simultaneously to reach a final decision.

15 March 2019 in Revista de Chimie
Verified
Journal Article
Closed access
CCCorina Marilena Cristache
Corina Marilena Cristache
Eugenia Eftimie TotuEugenia Eftimie Totu
Eugenia Eftimie Totu
AGAlexandra Raluca Grosu
Alexandra Raluca Grosu
OEOana Ene
Oana Ene
IBIrina Adriana Beuran
Irina Adriana Beuran
MBMihai Burlibasa
Mihai Burlibasa
The aim of the present study was to evidence the improved behavior of our modified PMMA-TiO2 nanocomposite material used to obtain 3D printed complete dentures. A protocol for long-term rapid prototyping complete denture manufacturing using our nanocomposite material, completely characterized and the evaluation of the clinical performance and complications after eighteen months of continuous wearing was also described. Thirty-five fully edentulous patients were enrolled in this prospective clinical study and forty-five complete dentures (31 maxillary and 14 mandibular) have been obtained using an additive manufacturing technology. Due to the good performances of the nanocomposite material, no major functional complications for the obtained medical devices occurred and the clinical outcomes for the 3D printed dentures were favorable evaluated at eighteen months follow up.

30 December 2018 in Materiale Plastice
Verified
Journal Article
Closed access
Eugenia Eftimie TotuEugenia Eftimie Totu
Eugenia Eftimie Totu
CCCorina Marilena Cristache
Corina Marilena Cristache
SISelim Isildak
Selim Isildak
OTOzlem Tavukcuoglu
Ozlem Tavukcuoglu
APAida Pantazi
Aida Pantazi
TTTiberiu Totu
Tiberiu Totu
The present paper is focused on analyzing if appropriate adhesion between the polymeric matrix and titania filler nanoparticles is obtained for the PMMA-TiO2 photo-curable dental material, suitable for application in RP - stereolithography (SLA) for complete denture manufacturing. It was found that different amounts, between 0.2% and 2.5 % (w/w%), of added titanium oxide nanoparticles slightly modify the structural behavior of the PMMA polymeric matrix. The material characterization was carried out using FT-IR and microscopy techniques.

1 January 2017
Verified
Journal Article
Closed access
CDConstantin Dăguci
Constantin Dăguci
MBMihai Burlibasa
Mihai Burlibasa
RMRuxandra Mărgărit
Ruxandra Mărgărit
LTLivia Alice Tănăsescu
Livia Alice Tănăsescu
LDLuminiţa Dăguci
Luminiţa Dăguci
OAOana Cella Andrei
Oana Cella Andrei