Susan Hagness

Susan Hagness

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2015 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
TCTimothy J. Colgan
Timothy J. Colgan
SHSusan Hagness
Susan Hagness
BVBarry D. Van Veen
Barry D. Van Veen
Objective: Conventional inverse-scattering algorithms for microwave breast imaging result in moderate resolution images with blurred boundaries between tissues. Recent 2-D numerical microwave imaging studies demonstrate that the use of a level set method preserves dielectric boundaries, resulting in a more accurate, higher resolution reconstruction of the dielectric properties distribution. Previously proposed level set algorithms are computationally expensive, and thus, impractical in 3-D. In this paper, we present a computationally tractable 3-D microwave imaging algorithm based on level sets. Methods: We reduce the computational cost of the level set method using a Jacobian matrix, rather than an adjoint method, to calculate Frechet derivatives. We demonstrate the feasibility of 3-D imaging using simulated array measurements from 3-D numerical breast phantoms. We evaluate performance by comparing full 3-D reconstructions to those from a conventional microwave imaging technique. We also quantitatively assess the efficacy of our algorithm in evaluating breast density. Results: Our reconstructions of 3-D numerical breast phantoms improve upon those of a conventional microwave imaging technique. The density estimates from our level set algorithm are more accurate than those of the conventional microwave imaging, and the accuracy is greater than that reported for mammographic density estimation. Conclusion: Our level set method leads to a feasible level of computational complexity for full 3-D imaging, and reconstructs the heterogeneous dielectric properties distribution of the breast more accurately than conventional microwave imaging methods. Significance: 3-D microwave breast imaging using a level set method is a promising low-cost, nonionizing alternative to current breast imaging techniques.

12 March 2020 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
YMYahya Mohtashami
Yahya Mohtashami
NBNader Behdad
Nader Behdad
SHSusan Hagness
Susan Hagness
We present a balun-free dipole antenna for generating localized heating patterns in microwave ablation. The dipole antenna is created by extending the outer and inner conductors of the coaxial cable. One dipole arm is a helical outer conductor encompassing the other arm that is the extended inner conductor. The overall lengths of the helix and the extended inner conductor are three quarters and one quarter of a wavelength, respectively. The helix’s current direction reverses a quarter of a wavelength away from the feed point, becoming aligned with the extended inner conductor’s current. This creates a relatively low input impedance, choking the current on the outer surface of the outer conductor. The fields produced by the currents flowing on the dipole arms destructively interfere closer to the feed point, while constructively interfering further from it. This helps the antenna produce nearly spherical ablation zones. A 1.9-GHz prototype of the antenna was fabricated and its ablation performance was experimentally verified in egg white. Measurement results showed good agreement with the simulations and confirmed the antenna’s effectiveness in generating localized ablation zones. Our proposed design can serve as a promising candidate for performing minimally invasive ablation therapy within flexible and maneuverable embodiments.

28 June 2012 in IEEE Transactions on Terahertz Science and Technology
Verified
Journal Article
Closed access
BYBenjamin B. Yang
Benjamin B. Yang
SKSarah L. Katz
Sarah L. Katz
KWKeely J. Willis
Keely J. Willis
MWMarcus J. Weber
Marcus J. Weber
IKIrena Knezevic
Irena Knezevic
JBJohn H. Booske
John H. Booske
The successful engineering of sources and components in the terahertz (THz) regime benefits from good characterization of materials properties. Previous research reports have shown that calculations of material parameters that are valid at radio frequencies are no longer accurate at THz frequencies. A high-quality-factor quasi-optical hemispherical resonator operating between 300 GHz-1 THz has been designed and implemented for the measurement of electronic properties of conductors as well as low-loss dielectrics. This apparatus is the first quasi-optical resonator to achieve Q≈ 4×105 at frequencies greater than 400 GHz in the THz regime. It is also the first open resonator designed to measure effective conductivity at these frequencies. This paper discusses the techniques that enabled high-Q operation in the THz regime. It also includes measurements of silicon with different doping densities and conductors of various surface roughness values with comparison to theoretical predictions.

22 March 2023 in PLOS ONE
Verified
Journal Article
Open access
PDF file
WCWendy C Crone
Wendy C Crone
PKPelin Kesebir
Pelin Kesebir
BHBeverly Hays
Beverly Hays
SMShilagh A Mirgain
Shilagh A Mirgain
RDRichard J Davidson
Richard J Davidson
SHSusan Hagness
Susan Hagness
The mental health crisis in graduate education combined with low treatment rates among engineering graduate students underscores the need for engineering graduate programs to provide effective methods to promote well-being. There is an extensive body of neuroscience research showing that contemplative practices, such as mindfulness, produce measurable effects on brain function and overall well-being. We hypothesized that a mindfulness-based training program designed for engineering graduate students would improve emotional well-being and, secondarily, enhance research capacity. An initial pilot study was conducted at a single institution (Phase 1), followed by a larger study conducted at both the original and a second institution (Phase 2) to gather additional data and show the program’s transferability. The program comprised eight weekly mindfulness training sessions. Individuals in the study were randomly assigned to either an intervention group or wait-list control group. We administered pre- and post-test surveys with quantitative measures designed to assess emotional and physical well-being, as well as creativity, research satisfaction, and desire to contribute to the betterment of society. Participants also completed a summative survey to evaluate the impact of the program on their well-being and research. Analysis revealed statistically significant findings: improved emotional health, decreased neuroticism, increased positive affect, decreased negative affect, and increased mindfulness in the intervention groups compared to the control groups. Intervention groups in Phase 2 also reported statistically significant improvement in satisfaction with their research. Our findings suggest that mindfulness training has the potential to play a vital professional and personal development role in graduate engineering education.

16 October 2018 in IEEE Antennas and Propagation Magazine
Verified
Journal Article
Closed access
YMYahya Mohtashami
Yahya Mohtashami
HLHung Luyen
Hung Luyen
JSJames F. Sawicki
James F. Sawicki
JSJacob D. Shea
Jacob D. Shea
NBNader Behdad
Nader Behdad
SHSusan Hagness
Susan Hagness

30 October 2020 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
YMYahya Mohtashami
Yahya Mohtashami
NBNader Behdad
Nader Behdad
SHSusan Hagness
Susan Hagness
Objective: In this study, we investigate the performance of a flexible microwave ablation antenna for generating localized ablation zones. Methods: We designed a helical dipole antenna to operate at 1.9 GHz in egg white and liver. Semi-rigid prototypes of the antenna were fabricated and used to perform ablation experiments in egg white and perfused liver. Pulsed and continuous-wave power deliveries at different power levels were used. Flexible prototypes of the antenna were fabricated and used to perform ex vivo ablation experiments in perfused liver. Results: Pulsing was effective in reducing the shaft heating of semi-rigid cables. The antenna was capable of producing substantial ablation zones in perfused liver. Typical diameters (perpendicular to the antenna axis) of generated ablation zones with semi-rigid antennas in egg white and perfused liver were 30 mm and 20 mm, respectively. The flexible antenna had a good impedance match while bent. Average diameter of generated ablation zones by the flexible antenna with 10-W continuous wave experiments in perfused liver was 26 mm. No significant difference was observed between the performances of semi-rigid and flexible prototypes. Conclusion: The flexible helical dipole antenna is capable of maintaining its good impedance match while bent and can generate substantial ablation zones in presence of perfusion. Significance: The proposed flexible antenna is promising for minimally invasive treatment of tumors that are otherwise inaccessible by rigid antennas. One example is lung where a catheter-based deployment of the flexible antenna into the tumor via airways may substantially reduce risks associated with using rigid antennas.