Mohammed Marie

Dr. Mohammed Marie


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 July 2015 in Sensors
Verified
Journal Article
Open access
PDF file
MMMohammed Marie
Mohammed Marie
SMSanghamitra Mandal
Sanghamitra Mandal
OMOmar Manasreh
Omar Manasreh
A glucose electrochemical sensor based on zinc oxide (ZnO) nanorods was investigated. The hydrothermal sol–gel growth method was utilized to grow ZnO nanorods on indium tin oxide-coated glass substrates. The total active area of the working electrode was 0.3 × 0.3 cm2 where titanium metal was deposited to enhance the contact. Well aligned hexagonal structured ZnO nanorods with a diameter from 68 to 116 nm were obtained. The excitonic peak obtained from the absorbance spectroscopy was observed at ~370 nm. The dominant peak of Raman spectroscopy measurement was at 440 cm−1, matching with the lattice vibration of ZnO. The uniform distribution of the GOx and Nafion membrane that has been done using spin coating technique at 4000 rotations per minute helps in enhancing the ion exchange and increasing the sensitivity of the fabricated electrochemical sensor. The amperometric response of the fabricated electrochemical sensor was 3 s. The obtained sensitivity of the fabricated ZnO electrochemical sensor was 10.911 mA/mM·cm2 and the lower limit of detection was 0.22 µM.

2 February 2018 in Nanotechnology
Verified
Journal Article
Closed access
PDF file
MMMohammed Marie
Mohammed Marie
AMAnishkumar Manoharan
Anishkumar Manoharan
AKAndrian V Kuchuk
Andrian V Kuchuk
SASimon Ang
Simon Ang
MMM O Manasreh
M O Manasreh
An enzyme-free glucose sensor based on vertically grown zinc oxide nanorods (NRs) functionalized with ferric oxide (Fe 2 O 3 ) is investigated. The well-aligned and high density ZnO NRs were synthesized on an FTO/glass substrate by a sol-gel and hydrothermal growth method. A dip-coating technique was utilized to modify the surface of the as-grown ZnO NRs with Fe 2 O 3 . The immobilized surface was coated with a layer of nafion membrane. The fabricated glucose sensor was characterized amperometrically at room temperature using three electrodes stationed in the phosphate buffer solution, where ZnO NRs/Fe 2 O 3 /nafion membrane was the sensing or working electrode, and platinum plate and silver/silver chloride were used as the counter and reference electrodes, respectively. The proposed non-enzymatic and modified glucose sensor exhibited a high sensitivity in the order of 0.052 μ A cm −2 (mg/dL) −1 , a lower detection limit of around 0.95 mmol L −1 , a sharp and fast response time of ∼1 s, and a linear response to changes in glucose concentrations from 100–400 mg dL −1 . The linear amperometric response of the sensor covers the physiological and clinical interest of glucose levels for diabetic patients. The device continues to function accurately after multiple measurements with a good reproducibility. The proposed glucose sensor is expected to be used clinically for in vivo monitoring of glucose.

26 January 2017 in Chemosensors
Verified
Journal Article
Open access
PDF file
MMMohammed Marie
Mohammed Marie
OMOmar Manasreh
Omar Manasreh
The influence of the as-grown zinc oxide nanorods (ZnO NRs) on the fabricated electrochemical sensor for in vitro glucose monitoring were investigated. A direct growth of ZnO NRs was performed on the Si/SiO2/Au electrode, using hydrothermal and sol-gel techniques at low temperatures. The structure, consisting of a Si/SiO2/Au/GOx/Nafion membrane, was considered as a baseline, and it was tested under several applied potential 0.1–0.8 V. The immobilized working electrode, with GOx and a nafion membrane, was characterized amperometrically using a source meter Keithely 2410, and an electrochemical impedance Gamry potentiostat. The sensor exhibited the following: a high sensitivity of ~0.468 mA/cm2 mM, a low detection limit in the order of 166.6 µM, and a fast and sharp response time of around 2 s. The highest sensitivity and the lowest limit of detection were obtained at 0.4 volt, after the growth of ZnO NRs. The highest net sensitivity was obtained after subtracting the sensitivity of the baseline, and it was in the order of 0.315 mA/cm2·mM. The device was tested with a range of glucose concentrations from 1–10 mM, showing a linear line from 3–8 mM, and the device was saturated after exceeding high concentrations of glucose. Such devices can be used for in vitro glucose monitoring, since glucose changes can be accurately detected.

4 February 2016 in MRS Advances
Verified
Journal Article
Closed access
PDF file
MMMohammed Marie
Mohammed Marie
SMSanghamitra Mandal
Sanghamitra Mandal
OMOmar Manasreh
Omar Manasreh

1 November 2021 in JMIR Formative Research
Verified
Journal Article
Open access
NANawal Faiez AlShehry
Nawal Faiez AlShehry
RSRaja Shanker
Raja Shanker
SZSyed Ziauddin A Zaidi
Syed Ziauddin A Zaidi
FAFahad AlGhmlas
Fahad AlGhmlas
IMIbraheem Hussein Motabi
Ibraheem Hussein Motabi
MAMusab Ahmed
Musab Ahmed
Background: The role of fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) in indolent lymphoma has been minimally studied. Objective: This study aims to assess the value of FDG-PET/CT in predicting the prognosis of indolent lymphoma. Methods: We prospectively recruited 42 patients with indolent lymphoma. A total of 2 patients were excluded, and 40 underwent baseline PET/CT and follow-up at various time points. A total of 9 patients were observed only, 7 received 4 doses of rituximab alone, and 24 received chemoimmunotherapy. Metabolic response on follow-up PET/CT was assessed using the maximum standardized uptake value (SUVmax) and Deauville criteria (DC). We aimed to obtain the best SUVmax and DC to predict optimal survival rates, risk stratification, and optimize therapeutic strategies. The mean follow-up from the initial diagnosis was 33.83 months. Results: SUVmax <4.35 at interim PET/CT provided the best discrimination, with a progression-free survival (PFS) of 100% and a median survival time of 106.67 months compared with SUVmax =4.35 (P=.04), which had a PFS of 43.8% and a median survival time of 50.17 months. This cutoff was also valuable in predicting overall survival at baseline, that is, 100% overall survival with baseline SUVmax <4.35, versus 58.4% for SUVmax =4.35 (P=.13). The overall survival of patients with a baseline DC score <3.0 was 100%, with a median overall survival of 106.67 months. Conclusions: We demonstrated the utility of PET/CT in indolent lymphomas. SUVmax (<4.35 vs =4.35) on interim PET/CT performed best in predicting PFS.