Yi Jia

Mr. Yi Jia

Kunming University of Technology

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FLFuhai Li
Fuhai Li
XQXiaojuan Quan
Xiaojuan Quan
YJYi Jia
Yi Jia
BWBo Wang
Bo Wang
GZGuibin Zhang
Guibin Zhang
SCSiyin Chen
Siyin Chen
This study analyzes the phenomenon of performance deterioration in fully grouted rock bolts in tunnels with a dry, hot environment and high geothermal activity with a focus on temperature effects on interfacial bond performance. Three groups of fully grouted rock bolt specimens were designed based on similar mechanical principles. They were produced and maintained at 20 °C, 35 °C, and 50 °C. Through the indoor gradual loading tensile test of specimens, variations of axial force and shear stress between the rock bolt and mortar adhesive interface were obtained under different environmental temperatures. Distribution of the axial force and shear stress on the anchorage section were found under different tensile forces. Results showed that, with an increase in specimen environmental temperature, maximum shear stress of the rock bolt section became smaller, while shear stress distribution along the rock bolt segment became more uniform. In addition, the axial force value at the same position along the pull end was greater, while axial stress along the anchorage’s length decayed faster. With an increase in tensile force under different temperatures, the axial force and maximum shear stress of rock bolt specimens along the anchorage section has a corresponding increase.

1 January 2017 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
YJYi Jia
Yi Jia
RZRenda Zhao
Renda Zhao
PLPing Liao
Ping Liao
FLFuhai Li
Fuhai Li
YYYuan Yuan
Yuan Yuan
SZShuang Zhou
Shuang Zhou
To study the mechanical property of fiber reinforced cementations composites influenced by the fiber length, quartz sand diameter, matrix of water cement ratio, volume fraction of fiber and magnesium acrylate solution. Several 40×40×160 mm standard test specimens, “8” specimens and long “8” specimens and 21 groups of fiber concrete specimens were fabricated. The flexural, compressive and uniaxial tensile strength were tested by using the bending resistance, compression resistance and electronic universal testing machine. The results show that flexural and compressive strength of fiber reinforced cementations composites increases along with the increase of quartz sand diameter, with the growth of the PVA fiber length increases; When the water-binder ratio is 0.25 and powder-binder ratio is 0.3, the PVA fiber content is 1.5% of the mass of cementations materials, there is a phenomenon of strain hardening; The addition of magnesium acrylate solution reduces the tensile strength of PVA fiber reinforced cementations composites, the tensile strength of the specimens in the curing age of 7d is decreased by about 21% and the specimens in curing age of 28d is decreased by more than 50%.

18 September 2023 in Buildings
Verified
Journal Article
Open access
PDF file
YJYi Jia
Yi Jia
CWChaokuan Wei
Chaokuan Wei
ZHZiqiu Huang
Ziqiu Huang
QLQi Li
Qi Li
PLPing Liao
Ping Liao
WLWencong Lin
Wencong Lin
To effectively control the stress state and spatial alignment of arch ribs in the cable hoisting construction of a long-span, concrete-filled, steel tube arch bridge and ensure the safety of the structure, it is necessary to calculate and determine the appropriate cable force. Based on the actual project of a double-span, concrete-filled, steel tubular arch bridge, the construction stage of the left span of the bridge from the beginning of construction to the closure is taken as an example. The linear control method of “quiet do not move” is adopted. Based on the principle that the vertical displacement of the front end of the installed segment caused by the self-weight of the new hoisting segment is equal to the vertical displacement of the front end of the previous segment caused by the tension of the new hoisting segment, the tension cable force is calculated by forward iteration. Finally, based on the theory of the stress-free state method, the ideal linear design of the structure was achieved. The results show that after the closure of the bridge, the error range of the cable tension force is −13.33–15.40% on the left bank and −8.37–11.00% on the right bank. The elevation error of the arch rib is −0.003–0.043 m on the left bank and −0.007–0.032 m on the right bank. The overall stress error of the bridge arch is ±7.0 MPa. The error between the theoretical value and the actual value is within the scope of the specification requirements, which meets the specification requirements. After the closure, the arch shape of the bridge meets the smooth requirements.

12 August 2020 in Metals
Verified
Journal Article
Open access
PDF file
PLPing Liao
Ping Liao
BQBing Qu
Bing Qu
YHYaolong Haung
Yaolong Haung
YJYi Jia
Yi Jia
YWYongbao Wang
Yongbao Wang
HZHaifeng Zhu
Haifeng Zhu
In recent years, various welded details with complex local structure, ambiguous fatigue performance have appeared in fully welded steel truss bridges, however, they are not covered in the current design specifications. In order to study the fatigue performance of revised cope-hole details, fatigue performance experiments were designed and carried out on three specimens of revised detail with the same dimensions but subjected to different stress amplitude. Local finite element model of the revised cope-hole detail was established for further stress analysis. The results of finite element analysis were basically consistent with the static test results at majority of measurement points. Based on the existing fatigue test data and fatigue strength of cope-hole details defined in Eurocode and JSSC design code, the fatigue performance of revised cope-hole details was evaluated. The S-N fitting curve with the failure probability of 2.3% was obtained from the fatigue experiment results. The fatigue stress amplitude was 59.5 MPa when fatigue loading cycle was 2 × 106. It can be concluded that the fatigue performance of revised cope-hole detail was better than that of previous welded detail, which indicated that the revised detail had a significant improvement.