After human spinal cord injury (SCI), motoneuron recruitment and firing rate during voluntary and involuntary contractions may be altered by changes in motoneuron excitability. Our aim was to compare F waves in single thenar motor units paralyzed by cervical SCI to those in uninjured controls because at the single-unit level F waves primarily reflect the intrinsic properties of the motoneuron and its initial segment. With intraneural motor axon stimulation, F waves were evident in all 4 participants with C4-level SCI, absent in 8 with C5 or C6 injury, and present in 6 of 12 Uninjured participants ( P < 0.001). The percentage of units that generated F waves differed across groups (C4: 30%, C5 or C6: 0%, Uninjured: 16%; P < 0.001). Mean (±SD) proximal axon conduction velocity was slower after C4 SCI [64 ± 4 m/s ( n = 6 units), Uninjured: 73 ± 8 m/s ( n = 7 units); P = 0.037]. Mean distal axon conduction velocity differed by group [C4: 40 ± 8 m/s ( n = 20 units), C5 or C6: 49 ± 9 m/s ( n = 28), Uninjured: 60 ± 7 m/s ( n = 45); P < 0.001]. Motor unit properties (EMG amplitude, twitch force) only differed after SCI ( P ≤ 0.004), not by injury level. Motor units with F waves had distal conduction velocities, M-wave amplitudes, and twitch forces that spanned the respective group range, indicating that units with heterogeneous properties produced F waves. Recording unitary F waves has shown that thenar motoneurons closer to the SCI (C5 or C6) have reduced excitability whereas those further away (C4) have increased excitability, which may exacerbate muscle spasms. This difference in motoneuron excitability may be related to the extent of membrane depolarization following SCI. NEW & NOTEWORTHY Unitary F waves were common in paralyzed thenar muscles of people who had a chronic spinal cord injury (SCI) at the C4 level compared with uninjured people, but F waves did not occur in people that had SCI at the C5 or C6 level. These results highlight that intrinsic motoneuron excitability depends, in part, on how close the motoneurons are to the site of the spinal injury, which could alter the generation and strength of voluntary and involuntary muscle contractions.
A surface electromyography (EMG) analysis was performed in this study to examine central neural and peripheral muscle changes after a spinal cord injury (SCI). A linear electrode array was used to record surface EMG signals from the biceps brachii (BB) in 15 SCI subjects and 14 matched healthy control subjects as they performed elbow flexor isometric contractions from 10% to 80% maximum voluntary contraction. Muscle fiber conduction velocity (MFCV) and BB EMG–force relation were examined. MFCV was found to be significantly slower in the SCI group than the control group, evident at all force levels. The BB EMG–force relation was well fit by quadratic functions in both groups. All healthy control EMG–force relations were best fit with positive quadratic coefficients. In contrast, the EMG–force relation in eight SCI subjects was best fit with negative quadratic coefficients, suggesting impaired EMG modulation at high forces. The alterations in MFCV and EMG–force relation after SCI suggest complex neuromuscular changes after SCI, including alterations in central neural drive and muscle properties.
Cerebral Palsy (CP) is a permanent disorder caused by a lesion to the developing brain that significantly impairs motor function. The neurophysiological mechanisms underlying motor impairment are not well understood. Specifically, few have addressed whether motoneuron or peripheral axon properties are altered in CP, even though disruption of descending inputs to the spinal cord may cause them to change. In the present study, we have compared nerve excitability properties in seven adults with CP and fourteen healthy controls using threshold tracking techniques by stimulating the median nerve at the wrist and recording the compound muscle action potential (CMAP) over the abductor pollicis brevis. The excitability properties in the CP subjects were found to be abnormal. Early and late depolarizing and hyperpolarizing threshold electrotonus was significantly larger (i.e., fanning out), and resting current-threshold (I/V) slope was smaller, in CP compared to control. In addition resting threshold and rheobase tended to be larger in CP. According to a modeling analysis of the data, an increase in leakage current under or through the myelin sheath, i.e., the Barrett-Barrett conductance (GBB), combined with a slight hyperpolarization of the resting membrane potential, best explained the group differences in excitability properties. There was a trend for those with greater impairment in gross motor function to have more abnormal axon properties. The findings indicate plasticity of motor axon properties far removed from the site of the lesion. We suspect that this plasticity is caused by disruption of descending inputs to the motoneurons at an early age around the time of their injury.