Tiago Alvarenga

Dr. Tiago Alvarenga

Federal University of Juiz de Fora
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Tiago AlvarengaTiago Alvarenga
Tiago Alvarenga
ACAlexandre Lima de Carvalho
Alexandre Lima de Carvalho
Leonardo De Mello HonórioLeonardo De Mello Honório
Leonardo De Mello Honório
ACAugusto Cerqueira
Augusto Cerqueira
LFLuciano Manhães de Andrade Filho
Luciano Manhães de Andrade Filho
RNRafael Antunes Nóbrega
Rafael Antunes Nóbrega
The prospect of growth of a railway system impacts both the network size and its occupation. Due to the overloaded infrastructure, it is necessary to increase reliability by adopting fast maintenance services to reach economic and security conditions. In this context, one major problem is the excessive friction caused by the wheels. This contingency may cause ruptures with severe consequences. While eddy’s current approaches are adequate to detect superficial damages in metal structures, there are still open challenges concerning automatic identification of rail defects. Herein, we propose an embedded system for online detection and location of rails defects based on eddy current. Moreover, we propose a new method to interpret eddy current signals by analyzing their wavelet transforms through a convolutional neural network. With this approach, the embedded system locates and classifies different types of anomalies, enabling an optimization of the railway maintenance plan. Field tests were performed, in which the rail anomalies were grouped in three classes: squids, weld and joints. The results showed a classification efficiency of ~98%, surpassing the most commonly used methods found in the literature.

1 October 2015 in Nuclear and Particle Physics Proceedings
Verified
Journal Article
Open access
JAJ.C. Anjos
J.C. Anjos
TAT. Abrahão
T. Abrahão
Tiago AlvarengaTiago Alvarenga
Tiago Alvarenga
LAL.P. Andrade
L.P. Andrade
GAG. Azzi
G. Azzi
SWS. Wagner
S. Wagner
We present the status of the Angra Neutrino Experiment, aimed at developing an antineutrino detector for monitoring nuclear reactor activity. The detector comprises a 1.42 m3 Gadolinium-Water Cerenkov target, surrounded by 50 cm of water shielding, placed inside a commercial container about 30 m from the reactor core, at the Angra II nuclear power plant, Brazil. The 4 GW thermal power of the Angra II reactor will provide a few thousand antineutrino interactions per day. The main challenge of the experiment is to overcome the very high cosmic ray induced background at sea level. The present text describes the construction status and simulations results

18 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Tiago AlvarengaTiago Alvarenga
Tiago Alvarenga
ACAugusto Cerqueira
Augusto Cerqueira
LFLuciano Manhães de Andrade Filho
Luciano Manhães de Andrade Filho
RNRafael Antunes Nóbrega
Rafael Antunes Nóbrega
Leonardo De Mello HonórioLeonardo De Mello Honório
Leonardo De Mello Honório
HVHenrique Veloso
Henrique Veloso
Railway track circuit failures can cause significant train delays and economic losses. A crucial point of the railway operation system is the corrective maintenance process. During this operation, the railway lines have the circulation of trains interrupted in the respective sector, where traffic restoration occurs only after completing the maintenance process. Depending on the cause and length of the track circuit, identifying and solving the problem may take a long time. A tool that assists in track circuit fault detection during an inspection adds agility and efficiency in its restoration and cost reduction. This paper presents a new method, based on frequency domain reflectometry, to diagnose and locate false occupancy failures of track circuits. Initially, simulations are performed considering simplified track circuit approximations to demonstrate the operation of the proposed method, where the fault position is estimated by identifying the null points and through non-linear regression on signal amplitude response. A field test is then carried out in a track circuit approximately 1500 m long to validate the proposed method. The results show that the proposed method can identify and estimate the fault location due to a short circuit between rails with high accuracy.

1 September 2016 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
Tiago AlvarengaTiago Alvarenga
Tiago Alvarenga
JAJ.C. Anjos
J.C. Anjos
GAG. Azzi
G. Azzi
ACA.S. Cerqueira
A.S. Cerqueira
PCP. Chimenti
P. Chimenti
SWS. Wagner
S. Wagner

9 October 2020 in IEEE Transactions on Intelligent Transportation Systems
Verified
Journal Article
Closed access
Tiago AlvarengaTiago Alvarenga
Tiago Alvarenga
RNRafael Antunes Nóbrega
Rafael Antunes Nóbrega
ACAugusto S. Cerqueira
Augusto S. Cerqueira
LFLuciano M. de Andrade Filho
Luciano M. de Andrade Filho
Leonardo De Mello HonórioLeonardo De Mello Honório
Leonardo De Mello Honório
RBRafael Batista
Rafael Batista
This work addresses the subject of preventive maintenance of railroads which has a considerable impact on the cost and safety of railway companies by proposing a new technique to detect concentrated regions of low impedance between rails along railway lines from a railroad inspection vehicle. Its methodology is based on the standing waves theory applied to transmission lines. Simulation and field measurements have been carried out in order to understand and validate such technique, and a compact measurement system has been designed and implemented producing field-testing results that clearly indicate its feasibility and effectiveness.

1 May 2014
Verified
Conference Paper
Closed access
Tiago AlvarengaTiago Alvarenga
Tiago Alvarenga
TDTony I. Dornelas
Tony I. Dornelas
DEDhiogo R. Esterce
Dhiogo R. Esterce
JVJose A. de C. Vieira
Jose A. de C. Vieira
RNRafael A. Nobrega
Rafael A. Nobrega
This document presents a performance assessment of digital filters applied to the signal arriving to the acquisition system of the Neutrinos-Angra Detector which is equipped with the PMT model R5912 by Hamamatsu. It is shown that the signal-to-noise ratio of the front-end output signal generated by single photoelectrons can be well enhanced, improving the detection efficiency for events of this kind. Some of the proposed filters will be designed to work as estimator of the peak amplitude value of the signal of interest. The considered filters will be described and the achieved results presented.