Electricity jurisdictions procure generation capacity requirements competitively which maintains investment flows into the electricity system infrastructure. The capacity market auction is one of such competitive capacity procurement methods. It is challenging to consider energy storage (ES) capacity offers in capacity markets due to complex capacity contribution characteristics and lack of explicit mechanisms to integrate them. However, ES capacity can be used to manage the system peak demand. ES can substitute for peaker plants, especially if the demand curve is kurtosis. This paper proposes novel ES capacity contribution formulae and a comprehensive capacity auction model which is designed to consider capacity offers including energy-limited technologies such as ES. After all offers are converted to unforced capacity (UCAP), their energy limitations do not affect bid selection in the market. The proposed novel ES UCAP computation formulae consider power capacity, energy capacity and operational attributes. The paper also presents the results of a case study with three capacity supply offers and a case study based on actual Ontario system data. A detailed sensitivity analysis is also included in the paper to show the validity of the proposed ES UCAP formulae in the auction model. The proposed formulae provide significant benefits in successfully procuring ES capacity offers.
28 December 2017 in IEEE Transactions on Power Systems
Optimal power flow (OPF) is an important power systems optimization tool. However, due to the inherent nonlinearity of the solution space, OPF methods may yield a local optimal solution, leading to economic loss. For this reason, OPF remains a major research topic. Changing power balance equations can change the solution space, alter solution time, and create a chance of reaching a better solution. In this paper, a new simple line-wise optimal power flow (LWOPF) formulation is proposed using line-wise power balance equations and solved using successive linear programming (SLP) technique. The study results on nine different test systems, up to a 9,241-bus real power system, show that the proposed method is accurate, provides monotonic convergence, scales well for large systems and is consistently faster, up to twice the speed of MATPOWER and other proven bus-wise SLP approaches to solve OPF.
29 March 2019 in IET Generation, Transmission & Distribution
The purpose of optimal power flow (OPF) is to optimise an objective function subject to a set of operating constraints. It remains an active research area because of using the bus‐wise power balance equations, which leads to a non‐linear solution space, resulting in OPF yielding local optimal solutions, thereby causing significant economic loss. In this study, first, a new line‐wise OPF (LWOPF) formulation is proposed. Thereafter, a maximum loadability factor, as a voltage collapse indicator, is derived and combined with LWOPF constraints to form a voltage stability constrained LWOPF (VSCLWOPF) model. As the line‐wise power balance equations are based upon the square of voltage magnitudes, it results in significant improvement in the solution space and lower‐order terms in all computational steps. The LWOPF and VSCLWOPF formulations, are solved using non‐linear optimisation technique, tested on several benchmark and real power systems. Results show that the proposed LWOPF is accurate, provides monotonic convergence, and scales well for large systems. It provides a better solution and is consistently faster, up to twice the speed of MATPOWER, due to reduced computational needs. Results of VSCLWOPF show that, for the same voltage stability level, the solution costs less than that obtained by classical bus‐wise OPF.
22 August 2022 in IEEE Transactions on Power Delivery
Conventional distribution system (DS) asset planning methods consider energy only from transmission systems (TS) and not from distributed energy resources (DER), leading to expensive plans. Newer transactive energy DS (TEDS) asset planning models, built on capacity market mechanisms, consider energy from both TS and DERs, leading to lower-cost plans and maximizing social welfare. However, in both methods the cost of higher reliability requirements for some users are socialized across all users, leading to lower social welfare. In this paper, a novel transactive energy capacity market (TECM) model is proposed for DS asset planning. It builds on TEDS incremental capacity auction models by provisioning for critical loads to bid and receive superior reliability as a service. The TECM model considers these reliability transactions, in addition, to selling energy transactions from TS and DERs, buying energy transactions from loads, and asset upgrade transactions from the network operator. The TECM model allows for islanded microgrids and network reconfiguration to maximize social welfare. The TECM model is assessed on several case studies, demonstrating that it achieves higher social welfare and a lower plan cost.
12 June 2024 in IEEE Open Access Journal of Power and Energy
By 2050, zero-carbon electric power systems will rely heavily on innumerable distributed energy resources (DERs), such as wind and solar. Accurate estimation of the aggregate connected DER capacity becomes pivotal in such a landscape. However, forecasting, power flow analysis, and optimization of feeders for operational decision-making by individually modeling each of these numerous renewables in the absence of complete information are operationally challenging and technically impractical. In response, we introduce a method to accurately estimate the aggregate capacities of the connected DERs on distribution feeders and a near-term forecasting method. Our proposal comprises: 1) a novel deep learning-based architecture with a few convolutional neural network and long short-term memory (CNN-LSTM) modules to represent feeder connected aggregate models of DERs and loads and associated training algorithms; 2) a method for estimating aggregate capacities of connected renewables and loads; and 3) a method for short-term (hourly) high-resolution forecasting. This step of estimation of the aggregate capacities of connected DERs, is a sequel to solving feeder hosting capacity problem. The method is tested using a North American utility feeder data, achieving an average accuracy of 95.56% for forecasting aggregate load power, 93.70% for feeder flow predictions, and 97.53% for estimating the aggregate capacity of DERs.