David Jenkins

Dr. David Jenkins

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2019 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Open access
MAMerlinda Andoni
Merlinda Andoni
Valentin RobuValentin Robu
Valentin Robu
David FlynnDavid Flynn
David Flynn
SASimone Abram
Simone Abram
DGDale Geach
Dale Geach
APAndrew Peacock
Andrew Peacock

8 September 2008 in IET Renewable Power Generation
Verified
Journal Article
Closed access
DJDavid Jenkins
David Jenkins
JFJ. Fletcher
J. Fletcher
DKD. Kane
D. Kane
Existing models of microgeneration systems with integrated lead–acid battery storage are combined with a battery lifetime algorithm to evaluate and predict suitable sized lead–acid battery storage for onsite energy capture. Three onsite generation portfolios are considered: rooftop photovoltaic (2.5 kW), micro-wind turbine (1.5 kW) and micro combined heat and power (1 kW). With no embedded energy storage, the dwelling exports energy when the microgeneration system generates excess power leading to a high level of generated export throughout the year. The impact that the size of installed battery has on the proportion of the generated export that is reserved onsite, along with the annual energy discharged per year by the energy store is assessed. In addition, the lifetime algorithm is utilised to predict corresponding lifetimes for the different scenarios of onsite generation and storage size, with design tables developed for expected cost and weight of batteries given a predicted generated export and lifetime specification. The results can be used to indicate optimum size batteries for using storage with onsite generation for domestic applications. The model facilitates the choice of battery size to meet a particular criteria, whether that be optimising size, cost and lifetime, reducing grid export or attempting to be self-sufficient. Suitable battery sizes are found to have lifetimes of 2–4 years for high production microgeneration scenarios. However, this is also found to be highly variable, depending on chosen microgeneration scenario and battery size.

1 January 2008 in Energy and Buildings
Verified
Journal Article
Closed access
APA.D. Peacock
A.D. Peacock
DJDavid Jenkins
David Jenkins
MAM. Ahadzi
M. Ahadzi
ABA. Berry
A. Berry
STS. Turan
S. Turan

1 July 2010 in Energy Policy
Verified
Journal Article
Closed access
APA.D. Peacock
A.D. Peacock
DJDavid Jenkins
David Jenkins
DKD. Kane
D. Kane

1 July 2003 in Building and Environment
Verified
Journal Article
Closed access
DJDavid Jenkins
David Jenkins
TMTariq Muneer
Tariq Muneer

9 September 2023 in Expert Systems with Applications
Verified
Journal Article
Open access
ALAshkan Lotfipoor
Ashkan Lotfipoor
Sandhya PatidarSandhya Patidar
Sandhya Patidar
DJDavid Jenkins
David Jenkins