Che-Yu Lin

Prof. Dr. Che-Yu Lin

National Taiwan University
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2021 in Materials
Verified
Journal Article
Open access
PDF file
CLChe-Yu Lin
Che-Yu Lin
Jiunn Horng KangJiunn Horng Kang
Jiunn Horng Kang
Mechanical properties are crucial parameters for scaffold design for bone tissue engineering; therefore, it is important to understand the definitions of the mechanical properties of bones and relevant analysis methods, such that tissue engineers can use this information to properly design the mechanical properties of scaffolds for bone tissue engineering. The main purpose of this article is to provide a review and practical guide to understand and analyze the mechanical properties of compact bone that can be defined and extracted from the stress–strain curve measured using uniaxial tensile test until failure. The typical stress–strain curve of compact bone measured using uniaxial tensile test until failure is a bilinear, monotonically increasing curve. The associated mechanical properties can be obtained by analyzing this bilinear stress–strain curve. In this article, a computer programming code for analyzing the bilinear stress–strain curve of compact bone for quantifying the associated mechanical properties is provided, such that the readers can use this computer code to perform the analysis directly. In addition to being applied to compact bone, the information provided by this article can also be applied to quantify the mechanical properties of any material having a bilinear stress–strain curve, such as a whole bone, some metals and biomaterials. The information provided by this article can be applied by tissue engineers, such that they can have a reference to properly design the mechanical properties of scaffolds for bone tissue engineering. The information can also be applied by researchers in biomechanics and orthopedics to compare the mechanical properties of bones in different physiological or pathological conditions.

6 February 2020 in Frontiers in Materials
Verified
Journal Article
Open access
PDF file
CLChe-Yu Lin
Che-Yu Lin
The standard linear solid model (SLSM) is a typical and useful model for analyzing stress relaxation and creep behaviors of viscoelastic solids for obtaining the corresponding viscoelastic properties. However, the analysis results cannot be directly compared to the parameters commonly adopted for defining the mechanical properties of viscoelastic solids in the finite element simulation package such as the modulus of elasticity (Ee) and the two parameters in the dimensionless form of the relaxation modulus (g and τ1). The purpose of this paper is to introduce an alternative form of SLSM in terms of Ee, g, and τ1 for characterizing stress relaxation and creep behaviors. A series of stress relaxation and creep curves with different Ee, g, and τ1 was simulated by finite element simulation. The derived alternative form of SLSM was used to curve fit the simulated stress relaxation and creep curves to obtain the corresponding values of Ee, g, and τ1. The results showed that the values of Ee, g, and τ1 obtained from the simulation were approximately equal to the theoretical ones (i.e., those set in the simulation), showing that the alternative form of SLSM can accurately evaluate the corresponding Ee, g, and τ1. In conclusion, the alternative form is formulated in terms of the parameters used to define the mechanical properties in the finite element simulation package, so that the parameters obtained by curve fitting can be directly compared to those set in the finite element simulation package. It was also found that the physical meaning of g is associated with the ratio of viscous fluids to solids of a viscoelastic solid.

23 May 2022 in Polymers
Verified
Journal Article
Open access
PDF file
CLChe-Yu Lin
Che-Yu Lin
YCYi Cheng Chen
Yi Cheng Chen
CLChen-Hsin Lin
Chen-Hsin Lin
Ke-Vin ChangKe-Vin Chang
Ke-Vin Chang
The viscoelastic properties of materials such as polymers can be quantitatively evaluated by measuring and analyzing the viscoelastic behaviors such as stress relaxation and creep. The standard linear solid model is a classical and commonly used mathematical model for analyzing stress relaxation and creep behaviors. Traditionally, the constitutive equations for analyzing stress relaxation and creep behaviors based on the standard linear solid model are derived using the assumption that the loading is a step function, implying that the loading rate used in the loading process of stress relaxation and creep tests is infinite. Using such constitutive equations may cause significant errors in analyses since the loading rate must be finite (no matter how fast it is) in a real stress relaxation or creep experiment. The purpose of this paper is to introduce the constitutive equations for analyzing stress relaxation and creep behaviors based on the standard linear solid model derived with a finite loading rate. The finite element computational simulation results demonstrate that the constitutive equations derived with a finite loading rate can produce accurate results in the evaluation of all viscoelastic parameters regardless of the loading rate in most cases. It is recommended that the constitutive equations derived with a finite loading rate should replace the traditional ones derived with an infinite loading rate to analyze stress relaxation and creep behaviors for quantitatively evaluating the viscoelastic properties of materials.

4 January 2023 in Mechanics of Advanced Materials and Structures
Verified
Journal Article
Open access
CLChe-Yu Lin
Che-Yu Lin
Despite the common use of the standard linear solid model (SLSM) in viscoelasticity, the physical significance as well as the difference between the Maxwell and Kelvin forms of SLSM are still not clear. This paper demonstrates that each parameter of those two models has its specific physical meaning, and introduces the relationships allowing the transformations between those parameters. Regardless of their physical significance, those two models are equivalent in terms of their mathematical properties. Hence, no matter which model is chosen, consistent analysis results can always be obtained as long as the physical meaning of each parameter is accurately interpreted.


5 August 2021 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
FCFang-Jung Chen
Fang-Jung Chen
Yu-Sheng HsiaoYu-Sheng Hsiao
Yu-Sheng Hsiao
ILI-Hsiang Liao
I-Hsiang Liao
CLChun-Ting Liu
Chun-Ting Liu
PWPo-I Wu
Po-I Wu
Jiashing YuJiashing Yu
Jiashing Yu
Conductive polymers (CPs) have received increasing attention as promising materials for studying electrophysiological signals in cell and tissue engineering. The combination of CPs with electrical stimulation (ES) could possibly enhance neurogenesis, osteogenesis, and myogenesis. To date, research has been prioritized on capitalizing CPs as two-dimensional (2D) structures for guiding the differentiation. In contrast, relatively little is conducted on the implementation of 3D conductive scaffolds. In this research, we report the synergic assembly of poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) and multi-walled carbon nanotubes (MWCNTs) as a biocompatible, electrically conductive, mechanically robust and structurally porous 3D scaffold. To showcase the bioelectronic utilization, a proof-of-concept demonstration of electrically stimulated cell culture under ES is conducted. The ES effects coupled with the 3D scaffold are promising on pheochromocytoma 12 (PC12), a neuronal cell line, and the ES effect on osteogenesis of human adipose-derived stem cells (hASC) was further studied. PC12 cultured on this PEDOT:PSS/MWCNT 3D scaffolds was induced to differentiate toward a more mature neuronal phenotype with the ES treatment. Furthermore, hASC osteogenesis could be highly promoted in this conductive scaffold with ES. Calcium deposition concentration and osteo-differentiated gene markers were significantly higher with ES. The facile assembly of 3D conductive scaffolds sheds light on both platforms for investigating the 3D microenvironment for electrophysiological simulation of cells and tissues under the ES treatment of in vivo tissue engineering.